Specifications of PVC Insulated Electrical Wire/Cable with Bare Copper Conductor
PVC sheath solid conductor electrical wire
ISO 9001-2008
Voltage: 450/750V
Cross section:1.0mm2 to 500mm2
OEM acceptance
Solid copper conductor 1.5mm 2.5mm 4mm 6mm electrical wire and cable
1.electrical wire is usually PVC insulated wire
PVC insulation no-sheathed general purpose electrical wire,single core,solid
2.sheathed round wires:
copper(aluminum)conductor pvc insulated pvc sheathed solid wires
copper(aluminum)conductor pvc insulated pvc sheathed flexible wires
Sizes:0.5-185mm2
3.products can be produced and provided accroding to standard G/T5023,IEC60227,BS6004,JB8734.
Standard:
GB/T5023.1-1997 450/750V or below PVC insulated electric wires.
GB/T5023.1-1997 is identical to IEC227,models are the same,can be produced according to customers requirement.
Using purpose:
4. used for AC rated voltage 450/750V and below for the followings:
lighting,electrical installation,the connection between instrumention and telecomunication equipment
Technical Data Sheet of PVC Insulated Electrical Wire/Cable with Bare Copper Conductor
Class 2 Conductor
Nominal | Conductor | Nominal | Max overall | Condcutor | Weight | ||
Cu | Al | Cu | Al | ||||
1.5 | 1/1.38 | 0.7 | 3.3 | 12.1 | - | 19.2 | - |
2.5 | 1/1.78 | 0.8 | 3.9 | 7.41 | 11.8 | 30.8 | 15.0 |
4 | 1/2.25 | 0.8 | 4.4 | 4.61 | 7.39 | 45.5 | 21.0 |
6 | 1/2.76 | 0.8 | 4.9 | 3.08 | 4.91 | 65.0 | 29.0 |
10 | 7/1.35 | 1.0 | 7.0 | 1.83 | 3.08 | 110.0 | 52.0 |
16 | 7/1.70 | 1.0 | 8.0 | 1.15 | 1.91 | 170.0 | 70.0 |
25 | 7/2.14 | 1.2 | 10.0 | 0.727 | 1.20 | 270.0 | 110.0 |
35 | 7/2.52 | 1.2 | 11.5 | 0.524 | 0.868 | 364.0 | 150.0 |
50 | 19/1.78 | 1.4 | 13.0 | 0.387 | 0.641 | 500.0 | 200.0 |
70 | 19/2.14 | 1.4 | 15.0 | 0.268 | 0.443 | 688.0 | 269.0 |
95 | 19/2.52 | 1.6 | 17.5 | 0.193 | 0.320 | 953.0 | 360.0 |
120 | 37/2.03 | 1.6 | 19.0 | 0.153 | 0.253 | 1168.0 | 449.0 |
150 | 37/2.25 | 1.8 | 21.0 | 0.124 | 0.206 | 1466.0 | 551.0 |
185 | 37/2.52 | 2.0 | 32.5 | 0.099 | 0.164 | 1808.0 | 668.0 |
Class 5 Conductor of PVC Insulated Electrical Wire/Cable with Bare Copper Conductor
Nominal | Conductor | Nominal | Max overall | Condcutor | Min insulated | Weight |
2.5 | 9/0.41 | 0.8 | 4.2 | 7.41 | 0.011 | 33.0 |
4 | 19/0.52 | 0.8 | 4.8 | 4.61 | 0.009 | 48.0 |
6 | 19/0.64 | 0.8 | 5.6 | 3.08 | 0.0084 | 68.0 |
10 | 49/0.52 | 1.0 | 7.6 | 1.83 | 0.0072 | 115.0 |
16 | 49/0.64 | 1.0 | 8.8 | 1.15 | 0.0062 | 176.0 |
25 | 98/0.58 | 1.2 | 11.0 | 0.727 | 0.0058 | 272.0 |
35 | 133/0.58 | 1.2 | 12.5 | 0.524 | 0.0052 | 384.0 |
50 | 133/0.68 | 1.4 | 16.5 | 0.387 | 0.0051 | 510.0 |
70 | 189/0.68 | 1.4 | 16.5 | 0.268 | 0.0045 | 714.0 |
95 | 259/0.68 | 1. | 19.5 | 0.139 | 0.0035 | 965.0 |
120 | 259/0.76 | 1.8 | 22.0 | 0.153 | 0.0032 | 1210.0 |
150 | 259/0.85 | 1.8 | 25.0 | 0.124 | 0.0032 | 1510.0 |
Pictures of PVC Insulated Electrical Wire/Cable with Bare Copper Conductor
- Q:The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
- What do you want to do? Do network cabling buried? Or in the building after the tube?
- Q:Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
- Wipe with water that day. You can also use ink thinner
- Q:Apple phone display cable or accessories not certified how to do
- Indicating that your Apple data cable is not original, no effect, re-plug the general and you can use the.
- Q:IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
- You are not very clear: how to start again? 300μF capacitor is normal? If the sound is normal (very small) after no-load start, the cable and the motor temperature are normal, the coil can be judged to be normal
- Q:I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
- There must be no room for consultation I did not have to do for seven years lazy they want to do nothing irresponsible
- Q:What is the difference between the WDZ wire and cable, the ZR wire cable and the NH wire and cable, and what kind of wire and cable should be used?
- Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria.............................................
- Q:Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
- There are [the top of the machine can be broken off the ball can be hit by Jiu turtle snow box video output cable and DVD video output line] into a junction box, and then through the sub-box toggle switch to select the 'set-top box' or 'DVD'; This junction box outputs a wire connection device or is connected to a TV.
- Q:How are various wire and cable models named?
- Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
- Q:Apple 6 Charging Why always show this cable has not yet been certified
- And I answered the other person's question is very similar: . the line of the banding distance of not more than 1.2 meters, the two ends of the wire box outlet tube 15CM should be ligation; . casing embedded, then through the basement wall, the surface must be installed rigid Waterproof casing, that is, steel pipe + water ring; through the fire pool, living pool: flexible waterproof casing; (wing ring specific practices can be collected online related Atlas); through the floor, according to whether the design requirements , Under normal circumstances PVC casing on it. Note: . rigid waterproof casing, flexible waterproof casing is a one-time reserved in place, through the floor of the casing of the flower lamb to suppress the barge of Xi Jie Xi Xi shou, is the first stay hole, when the installation of riser Casing, because the floor casing has every layer, the location of the reservation will always be biased, in order to ensure vertical vertical pipe, and finally unified hanging line repair hole and then install the riser and casing. . now most of the bathroom are dirty, waste and diversion, and more of the riser, and so on, the air conditioning casing of all the shear wall should be embedded, to avoid the subsequent damage to the structure of drilling (no stay can only drill) Note that the location of the hole and the installation of the riser will affect the opening of the toilet window. . the casing is the casing, riser is the riser, casing than the riser model 1 to 2 level. . plate at the end of flat, board 2 to 5CM higher to see if you need to do leveling layer.
- Q:IPhone6 This cable or accessories have not been certified how to solve
- Labor costs you can and workers to discuss, and some labor costs are calculated in accordance with square meters, and some are calculated in accordance with the day, the specific or ask the local construction team
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
PVC Insulated Electrical Wire/Cable with Bare Copper Conductor
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches