• Plastics insnlated and sheathed control cable System 1
Plastics insnlated and sheathed control cable

Plastics insnlated and sheathed control cable

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

As connecting wires of all kinds of electrical instruments and automatic devices to control, monitor and protect circuits of AC.

Specification :

1.Better quality & Faithful business

2.Prompt delivery & reasonable price

Plastic Insulated control Cables are used for rated voltage up to and including 450/750V

The long-term operating temperature of PVC insulation cable conductor should be lower than 70°C,and that of XLPE insulation should be lower than 90°C

The installing ambient temperature of cables shouldn’t be lower than 0°C,the Min. bending radius of installing is 6 times of the outer diameter

Unarmored control cables

Such unarmored control cables are suitable for laying indoors and in the electrical cabinets, however, the cables can’t bear larger external mechanical forces.

PVC sheath has stable property and excellent chemical corrosion protection characteristics, also with the features of non-fire propagation and non-water absorption, which greatly ensure the cables’ service life.


Control cables with steel wires armored

Steel wires armored control cables can endure certain mechanical tension, which are widely suitable for high-level difference environment, also can be installed vertically

Cables with screen have good shielding and anti-interference performances.
Control cables with screen

Generally speaking, there are two ways of copper wires braided screen and copper tape wrapped screen for control cables, however, copper wires braided screen has stable structure, the effect of screen won’t change with the cable bending or appearance factors etc, but also doesn’t have influence on cables’ flexibility, braiding density can reach over 80%, besides,copper tape wrapped screen percentage of coverage can reach up to 100%.


The specific models see the  Annex 2

Annex 2: LSZH-XLPE/ Irradiated Cross-linked Insulated Control Cables

WDZ-KYJY

WDZ-KYJ(F)Y

Copper conductor, XLPE/radiated crosslinked insulation and Polyolefin sheath flame retardant control cable with LSZH

For laying in doors and in ducts, the cable has property of flame-retardant with high requirements of safety and environment-friendly cables.

WDZ-KYJYP

WDZ-KYJY(F)P

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and copper wires braided shielded control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, as well as the good shielding and anti-interference property.

WDZ-KYJYP2 WDZ-KYJY(F)P2

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and copper tape wrapped shielded control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, as well as the good shielding and anti-interference property.

WDZ-KYJY23

WDZ-KYJ(F)Y23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant and steel tape armored control cable with LSZH

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

WDZ-KYJYP23

WDZ-KYJ(F)YP23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant LSZH control cable with copper wires braided screen and steel tape armored

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

WDZ-KYJYP 2-23

WDZ-KYJ(F)YP 2-23

Copper conductor, XLPE/radiated crosslinked insulation, Polyolefin sheath flame retardant LSZH control cable with copper tape wrapped screen and steel tape armored

For laying in doors and in ducts, has property of flame-retardant with high requirements of safety and environment-friendly cables, which also can withstand certain external mechanical force.

Q:I live in Chicago, and I want to know if somebody can help me. The next house on mine have electrical power cable, telefon and cable from my back yard and pas my propriety aprox 60 tf, the last two stay on my garage, its legal ?Know haw i can do to move the cable? some codes or regulation, samething? Thanks, Best regards.
I do not know the codes or regulations in Chicago but i do know in most states it against the law to have power lines resting on a structure. Those two lines resting on the garage could be the cable and phone company's and that is not against the law. However you could call the phone company and cable company and ask them to move them for you. If you can make a valid point that those lines are causing you harm or disturbing you in anyway possible then the company's will have to move it. And for the power cables there is probably nothing you can do unless it is really resting on your garage. But they will just tighten the line and not actually move it.
Q:I've got everything connected to my motherboard, but cant start up my computer until i get these small cables connected to my motherboard. I just want to start up my computer. I've got the cpu in, the cpu fan, ram, speaker,hard drive, floppy etc.. How do i fit the cables in the question above, in the right order so my computer will start. I believe they go into the USB and PANEL on my motherboard.thank you
Not enough info. But from what you wrote, the only one you need to connect to get the mainboard started is the Power SW. All others are indicator or I/O. The Power Switch cable is not polarized but the LEDs are. LEDs need the +/- in the right direction. Be very careful on the USB connections or you could burn up a USB device. They are critical. You should have a manual if the mainboard is new. If it's used, look around on the surface of the board for a manufacture and model number. Then type it into google and see if you can find an on-line manual.
Q:what do ferrite beads do on power and audio/speaker cables do and is is it worth buying some and fitting them to reduce interference?or are they just as pointless as monster hdmi cables?thanks!.
Generally they are fitted to fix a narrow bandwidth issue, so you would need to know what interference issue you are trying to fix. In most coaxial application this is for the roll off between shielding types.
Q:I need the cables/cords for the Xbox 360...all the cables/cords
Power Cable AV Cable or HDMI Ethernet (if you don't have the slim and want to use the Internet)
Q:I bought a used DVD player that didn't come with a power cord or power cable.On the back of the DVD player, the power cable input looks like this:__________|_o__|__o__)So basically it looks like the power cable should have two wires with one side being flat and the other end being a half circle.What is the technical name for this power cord so I can easily find it if I go to Radio Shack?Thanks.
Ask for a 6 ft AC power cord. They come in a few difference shapes so just describe what you did here. If it helps reference Radio Shack model/catalog number #61-2878. Good luck!
Q:I asked before about installation of power and control cable in the same conduit .. I think it is not a good practice.. I want to ask about installing 2 power cable each 480V in the same conduit ..Also I want to know if it is mentioned in any standard like NECthx
You can as long as every cable in the raceway is insulated at least for the maximum voltage in the raceway. NEC 300.3 (C) (1). You also need to consider raceway fill limits, and ampacity derating for 4 or more current carrying conductors.
Q:What fuse should I use to run my power cable to the amp?
Measure the current (A) drawn in operation, increase by 50% and round up to the nearest standard ampacity: If the drawn current in normal operating conditions is 10A @ 12Vdc, 10*1.5 = 15A, which is one of the standard fuse ampacities (no need to round up).
Q:UPGRADING BIG 3. ARE THOSE TWO CABLES THE SAME THING ? DOES IT MATTER WHICH ONE I USE FOR THE BIG 3 UPGRADE?
The wire is the same, just different color so you dont confuse yourself when installing. You'll actually have to upgrade BOTH wires to properly do the big 3. 1. + Batt to + Alternator output post 2. - Batt to frame/chassis 3. frame/chassis to engine block 4. (For extra) engine block to - Batt All in at least 0 awg gauge wire. I've done my in 0/2 awg gauge welding cables.
Q:Does the Corsair CX series CX500W PSU come with an AC power cable?
I all my years, I've yet to see a power supply that doesn't come with a new power cable. Thing is, tho, the power cable is standard in 99.9% of power supplies. One will pretty much work on another.
Q:Can anyone tell me the best place to run the power cable for my amp from the battery through the firewall? (2000 Chevy Impala)
Look for where the factory wire harness goes through. there's usually enough room to cut or drill a whole and pass your power wire through. If not, you'll have to make your own hole in a safe place.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords