Pine Scaffolding Plank with steel cap of both ends for construction

Ref Price:
Loading Port:
Lianyungang
Payment Terms:
TT OR LC
Min Order Qty:
50 m³
Supply Capability:
3000 m³/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

LVL Scaffolding Plank

 Laminated Veneer Lumber Scaffolding Board for construction

Features:

1) Dimensions: length: 1980/2980/2500/3900/3980/5980( length within 12 metres)

width: 220/225/230mm

thickness: 38/39/42mm

we may manufacture kinds of sizes according to clients' requirements.

2) Material: Radiate Pine from New Zealand

3) Adhesive: WBP glue ( Environment Friendly )

4) Produce Ability: 60,000CBM/Year

5) Standard:

We are applying an inspection certification from third party agency, now we are instructed under its China agent.

6) SGS Test Report by according AS 1577-1993

7) Usage:

LVL is used primarily as structural framing for residential and commercial construction and is well suited to applications where open web steel joists and light steel beams might be considered. Others uses include scaffold planking and as flange members for some proprietary prefabricated wood I-Joists. LVL can easily be cut to length at the jobsite.

Application: For use as scaffold platforms or decks in accordance with U.S. Department of Labor Regulations (OSHA) or British Standards

Material: Structural laminated veneer lumber (LVL)

Standards: AS/NZS 4357:1995 Structural laminated veneer lumber GB/T 20241- 2006 Standard for laminated veneer lumber ANSI A10.8 – 2001, Safety Requirements for Scaffolding OSHA, Occupational Safety & Health Administration, U.S. Dept. of Labor, Regulations (Standards – 29 CFR) Scaffold Specifications – 1926 Subpart L, Appendix A BS 2482 Specification for Timber Scaffold Boards

Species Used: Plantation forest Radiata Pine

Adhesive & Bond: Phenolic, Type A (WPBP) Bond

Section Size: 38、39、42mm thick x 220、225、230mm wide (Tolerances, -0, +2mm)

Moisture Content: 6% to 18%

Lengths: To customer specification up to 12000mm (Tolerance, -0mm, +10mm)

Approximate Mass: 580kgs/M3

Strength & Stiffness 1) Batch sampling of LVL from production and testing for Verification: Modulus of Elasticity and Modulus of Rupture 2) Boards proof loaded and rigidity measured for verification of strength claims

Edge Branding: OSHA, BS2482, PROOF TESTED SCAFFOLD BOARD, MM/YY

Finish: Unsanded faces, sawn edges, arrisses chamfered (to prevent splintering), ends painted (to inhibit moisture egress/ingress)




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Judging wood is the standard for plywood
For example, an old dresser may seem dilapidated, but maybe it is still hard to find now good wood to do it. In this article, we will explain to you how to identify a piece of furniture, and to ...
Q:The Decorative veneer veneer plywood grade classification
To remind manufacturers and other forms of consumer do not meet the requirements of China's decorative veneer veneer plywood standards
Q:What is medium density fiberboard
Plywood can be structured, gluing performance, surface processing, treatment methods, shape, use to classify, commonly used is an ordinary plywood
Q:What is the density of plywood?
The number of layers is generally odd, and few are even. Vertical and horizontal direction of the physical and mechanical properties of small differences. Commonly used plywood type plywood, penta and so on
Q:Defects are divided into four grades
Sanding plywood refers to the plywood of the sanding machine (or scraper) sanding (or scraper).
Q:What kind of glue is today's plywood?
if you want the wood products have a stronger waterproof and moisture-proof performance, you can use E1 (or even E0) melamine glue.
Q:What harm does the plywood factory work?
Occupational acute benzene poisoning is the workers in the professional activities, short-term inhalation of high-dose benzene vapor caused by the central nervous system suppression as the main manifestation of systemic diseases
Q:Plywood quality requirements include appearance level, size, physical and mechanical properties of the three elements.
Thickness from 4mm below the thin plywood. 3mm, 3.5mm, 4mm thick plywood for common specifications
Q:Class III resistant tide plywood class IV tonic resistant plywood
and the dashboard and the inner panel are arranged symmetrically on both sides of the center layer or the core.
Q:What is the amount of construction works used for this plywood?
Three types of plywood for moisture-resistant plywood, can be immersed in cold water for a short time, suitable for indoor use at room temperature. For furniture and general construction purposes;

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range