Professional Pvc Sheathed Copper Installation Cables

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
50000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

cnbm

Model Number:

VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV

Insulation Material:

PVC or XLPE

Type:

Low,Medium and High Voltage

Application:

s electric power distribution networks or industrial installations

Conductor Material:

Copper or Aluminium

Jacket:

PVC or PE

Filler:

Non-hygroscopic Polypropylene(PP)

Binder Tape:

Non-woven fabric

Metallic Armour 1:

Galvanized Stainless Steel Tape Armour(STA)

Metallic Armour 2:

Galvanized Stainless Steel Wire Armour(SWA)

Metallic Armour 3:

Non-magnetic Steel Tape Armour(only for single core)

Metallic Armour 4:

Aluminium Wire



Packaging & Delivery

Packaging Details:wooden drum; iron-wooden drum or steel drum
Delivery Detail:Depending on the quantity

Specifications

2015 new product electric power cable 
1 Conductor:Copper or Aluminium 
2 Insulation:PVC or XLPE 
3 Voltage:Low/Medium/High Vol

2015 new product electric power  cable  

Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

Professional Pvc Sheathed Copper Installation Cables

Professional Pvc Sheathed Copper Installation Cables

Professional Pvc Sheathed Copper Installation Cables

Professional Pvc Sheathed Copper Installation Cables

Professional Pvc Sheathed Copper Installation Cables

Professional Pvc Sheathed Copper Installation Cables

Professional Pvc Sheathed Copper Installation Cables

FAQ

·         Can we make an OEM order?

o    We can offer or supply goods as customers' requirements.

·         How can I get some samples? Free or not?

o    We can send some normal samples, absolutely free.

·         How does your factory do regarding quality control?

o    "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Ask you a question: how the computer CD-ROM power supply 5V and 12V two lines? Another audio and video cable which group?
Cable bridge at both ends to be installed across the ground wire, ground wire diameter can not be less than 16mm2. Wire ends and wire ends of the middle box to be installed at both ends of the ground wire, grounding wire diameter can not be less than 6mm2. Full length bridge with the grounding system connected to not less than 2. Cable bridge is divided into trough, tray and ladder-type, mesh and other structures, by the bracket, arm and installation accessories and other components. Can be set up independently, can also be attached to a variety of structures (structures) and corridor stent, reflecting the structure is simple, handsome in appearance, flexible configuration and easy maintenance features, all parts are required galvanized, installed in the building Outside the bridge, if it is in the vicinity of the sea or belong to the corrosion area, the material must have anti-corrosion, moisture resistance, good adhesion, high impact resistance of the physical characteristics. According to the relevant provisions of the specification, galvanized cable bridge for a good grounding. galvanized cable tray direct board each fixed bolt contact resistance should be less than 0.005Ω, then the cable bridge can be used as a ground trunk (dusting cable tray should not be used as a grounding line), the resistance of each cable bridge can be the following formula Calculate: r = ρ · L / S where: ρ = 15 × 10Ω-6 / cm (20 ℃); L = length calculated by 100mm; S = cross-sectional area of ​​cm2. The unit resistance value of the ladder on the pallet is shown in Table 2. The unit resistance value of the cable duct is shown in Table 3 The resistance of each ladder (or each cable slot) after the installation of the cable tray is the total: R = R (r + 1 / 3r ') where: R - ladder, that is, (cable trough) total length of the total resistance (mΩ); r - ladder unit length resistance (mΩ / m)
Q:PVC pipe on the GV.215-16 (C) What does it mean
TC line laying is the use of wire steel pipe laying. Wire steel pipe is a thin-walled tube, the nominal diameter is the outer diameter of the pipe. SC line laying is the use of ordinary welded steel pipe laying. Ordinary welded steel pipe is thick-walled tube, nominal diameter is tube diameter.
Q:Brief description of the difference between cable and cable.
Will not interfere with the middle there is no strong electricity! Cable no problem, may be the cable signal as before, you can use a waterproof tape wrapped up ah, do not exposed ah! If the wall with 220V power, then it is easy to string into the TV, the consequences ...
Q:Where the computer can be a bare chassis. Which hardware inside the framework
The general process is: program-controlled switches generated by the phone number will generally pass through a card board, and then board through the copper cable to the horizontal module, the horizontal module through the jumper connected to the straight line module; Copper connected to the general distribution frame, which also contains 110 patch panels! This 110 patch panel is very old. Now generally do not have a!
Q:What recycled rubber is suitable for the production of wire and cable?
Symmetrical receptacles need to be treated differently, with color distinctions most convenient.
Q:30 on the large number of cable how to fight on the 110 patch panel, how to order, please inform, thank you, which
According to the project to see how much current, according to the current selection cable thickness, and then choose to embed more rough casing, embedded casing is to cable alignment
Q:What is the warranty period for wire and cable?
General cable maintenance period is about 15 years, but to ensure that the normal use of the environment, such as the amount of temperature is below 70 degrees, but you are more than 70 working environment to use, of course, may not be used for a year. Therefore, the most important thing is to follow the instructions to use. Wire and cable recommended Ogilvy's.
Q:Wire and cable manufacturing process (to be detailed)?
Hello, copper wire per square safe current-carrying 6A, .05X6A = 3A.X220V = 660W, 3AX380V = 1140W, aluminum core for the same 4A algorithm,
Q:How to determine whether the square of the cable is standard
Horizontal laying of the cable within the cable, generally do not need fixed, natural laying can be. Vertical laying section of the cable within the bridge, with the need to match the line card, the use of tied rope (multi-purpose single insulated wire) one by one fixed cable, fixed spacing should meet the requirements. According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
Q:What is the power cable accessories used to do?
When using power, standby power, basically no radiation, can be considered negligible

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range