Product Description:

1. Application of the pump:

1>  Clean Water without abrasive particles, non-aggressive liquid.

2>  Domestic use.

3>  In particular for delivering water in combination with small pressure sets and for irrigation.

4>  Installed in enclosed places, or at least protected against inclement weather.

 

2.  Operating conditions.

1> Suction lift up to 8m.

2> Liquid temperature up to +40

3> Ambient temperature up to +40

4> Max. working pressure: 6bar.

 

3.  Motor description:

1> 2-pole induction motor: 50Hz.

2> Insulation: Class B.

3> Protection:  IP44.

4> With capacitor and thermal overload protection.

 

4.  Material of the pumps:

1> Pump body: Cast Iron.

2> Motor bracket: Aluminum.

3> Impeller: Brass.

4> Shaft with rotor: Stainless steel or CS45#

5> Mechanical seal: Ceramic-Graphite.

6> Copper Winding.

 

5. Detailed specification for the pumps:

QB Series Peripheral Pump with Brass Impellers

6. FAQ

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.


QB Series Peripheral Pump with Brass Impellers

QB Series Peripheral Pump with Brass Impellers

QB Series Peripheral Pump with Brass Impellers




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q:What are the functions of a disposable infusion pump?
When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
Q:Why should the pump be closed when the centrifugal pump is started?
On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
Q:What are the parts of a pump? How do you classify it?I just want to know
The liquid ring pump: pumping air, the working medium is generally at room temperature water gas lift pump: simple structure of submersible sewage pump: a form of basic principle, performance parameters of centrifugal pump, with it the same. Underwater installation, sound, water cooling condition, screw pump: spiral lower invasion water medium variety formThere are too many kinds of pumps, such as submersible pumps for wells, centrifugal feed pumps, sewage pumps, etc. the submersible pumps are wet, oil immersed, etc.The water pump for automobiles is divided into oil lubrication and grease lubrication,
Q:What kind of motor does the hydraulic pump need?
Calculation of actual oil pump power:First count the flow: Q=dn L / minD displacement / revN RPM / minThen calculate the actual power: N=QP/ (60K) kwQ flow L / minP MPa MPaK total efficiency (usually 0.85)I do not know what the landlord said, 2.5L is the displacement or flow at the end, the concept must not be confused
Q:Which nuclear submarines use the shaftless pump technology?
The team led by academician Ma Weiming of China is now carrying out the research on this technology and has achieved initial success.. This technology is expected to be applied to the next generation of domestic submarines.
Q:Why is the submersible pump tripped on an electrical switch?
Submersible pump cable or motor insulation is damaged.3) motor water solution
Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system?
Valve control system is generally used for open systems, through the proportional valve or servo valve flow changes to control the motor or cylinder actuator action. The advantages of the system are energy saving, heat generation, and control accuracy. The disadvantage is that the system is complex and the cost is higher.
Q:What is the principle of a turbopump?
The working conditions of the turbine are different from those of the medium used, so the structure of the turbine is varied, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) mounted on a turbine shaft with blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work.
Q:Working principle and structure of external gear pump
The principle of the gear pump, gear pump structure consists of two gear mesh together with each other, and composed of pumps known as gear pumps. It relies on the gear teeth meshing space change in volume to transport the liquid, it belongs to the rotary pump, also can be considered as a volume pump. There are many kinds of gear pumps. According to the meshing mode, it can be divided into external gear pump and internal gear pump. According to the tooth shape of gear, it can be divided into positive gear pump, helical gear pump and herringbone gear pump.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range