Professional Pvc Sheathed Copper Installation Cables
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 50000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: | Zhejiang, China (Mainland) | Brand Name: | cnbm | Model Number: | VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV |
Insulation Material: | PVC or XLPE | Type: | Low,Medium and High Voltage | Application: | s electric power distribution networks or industrial installations |
Conductor Material: | Copper or Aluminium | Jacket: | PVC or PE | Filler: | Non-hygroscopic Polypropylene(PP) |
Binder Tape: | Non-woven fabric | Metallic Armour 1: | Galvanized Stainless Steel Tape Armour(STA) | Metallic Armour 2: | Galvanized Stainless Steel Wire Armour(SWA) |
Metallic Armour 3: | Non-magnetic Steel Tape Armour(only for single core) | Metallic Armour 4: | Aluminium Wire |
Packaging & Delivery
Packaging Details: | wooden drum; iron-wooden drum or steel drum |
Delivery Detail: | Depending on the quantity |
Specifications
2015 new product electric power cable
1 Conductor:Copper or Aluminium
2 Insulation:PVC or XLPE
3 Voltage:Low/Medium/High Vol
2015 new product electric power cable
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers' requirements
FAQ
· Can we make an OEM order?
o We can offer or supply goods as customers' requirements.
· How can I get some samples? Free or not?
o We can send some normal samples, absolutely free.
· How does your factory do regarding quality control?
o "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.
- Q:If the question, please ask how the power cable should be set when the set of quotas (08 installation quota)? More
- TC line laying is the use of wire steel pipe laying. Wire steel pipe is a thin-walled tube, the nominal diameter is the outer diameter of the pipe. SC line laying is the use of ordinary welded steel pipe laying. Ordinary welded steel pipe is thick-walled tube, nominal diameter is tube diameter.
- Q:I am trying to run the power cable leading to the amplifier in my car but can not seem to find a hole or firewall to pass the wire through. My car is a 91 Toyota Tercel. Please and Thank you
- Make a new one. Use a drill bit the same size as the wire. They also sell firewall grommets that will prevent the wire from cutting.
- Q:I'm curious, because I was looking through the 'combo deals' for a part for a potential build, and one of them was a SATA cable (item itself was a hard drive). Does Newegg, or for that matter any major computer retailer, sell products that come with all the cables you need to actually use the part? I guess I'm primarily concerned with Hard Drives and Disk Drives in this case... oh, and PSUs I guess. And the mobo, will that have the power cable?
- Newegg Computer Parts
- Q:There is currently a power cable going into the back of my primary sata hard drive but i want to put another hard drive in but there is not another power cable
- I would try going to a nearby hardware store or electronics store that deals with computers and explain your situation to them. They can probably figure something out.
- Q:recently i purchased an imac G4, it included everything)keyboard,speakers,mouse ect.) but, it didnt come with a powercable. i knew this when i bought it, but thought it was a standard connector,i was wrong, it is a 3 pronged connector, I have a cable that will fit, but it is only 2 prongs, (it's missing the ground pin) . i only can return this item in 4 days if there is a problem with it, i could buy a powercord, but i risk it not coming in time. Can i use my 2-pronged power cord just to test it's funcionality. (fans,chime etc.) without the computer catching on fire of any other type of failure.Chris
- It's an ordinary 3-pin PC power cable. Any desktop, screen or printer should use one. If you don't have one, you should be able to easily find one for ?5.
- Q:How can you tell which lines on telephone poles are power lines, cable lines, and phone lines?
- I am not going to tell you that, because the only reasons I could think of why someone would ask this is for illegal activities, such as stealing the copper out of telephone wires. You are on your own on that.
- Q:when I Plug off power cable in my Laptop compaq v3424tu why its flucatuating the screen.Recently I am using windows XP.Pls reply if any suggestion.
- Maybe the power management resetting the notebook after unplug the power. it's not reset the whole system, only adjusting into battery mode (long life). Commonly, the screen will blank a moment. it's normal. the setting can be found in Control Panel, Power Option.
- Q:Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
- Power cable YJV22-8.7 / 15kv-3 * 300 Meaning: refers to the copper core XLPE insulated double steel tape armored PVC sheathed power cable, cable rated working voltage 8.7 / 15KV, cable for the three-core, single Conductor cross-sectional area of 300mm2. YJ: cross-linked polyethylene insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated working voltage 8.7 / 15 kV 3 * 300 Specifications: YJV22-8.7 / 15kv-3 * : Three conductors, single cross section of 300 square feet.
- Q:And can u please explain in detail how u get xbox live i dont want any free survey things just like do i have to buy a card how much it is do i need extra cables? ok thx!
- Sometimes the live cards go on sale at Target
- Q:While DISCONNECTED from the amp, I accidentally touched the power cable with the ground cable. Sparks went flying and I smelt a funny odor. Since then, when I go to turn on my radio, my amp only lights up for a second and then looses power. Unfortunately, I feel I've fried my ground wire (upon close inspection, the power/battery cables fuse is still good along with amp signal wire and RCA's) My question is simply this: When replacing my ground wire, can I use left over power/battery cable? I have about 3 feet left over from the install. Thank you for your help!!
- Theoretically, yes. I would make sure I was the only one using the system or messing around with it just to make sure no one mistakes it for a power cord. Also, wrapping each end with black electrical tape will work to identify it is a ground cable, being that black is universally known for ground. If you feel like wasting good money, wrap the whole cord with black electrical tape. Also, keep it away from professional installers so they do not mix it up, or just let them know it is a ground. Just keep it short enough so that it actually works as a ground (most manuals recommend less than 3 feet)
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Professional Pvc Sheathed Copper Installation Cables
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 50000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords