• Power Cable Rated voltage 1kV(1.2kV)and3kV(3.6kV) System 1
Power Cable Rated voltage 1kV(1.2kV)and3kV(3.6kV)

Power Cable Rated voltage 1kV(1.2kV)and3kV(3.6kV)

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Rated  voltage 1kV1.2kVand3kV(3.6kV)

PVC insulated Flame retardant and Fire  resistant cables

XLPE insulated Flame retardant and Fire  resistant cables

Brief  introduction

PVC insulated Flame retardant  and Fire resistant Power cables are fixed laid in the circuit with frequency  50Hz and voltage upto 3.6/6kV.

XLPE  insulated Flame retardant and Fire resistant Power cables are fixed laid in the  circuit with frequency 50Hz and voltage upto  3.6/6kV.

We can  produce Flame retardant and Fire resistant with PVC or XLPE insulated power  cables according to standard GB/T19666,Grade A, B,C or  D.

Rated  Voltage 0..6/6kV3.6/6kV

Conductor of cables can be  Copper and Aluminum.The cables can be single core,two cores,three cores,four  cores(including three main cores and neutral).five cores (including three main  cores and neutral and one earthing core,Four main cores and one  neutral).The cables can be with armour and  without armour.

We can produce cables with PVC  outer sheath,Flame retardant PVC outer sheath or with fire resistant  insulation.The cables are produced according to GB/T12706(eqvIEC60502) and  GB/T18380-2001(eqv IEC60332),or GB/T19216(IEC60311) and or the BS,DIN, or other  international standards. And we also design and produce cables according to the  requirement of our clients

Application

1、           Long term working  temperature for the cable with PVC insulated is 70

Long term working temperature for the cable with XLPE  insulated is 90

2、           Short circuit  temperature

For PVC insulated cable ,the highest  conductor temperature is not more than160℃.(lasting time not  over 5 seconds)。

 For XLPE insulated cable ,the highest conductor  temperature is not more than250℃.(lasting time not  over 5 seconds).

3、           Laying temperature not less than  0℃ and  the drop height is out of consideration。

4、           The cable with chemical stability,anti  acid,anti alkali, anti oil,anti organic solvent,not easy to be  burning

5、           Easy for installation,easy bending and  light

6、           Bending ratio


Item

Single  core

Three  cores

Non  armour

With  armour

Non  armour

With  armour

Min  bending ratius during installation

20D

15D

15D

12D

Near  joint box or cable terminal,bending with care and use  templet

15D

12D

12D

10D

NoteD is the diameter of  cable

 

Rated voltage  6kV(Um=7.2) and 35kV(Um=40.5)

XLPE  insulated power cable

Product  standard

XLPE  insulated cable has good electrical and pysical properties, resistant to aging,  resistant to the environment stress and chemical corrosion operation, with the  characteristics of simple structure, easy to use, no drop-height restricton when  laying,higher long-term working temerature (90℃).

Table of the voltage,cores  and cross-section


Item

Category      A B

3.6/6kV

6/10kV

8.7/15kV

12/20kV

18/30kV

21/35kV

Category      A B

6/6kV

8.7/10kV

12/15kV

18/20kV

-

26/35kV

Single  core

mm2

25-1200

25-1200

35-1200

50-1200

50-1200

50-1200

Three  core

mm2

25-400

25-400

35-400

50-400

50-400

50-400

 

The  cable with Category A rated voltage is used in the situation requiring not over  1 min.of grounding fault lasting time.For the cable with Category B rated  voltage, the grounding fault lasting time normally is not over 1 hour, max.  lasting time is not over 8 hours, annual ground fault lasting time altogether  should not be over 125 hours, Category C includes all the system expect Category  A and B.


