Product Description:

Product properties:  

Uses: This product is applicable to shared antenna systems, closed circuit television system and other signal transmission, and such cable has the characteristics of small attenuation and strong anti-interference


Structure and size of YWV (Y) PE physical foaming insulated coaxial RF cable products


Items

Sizes

SYWV(Y)-75-5

SYWV(Y)-75-7

SYWV(Y)-75-9

SYWV(Y)-75-12

Inner conductor diameter

1.00±0.02

1.66±0.02

2.15±0.03

2.77±0.03

Outer diameter of foaming medium (insulator)

4.80±0.20

7.25±0.20

9.00±0.25

11.50±0.30

Outer conductor

Aluminum-plastic composite belt or aluminum foil + tinned soft copper wire braiding, and the nominal diameter when the tinned copper wire is used in braid

0.12~0.15

0.12~0.15

0.12~0.18

0.12~0.20

The maximum diameter braided angle of outer conductor ≤ 45 °, filling factor of 0.23 (minimum)

5.8

8.3

10.1

12.6

Jacket

Thickness

0.70

0.85

0.96

1.00

Outer diameter

7.2±0.30

10.3±0.30

12.2±0.40

15.40±0.40

Delivery length

Length of each volume

100

100

200

200

Short break

20

50

50

50

As for length of each conducting wire of -7, -9, -12, the order requirements shall prevail

 

Electrical performance of SYWV (Y) polyethylene physical foaming insulated coaxial RF cable products

Items

Sizes

SYWV(Y)-75-5

SYWV(Y)-75-7

SYWV(Y)-75-9

SYWV(Y)-75-12

Core cable dielectric strength

1.6

1.6

1.6

1.6

Insulation Resistance 500V DC >

10000

10000

10000

10000

Sheath dielectric strength

Spark test

3.0

5.0

8.0

8.0

Water immersion test

2.0

3.0

5.0

5.0

Characteristic impedance 200MHZ

75±3.0

75±2.5

75±2.5

7.5±2.0

Voltage decrease constant

50MHz

4.9

3.1

2.6

2.0

200MHz

9.9

6.5

5.2

4.1

550MHz

16.8

10.7

8.5

6.7

800MHz

21.0

13.9

11.5

92

Return loss

VHF

20

20

20

23

VHF

18

18

18

20

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How come my computer turns on just by inserting the power cable in the PSU ?
I accept as true with the skill furnish suggestion. once you're taking it out as pronounced by previous answerers, take it with you once you bypass get the hot one, with the intention to make certain you get the proper variety of skill furnish. regardless of what the terrific effect is or what the restoration finally ends up being, i can't rigidity sufficient the cost of having an Uninterruptable skill furnish (UPS) which between different issues, materials sufficient time to suitable close down your laptop in a blackout. IMHO, Belkin and APC are the terrific 2 on the industry.
Q:What's the function of data cable and power cable?
One is to transmit data and the other to transmit power. Your head not working this morning or just trolling?
Q:Where can I find a 8-pin male to 8-pin male power cable?
Most people use a molex to 8 pin adapter. Link below.
Q:where can i purchase a power cable for my compaq laptop?
try okorder.com and their cables to go
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:Power cable to my stereo in my 2005 Dodge Neon broken?
the cables are not a life and run away from the dash , that never happends, and if the cable is there its not broken the power comes from the ignition switch not the battery , so you have a bad fuse or bad ignition switch most likely it is only a fuse, did you know there are 2 boxes ? check both
Q:Can I make my own power cable for speakers?
Since you give such scant information the only answer I can give you is maybe. The biggest drawback I can see is the voltage/power issue. USB specs say that you can draw 500 milliamps at 5 volts so if your speakers run at 5 volts and don't draw more than 500 mA then yes you can. If your speakers use a different voltage or have higher current requirements then no. (what is up with the 12V DC 0.5A wall adapter? You don't identify what that is ... is that what you use to power the speakers? If so, then you can't power the speakers with USB.)
Q:Power cable to Netgear router won't fit?
If it is the correct adapter for the router and it fitted before, gently force it and it will comfortably fit eventually. There is probably a reason it doesn't fit now (it has been pulled out with some force) so I would suggest getting a new power adapter for it if the above does not work
Q:harddrive power cable stuck.... HELP PLZ?
Thats nothing new..Molex connectors often stick do not try to pull it out by the wires! grab it by the sides of the connector and wiggle it back and forth (side to side) it will come out eventually!
Q:A power supply cable is brakes during heavy storm and falls on the ground. Bear approach gets shocked becauase
a. when the wire touches the ground, it sets up an electric field that gets smaller as it gets further away from the wire. If the voltage is high enough, then the difference between the bear's front and hind legs might be enough to shock the bear. If you are ever in a situation where you are near a downed power line and you MUST get away, you should try hopping away on one foot, or at least keep both feet as close together as you can.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range