PVC Tubes UPVC Drainage Pipes on Hot Sale with Good Quality
- Ref Price:
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 kg
- Supply Capability:
- 1000 kg/month
- OKorder Service Pledge
- Quality Product
- Order Online Tracking
- Timely Delivery
- OKorder Financial Service
- Credit Rating
- Credit Services
- Credit Purchasing
Specifications
pvc pipe for water drainage
1.Specification of pvc pipe:40mm-400mm
2.Thickness of pvc pipe:1.2mm-7.0mm
3.ISO certified.
Properties of pvc pipes:
1. Material: pvc pipe unplasticized polyvinyl chloride
2. Standard: GB, ISO9001, ISO14001
3. Color: white pvc pipe, grey pvc pipe , etc.
4. Specific Gravity, g/cm3, 20(C): 1.35 - 1.55
5. Vicat Softening Temperature, (C) >=79
6. Longitudinal Reversion, %, 150(C) <=5< span="">
7. Dichloromethane Resistance Test: No attack
8. Falling Weight Impact Test, TIR, %, 0(C) <=10< span="">
9. Tensile Yield Strength, Mpa >=40
10. Fitness of Water Tightness Test: No Leakage
11. Fitness of Air Tightness Test: No Leakage
Features of pvc pipes :
1) Light weight, easy to load and unload: PVC pipe is very light, convenient to handle loading unloading, and installing.
2) Good chemicals and drugs resistance: PVC pipe has its excellent resistance to the erosion caused by acids and alkalines, a great help to the chemical industries.
3) Small resistance to fluidity: The smooth surface reduces resistance to the fluids. Its roughness coefficient is only 0.009, much less than other pipes, Under same discharges, smaller cabibre of the pipe can be uesd.
4) Strong mechanical strength: Good resistance to water pressure, outside impact and pressure, is satisfied under any conditions.
5) Good electrical insulation: excellent insulation nature against electricity. the pvc pipe can be served as conduits and pipes in construction cable and wire.
6) Water quality unaffected: The solution tests on the PVC pipe show no affect on water quality when the water flows through is. It is considered the best piping material for running water works.
7) Simple installation: Very easy to connect, thus much time and laborcost may be saved.
Application of pvc pipes:
1) Structure Engineering, home water supply and drainage |
Specifications of the pvc pipe:
Outer Diameter (mm) | Wall thickness(mm) | |||||||
2.5MPA | 2.0MPA | 1.6MPA | 1.25MPA | 1.0MPA | 0.8MPA | 0.63MPA | ||
φ20 | 20*2.3 | 20*2.0 | ||||||
φ25 | 25*2.8 | 25*2.3 | 25*2.0 | |||||
Φ32 | 32*3.6 | 32*2.9 | 32*2.4 | 32*2.0 | ||||
Φ40 | 40*4.5 | 40*3.7 | 40*3.0 | 40*2.4 | 40*2.0 | |||
Φ50 | 50*5.6 | 50*4.6 | 50*3.7 | 50*3.0 | 50*2.4 | 50*2.0 | ||
Φ63 | 63*7.1 | 63*5.8 | 63*4.7 | 63*3.8 | 63*3.0 | 63*2.5 | 63*2.0 | |
Φ75 | 75*8.4 | 75*6.9 | 75*5.6 | 75*4.5 | 75*3.6 | 75*2.9 | 75*2.3 | |
Φ90 | 90*10.1 | 90*8.2 | 90*6.7 | 90*5.4 | 90*4.3 | 90*3.5 | 90*2.8 | |
Φ110 | 110*10.0 | 110*8.1 | 110*6.6 | 110*5.3 | 110*4.2 | 110*3.4 | 110*2.7 | |
Φ125 | 125*11.4 | 125*9.2 | 125*7.4 | 125*6.0 | 125*4.8 | 125*3.9 | 125*3.1 | |
Φ140 | 140*12.7 | 140*10.3 | 140*8.3 | 140*6.7 | 140*5.4 | 140*4.3 | 140*3.5 | |
Φ160 | 160*14.6 | 160*11.8 | 160*9.5 | 160*7.7 | 160*6.2 | 160*4.9 | 160*4.0 | |
Φ180 | 180*16.4 | 180*13.3 | 180*10.7 | 180*8.6 | 180*6.9 | 180*5.5 | 180*4.4 | |
Φ200 | 200*18.2 | 200*14.7 | 200*11.9 | 200*9.6 | 200*7.7 | 200*6.2 | 200*4.9 | |
Φ250 | 250*11.9 | 250*9.6 | 250*7.7 | 250*6.2 | ||||
Φ315 | 315*15.0 | 315*12.1 | 315*9.7 | 315*7.7 | ||||
Φ400 | 400*19.6 | 400*15.3 | 400*12.3 | 400*9.8 | ||||
- Q:
- Yes, plastic tubes can be used for cold-fill applications.
