QJ Series Vertical Deep Well Submersible Centrifugal Water Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Product overview :

 QJ series deep well submersible waterpumps are widely used in farm irrigation, sprinkler irrigation, getting water from well, water supply and drainage system for industrial and civil building, water diversion project in hilly and mountain areas water drainage project in at low-lying areas, water supply and drainage in urban and rural's mining enterprisesand various ther kinds of water conservancy facilities. Its features are that the Motor and pump are assembled into a whole, so that it is simple in structure, convenient to assemble and disassemble, easy to use and maintain safe to operate. Otherwise, it covers an small area and does not pollute water.

 

2. Operation parameters :

(1). Flow range : 10-500 m3/h

(2). Lift range : 10-600m

(3). Applicable well diameter : φ175-φ400mm

(4). Diameter scope:φ32—φ203mm;

(5).Temperature range: -15—100°C.

 

3. QJ using condition:

(1) 380V voltage deviation is no more than ±5%,frequency is 50HZ, three-phase power deviation is no more than ±1%.

(2) Motor cavity must be filled with water.

(3) The first stage impeller of the pump should be more than 2mm below the moving water surface,  pump unit should be less than 70m below the static water level.

(4) The distance from the motor bottom to well bottom must be more than 3m.

(5) Water temperature should be no more than 20°C.

(6) Sand content of the water ( by mass) should be no more than 0.01%.

(7) PH value of water 6.5-8.5.

(8) Hydrogen sulfide content of the water should be no more than 1.5mg/L.

(9). Chloride ion content of the water should be no more than 400mg/L.

(10). Water yield of water source should ensure the requirements of pump continuous working.

 

4. Material

Impeller: Cast iron HT200,or stainless steel

Pump bowl: Cast iron HT200,or stainless steel,such as ss304 ss3016

Pump shaft : Cold-drawn steel with chrome plating,or stainless steel SS304 SS316

Motor Seal: Rubber O-ring seal,mechanical seal

Motor regulating sleeve: Rubber

 

5. FAQ

(1).  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

(2).  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

(3).  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

QJ Series Vertical Deep Well Submersible Centrifugal Water Pump

QJ Series Vertical Deep Well Submersible Centrifugal Water Pump




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to select hydraulic pump?
3. efficiencyVolume efficiency, for hydraulic pumps, is the ratio of actual flow to theoretical flow. A hydraulic motor is the ratio of its theoretical flow to its actual flow.Mechanical efficiency, for hydraulic pumps, refers to the ratio of theoretical torque to actual input torque. The actual output torque of the hydraulic motor is theoretical torque to overcome the torque after friction, so the mechanical efficiency is the ratio of the actual output torque to the theoretical torque.
Q:Why should the pump be closed when the centrifugal pump is started?
On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
Q:What does centrifugal pump mean horizontally?
Centrifugal pump: centrifugal pump is a centrifugal force on the impeller rotates to transport liquid pump. Centrifugal pumps use the impeller to rotate and cause centrifugal motion of the water to work. The pump before starting to pump shell and the water pipe filled with water, and then start the motor, the pump shaft to drive the impeller and water do high-speed rotation, centrifugal water movement, was thrown to the outer edge of the impeller, the pressure water pipeline flow through the volute pump into the pump shell.
Q:How to select the fire pump?
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
What will happen then? The aquarium glass is an insulator. The water in the fish tank has the same potential as the live wire, and the fish is like a bird standing on the fire line. No electricity flows through their bodies, so they won't get electrocuted. But if you put your hands into the water, you will get an electric shock, because the line voltage through the water, then your body and the earth to form a loop, current flowing through your body you will get (of course, if you stand on the insulator does not get an electric shock)
Q:What is double hydraulic pump?
[double hydraulic pump] the same drive shaft drives the rotation of two pumps, which are connected together and driven by an electric motor. The suction port of the pump is common, and the oil pressure port is separated from each other. Pump output of two shares of flow can be used alone, can also be used in parallel. This pump, a pump can play the function of two pumps. For example, there are two pumps on the loader, a pump acting as the work, a pump acting as the steering, and the double linked pump can replace the functions of the two pumps. It works by coupling the two pumps at the same time.
Q:Advantages and disadvantages of centrifugal pumps?
Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
Q:How to calculate the motor power of metering pump?
Two Hydraulic power, metering pump rated flow (L/H) X, maximum pressure (Barg) / 36000 = kw
Q:Is vane pump good or gear pump good?
1) the reversible design of gear pumps can also usually reverse, but reverse after the suction port change, and the pump safety valve does not work; leaf pump is generally not allowed to reverse. 3) the single acting vane pump can be designed to change the eccentric distance by moving the stator at the constant speed, so as to achieve the purpose of variable direction.
Q:What is the difference between the ground pump and the pump in the commercial concrete?
Day pump: the pump and pipe will be placed in a position on the site, the pipe in the air like the crane arm

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range