Q:We need 25cm distance between Cat series cables.Can we wire Coxial Cable in the same conduit with a power wire?if yes than whats the reason for both Coxial and Cat Series Cables
No can do. You can run coax with your Cat 5e cable though.
Q:Alright, im most likely moving to Germany in December, and im bringing my PS3 over with me. That I bought here in the US.. Is it possible for me to buy the power cable for a PS3 that works in Germany and plug it into my current PS3, or will it short it out?
It won't short out, cause it will only take certain power
Q:What is the meaning of the cable 3 * 1 * 0.8?
The power industry mainly includes electricity industry and power plants and other power cables industry is the power industry to do the cable and cable should belong to the power industry but does not belong to the system within the power system only includes the State Grid China Southern Power Grid five nuclear power plants and other large state-owned enterprises
Q:Basically, I lost my power adapter to my monitor, and to be honest, I would like to try to avoid buying a new one entirely. I have an old HP laptop power cord that fits into my monitor, but the power specifications on it are different. The power rating on my monitor is 19V and 1.58A. I'm just assuming that's what it needs to run, and that you shouldn't go over that. My power supply from my old laptop converts standard AC into DC at 18.5V, which I'm assuming the difference in voltage between 19 and 18.5 won't really affect anything, but the amperage on my power supply is close to twice as high, at 3.5A output. That's where my concern is, if I where to plug this into my monitor would anything bad potentially come out of it? Don't comment saying quot;Oh, just buy a new one.quot;, I've stated I want to try and avoid that. Thanks in advance.
It might work,give a try.
Q:what do ferrite beads do on power and audio/speaker cables do and is is it worth buying some and fitting them to reduce interference?or are they just as pointless as monster hdmi cables?thanks!.
Couldn't find a quantitative discussion of how effective they are, but according to this wikipedia article they are needed for a device to obtain FCC class B certification.
Q:Hello,if you want to split your power distribution cable,how do you do so ?? I want the cable to be divided into two other smaller cables,do I use a T-joint or what ???Thx!!!
What sort of power cable? If it is mains or an automotive power outlet, you can get splitters for those.
Q:My stereo in my car is cutting out (powering off and on again) on high volumes. I'm trying to determine if it's my amp/sub-woofer or not. I switch off my amp with my remote power switch (the blue cable switch) and I still get the cut out. Is this conclusive enough to indicate that the problem is not with my amp/subwoofer?
valuable it extremely is put in on your motorized vehicle in spite of the undeniable fact that it's not extremely valuable. The gadget bypasses the main significant and ignition exchange giving capacity to the motorized vehicle and starter. issue is that your motorized vehicle will initiate however if its in kit. think of of approximately status indoors your place and and wanting to warmth up your motorized vehicle. You grab your keys and hit the button. next subject you recognize is that your motorized vehicle has basically ran off by using itself and crashed into each element in its course as a results of certainty it became into in kit. Your coverage employer won't even pay for the wear and tear and tear as a results of certainty the education on the distant initiate says to no longer set up on education manual transmission autos. So valuable you could yet no you shouldn't
Q:A network cable must cross a power cable. What can be done to minimize the amount of EMI?
Metal shielding would be best. This could be as simple as wrapping each cable with aluminum foil near the cross-over point. Hope this helps.
Q:Hey and just to start off with, your answer will be deeply appreciated, thanks..... Its about my PS3, when I was flying to Lebanon (which I am in now) my PS3 power cable got taken and thrown away by the airport officials the second time my bag was scanned.....so now I can't play any games because of this, it sucks goat balls, I know but my question is.... Where can I find another power cable..... P.S, my console was bought in Canada so the voltage was 120v I think but it was misbehaving when I used it with the converter I bought so I tried using without it and it worked like a charm on 240v, if that helps.... if there are any details I have missed out, my e-mail address is .uk
that sucks!!! and weird, when i was boarding a plane, they kept all my stuff, but they did check it.... the best thing you should do, is buy a new one from online and let it go to your destination.
Q:Our comcast HD cable box usually has the time and a little red light on front. Its blank and has no power. It is plugged into a power strip that also has the TV and stereo, yet those are working fine. We reset the power strip and still no power to the cable box.Any ideas? Please no rude remarks. Thanks.
Check your cable bill. You are most likely renting the cable box. If so then take it back to Comcast. They will exchange it for a working one. One of mine did that not too long ago, and I had no hassles exchanging it.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords