Power Cable,C7 Female To Nema1-15 Male

Ref Price:
Loading Port:
China Main Port
Payment Terms:
L/C,T/T
Min Order Qty:
300 Pieces pc
Supply Capability:
1,500,000 Piece/Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Power cable

US SVT Europe VDE certified power cord

power cord cables cord sets C7 Female to  NEMA1-15 male

 

Feature:
1. Rate temperature:90C;

2. Rate voltage: 450/750v;

3. Standard: Din VDE2829;

4. Tinned or bare copper conductor;

5. LSZH insulation, ROHS compliant, uniform insulation thickness to ensure stripping and cutting;

 

Description:

It is populor in Japan, China and America.

 

power cable series:

EUROPE CEE 7 TO C13 FEMALE

 

C13 FEMALE TO NEMA5-15

 

C13 FEMALE TO C14 MALE

 

NEMA5-15 MALE TO FEMALE

 

NORTH AMARICA NEMA1-15 TO C13 FEMALE

 

EUROPE CEE7MALE TO C7 FEMALE

 

AUSTRALIA ETSAS/86 MALE TO C7 FEMALE

 

AUSTRALIA ETSAS/86 MALE TO C13 FEMALE*2

 

UK MALE TO C13 FEMALE

 

C14 MALE TO AUSTRALIA ETSA S/86 FEMALE

 

C7FEMALE TO NEMA1-15 MALE

 

ITALY MALE TO C13 FEMALE

 

We are one of the biggest groups in China in all kinds if power cords, cables, adaptors and so on. We always provide our best price and the best quality products. Please contact us for details by our contact information listed in our website printed in our products picture.

 

Why we choose Okorder.com?

Okorder.com is a professional and reliable online E-market place

Providing a variety of products with reasonable prices

High quality goods provided by factory suppliers

Shipping to over 200 countries.

One-stop sourcing

Dubai Logistic Complex

 

Okorder Quality Control?

We hold a very strict quality control system to check every connector of our products for your safety.

 

Okorder services for you

1.7*24 hours Hotline & Email Service

2. Your inquiry related to our products or prices will be replied in 24hrs.

3. Well-trained and experienced staffs to answer all your enquires in fluent English

4. OEM&ODM, any your customized demand we can help you to design and put into product.

5. Distributor ship are offered for your unique design and some our current models

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to connect the power cable pre-branch connector
In the pre-measured size cut out the jacket and insulation, according to the different cross-sectional size of the cable cut the size of the jacket and insulation different; with C-shaped tube corresponding to the corresponding color sequence crushing the trunk and branch lines, crimping attention to crimping The strength of the clamp, can not be too loose or too tight, too loose will cause the cable crimping off, resulting in open circuit, crimping too tight will break the conductor or cause the conductor stranded in the contact with a good conductor with polytetrafluoroethylene With the winding baking transparent, and then wrapped waterproof tape (tiger belt) can be used after the wooden hammer shrink the cable core to facilitate injection molding in the injection process should choose the appropriate mold and injection molding machine injection mold injection, the mold is too large cost Waste, the mold is too small caused by defective, bad seal at both ends of the running coke, affecting the injection effect
Q:Calculate the control cable under what circumstances the cable terminal needs to be calculated
" Why should the closed wall or protective wall closed on the second side of the closed junction box? This need to understand if you do not add this closed junction box, what kind of harm Civil air defense project in the closed wall is divided into the clean area and the area of ​​the infected area, and the wire tube in the thread after the inside is a cavity, directly through the wall to communicate with the cleaning area and exposed areas, so wartime works outside the dyeing The poisonous air can penetrate into the clean area through the cavity inside the wire tube, which is harmful to the personnel inside the project And the installation of a sealed junction box, you can thread in the line after the box filled with sealing material to block the tube cavity connectivity This is why the electrical safety pipe in the air defense project must pass the closed wall or protect the closed wall when the two sides must be closed in the closed junction box reasons
Q:Whether high voltage cables can be built in belt corridors
First of all, it should be noted that the short circuit is caused by the current is too large, short circuit occurs when the short-circuit current will be very large, can not be used to describe how many times, and electrical design to consider the wire cross-sectional area will not be great, Heat, so the conductor will be hot
Q:Will the two 16 square copper wire with what specifications of the trunking
If the network cable is shielded with the network no problem, in fact, the main problem is not interference, it touches on security issues, from the truth, the strong and weak electricity can not take a bridge, if you must go inside a bridge, to add metal partitions The
Q:110 voice patch panel directly to the telephone line can be connected to it
YJ refers to the insulation material for the cross-linked polyethylene, V refers to the inner layer of PVC within the steel sheath armored copper power cable as aluminum core was YJLV22
Q:PVC pipe on the GV.215-16 (C) What does it mean
SC pipe welding fluid with welded steel pipe, the general thread connection, or casing welding connection. TC pipe is a thin-walled steel pipe, referred to as wire tube, you can thread connection, tight connection, buckle type connection, not casing welding connection.
Q:Power cable 5-color line, respectively, what color, what role?
YJ: XLPE insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated voltage: 8.7 / 15 kV (phase voltage 8.7 = 15 / 1.. line voltage 15kV) 3 * 300: Three conductor cross-section of 300 square copper conductor Another: If YJLV is the aluminum core. Here is not marked what the material is conductor, you can default to copper conductor.
Q:The UV lamp is fitted with ozone and no ozone difference
Man, your weak tube is not quite long? If the length of the pipeline is very long, you need to wear the wire, unless you have no wire can be threading method. Your length of the pipeline is very long, in the tube when the tube has been added? There is no wire box to make up.
Q:Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
Strictly speaking is not in line with the norms. Special signal lines may be subject to interference
Q:Wire inside the two lines, red and black, black line is the line of fire or zero line ah?
. 1.8.7 / 10kV U value of 10KV, which can withstand the maximum voltage of 12KV8.7 / 15kV U value of 15KV, which can withstand the maximum voltage of 17.5KV2.8.7 / 10kV is 10KV system in the first Class II cable (fault time can be greater than 1 minute) 8.7 / 15kV is the first type of cable in the 15KV system (failure time is not more than 1 minute) 3.U0 / UU0 - conductor and insulation shield between the voltage U - the The voltage between the conductors is two, the cable is usually a few or several groups of wires [at least two] stranded from the rope similar to the cable, each group of wires insulated from each other, and often around a central twist The entire outer package has a highly insulated cover. Multiple in the air or in the ground, underwater, for telecommunications or power transmission.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range