- Q:
- Yes, plastic tubes are generally resistant to abrasion.
- Q:
- No, plastic tubes are generally not microwave-safe as they can melt or release harmful chemicals when exposed to high temperatures. It is recommended to use microwave-safe materials such as glass or ceramic when heating food or liquids in the microwave.
- Q:incase i needed antibiotics and the nurse had a technician take my bloodpressure and i told him and he saw how i ahd that lil plastic tube in my vein incease i needed antiobiotics and i said shouldnt you do it on the other arm and he was like no its ok and he cecekd my blodd pressure while i ahd that in my vein is that really ok to do that??????????????? cus later she checked my blood pressure again ten mintues after he did that and it was only 70 and later when i left the hospital i was so dixxy and felt imparied but they also gave me adovine a anti anxiety could that habe made me dizzzy? was it ok that he checked my blood prssuere witht hat in my vein?
- It's OK he checked the blood pressure with that in your vein. I don't know that I would have done it on that arm, but it's ok. As long as it didn't swell up you're fine. Ativan is the drug and it will more than likely make you sleepy and dizzy. Blood pressure is also measured with two numbers. For example 120/80. If you had a lower number (diastolic) of 70 that's perfectly healthy.
- Q:Which companies manufacture GOOD QUALITY plastic and rubber tubing for use in a molecular biology lab, ie. for condensers, circulators, etc
- Tygon is a brand name for a variety of flexible tubing. Tygon is a registered trademark of Saint-Gobain Corporation. It is an invented word, owned and used by Saint-Gobain and originated in the late 1930s. Tygon is produced in 3 countries but sold throughout the world. Tygon Tubing is used in many markets including food and beverage, chemical processing, industrial, laboratory, medical, pharmaceutical, and semiconductor processing. There are many formulations of clear, flexible, Tygon tubing. The chemical resistance and physical properties vary among the different formulations. See link for types and suppliers.
- Q:i am designing something that has a frame of tubing that its relaxed when there is no air pressure in it, but becomes straight and reletivley rigid when when you put air presure in it.
- The 2 foot diameter nylon sleeves filled with low pressure air that you see for advertising displays. If you try to use small diameter tubing, with flexible plastic tubing, it won't work. The closest tubing that does work is specially made for pressure gauges, and it just slightly uncoils under pressure.
- Q:I have a 16 month old girl who has her first ear infection now. She has it in both ears and still has it even after her medicine was done. We have an appointment with an ear, nose and throat specialist for this Thursday, and I will be asking him the following questions.. But I also wanted to hear from people that went through this with their child. I understand that ear tubes probably won't be necessary because this is her first time with an ear infection. What exactly are ear tubes? How are they put in? What are the pros and cons of having them? I have heard that in the long run, they can cause more damage than good. And how did you soothe your little one while they were having difficulty sleeping at night?Thanks!!
- Ear Tubes Toddlers
- Q:PR plastic tubes, everyone said, permanent, a great harm to health, even drinking water is a problem?
- According to the main characteristics of PPR pipe, it is non-toxic and sanitary. PP-R has only carbon and hydrogen elements and no harmful toxic elements. It is hygienic and reliable. It is used not only for hot and cold water pipelines, but also for clean drinking water systems.
- Q:
- Yes, plastic tubes are safe for pharmaceutical products. They are commonly used in the industry due to their durability, flexibility, and ability to protect the contents from contamination. Additionally, plastic tubes can be made from various materials that comply with strict safety regulations and standards.
- Q:
- Yes, plastic tubes can be used for dispensing liquids. They are commonly used in various industries and applications such as in medical settings, laboratories, and household products for dispensing liquids like lotions, creams, and various liquids.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Similar products
New products
Hot products
You Might Also Like