PVC insulated , heavy steel wire armored, PVC sheathed coal mine power cable

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Product Details:

Detailed Product Description

 

1. Flexible rubber sheathed Power Cable of Rated Voltage Up To And including 10kV For Coal Mine 
2.We are manufacturer

Product Standard:
The product applies for A.C supply & distribution system and is manufactured according to State Coal industry standard MT818.12-1999.

Working conditions:
Max. allowable continuous operating temperature of conductor: 70°C.

Max. temperature of conductor during cutting-out shall not exceed 160°C(max. duration 5S).

Type and Description:

Type

Description

MVV

PVC insulated ,PVC sheathed power cable for coal mine

MVV22

PVC insulated , steel tape armored , PVC sheathed power cable for coal mine

MVV32

PVC insulated , fine steel wire armored, PVC sheathed power cable for coal mine

MVV42

PVC insulated , heavy steel wire armored, PVC sheathed power cable for coal mine

 Cable Specifications:

 

 

Type

 

Cores

    Rated Voltage  kV

0.6/1

1.8/3

3.6/6  6/6  6/10

    Nominal cross-section  mm²

MVV

3

1.5~300

10~300

10~300

MVV22

3

2.5~300

10~300

10~300

MVV32

3

16~300

MVV42

3

16~300

MVV

3+1

4~300

10~300

MVV22

3+1

4~300

10~300

MVV

4

4~185

4~185

MVV22

4

4~185

4~185

 

Nominal Thickness of Insulation:

 

 

Nominal cross sectional area of conductor
mm²

     Rated Voltage   kV

0.6/1

1.8/3

3.6/6

6/6   6/10

  mm
Nominal Thickness of Insulation

1.5

0.8

2.5

0.8

4

1.0

6

1.0

10

1.0

2.2

3.4

4.0

 

 

 

We supply cable, power cable, power wire, electric cable, electrical cable,xlpe insulated cable, xlpe insulated power cable, pvc cable, pvc power cable, xlpe cable, xlpe power cable, pe sheathed cable, pe sheathed power cable, insulated cable   


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:3 plugs plug the wire, black brown yellow how to pick up the wire 2
To the big home 粻 chu gang band to see the color of the Ji Ji shopping mall to buy a few dollars HDMI1.4 high-definition line can do, there is no need to buy a few hundred dollars, HDMI high-definition line is one meter each, Of course there are long,
Q:A floor wiring between the three switches, need a few patch panels, patch panels how many mouth?
Shake table (insulation resistance table) Our company is the choice of 2500V2500M Europe can be
Q:Who can look at the construction of the electrogram how to embed the tube? The more detailed the better Thank you
YJV is copper core XLPE insulated, PVC sheathed cable, laying in the room, tunnels and pipes, can not bear the mechanical pressure Core long-term allowable operating temperature shall not exceed 80 degrees Celsius, the ambient temperature of not less than -15 degrees Celsius under the conditions of laying without heating VV cable should not be used at -15 ℃ Cross-linked polyethylene insulated cable (YJV) with the cross-section of the current carrying capacity than the VV cable, and YJV cable mechanical properties than the VV cable, the application range than the VV cable wide Second, the two in the production equipment and process manufacturing are also different: VV for the plastic cable, YJV that cross-linked cable, the insulation performance is better than plastic cable YJV only made a cross-linking treatment on the insulating material to improve the heat-resistant temperature, while VV did not YJV cable operating temperature of 90 degrees, while the VV is only 70 degrees, with the cross-sectional area YJV cable carrying capacity VV class cable conductor running the maximum rated temperature of 70 degrees Celsius, short circuit (duration less than 5 seconds) the maximum temperature does not exceed 160 degrees Celsius YJV class cable conductor running the maximum rated temperature of 90 degrees Celsius, short circuit (duration less than 5 seconds) the maximum temperature does not exceed 250 degrees Celsius YJV is better than VV in the long run (long life), but more expensive than VV From the maximum allowable short circuit to see: YJV is 250 degrees, VV is 140
Q:Hanging Bathroom ceiling, the wire did not wear pipe. What should the standard cable be?
Digital cable set-top boxes generally have two different sets of cable is a three-color line connection, a group of HDMI high-definition line connection, how can a group can use, and now the TV should have two interfaces, the old TV Machine should also have a three-color line interface,
Q:What are the important parameters of the cable flame retardant casing? What are the criteria for flame retardant sleeves used in pump cables?
PBX out is not 110 wiring line. And the building of the phone points for the jumper on it.
Q:Office table below the line chaos into a group often stumbled feet, there is no kind of envelope tube ah.
1 insulation detection, with a shake table .2 internal resistance, with the length of the
Q:Can the camera be installed in the car after reversing the image?
the history allows the well-balanced door to install the drive device
Q:What is the flame retardant cable, high voltage cabinet to the transformer between the cables do not flame retardant?
In the past, the old house, the calculation of electricity load can not meet the needs of modern household electricity, and many use of aluminum, aluminum wire resistance than the large, large load naturally easy to heat, easy to aging. Proposed as follows: . the home distribution box to be replaced with the installation of air leakage with a protective device, if the use of the fuse is best to change the reliability of maintenance is not very good; . lighting, general socket, . easy to produce leakage of the location such as: kitchen, toilet socket must be three-phase four-wire cable . if you do not want too much trouble can choose to take the line outside the deduction of the buckle, the kitchen, toilet, . in general, with 1.5 square meters of lighting, socket with 2.5 square, air conditioning with 4 square copper is enough to use, but also to the wall, Electricity safety is a big deal, no matter who lives this house can not ignore this problem, remember.
Q:Building wiring, what needs the material, generally go to where to buy ?? !!!!!!
Cable tray installation CAD drawings: If you do not understand anything, please see the following cable tray design specifications;
Q:On the issue of electric water heaters, wires and waterways
Philips 43-inch PUF6701 / T3 installation of the set-top box method:

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range