Patch Panel 48 port

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Piece/Pieces pc
Supply Capability:
10000 Piece/Pieces/week pc/month
  • OKorder Service Pledge
  • Quality Product
  • Order Online Tracking
  • Timely Delivery
  • OKorder Financial Service
  • Credit Rating
  • Credit Services
  • Credit Purchasing

Add to My Favorites

Follow us:

Specifications of Patch Panel 48 port

patch panel cat6A/cat6/cat5e/cat3 utp/ftp 24 port/48 port

110/Krone/Dual cat3 cat5e cat6 cat6a patch panel

Meet TIA/EIA-568-A

  patch panel cat6A/cat6/cat5e/cat3 utp/ftp  24 port/48 port / 25 port/50 port

  110/Krone/Dual cat3 cat5e cat6 cat6a patch panel

Meet TIA/EIA-568-A and TIA/EIA-568-B Category 6 requirements.

Meet TIA/EIA TSB-40

Meet ISO/IEC Generic Cabling Standard 11801

Meet CENELEC Generic Cabling Standard EN50173

Angle: 90 Degree

Termination: 110, KRONE,DUALTypes (3 types)

Electrical of Patch Panel 48 port

According to UL 1863

Current rating: 1.5 Amp Max.

Voltage rating: 150 Volts

Contact resistance: 20 m-ohm

Insulation Resistance: 500M-ohm

Dielectric Withstand Voltage: 1000 V AC RMS, 60Hz 1min

Materials of Patch Panel 48 port

Housing: PC UL94V-0

IDC: PC UL94V-0, Accept 22-26 AWG Solid Wire.

PCB: FR4 1.6mm(0.04") thickness, 2 layers

Contact: PC Ul94V-0, 0.45mm(0.018") Diameter Phosphor bronze with 3 u" to 50 u" Gold plating

 Patch Panel 48 port

 Patch Panel 48 port

Q:What machinery is required to make wire and cable?
Oh, the pipeline is poured before the layout according to the design drawings.
Q:What is the difference between wires and cables?
The introduction of the device in the form of: sealing ring (sealing ring is to achieve the required protection level of the shell and the use of cash-saving brush to help find the silent material or elastic material parts) type of introduction device; casting solidified packing seal Type introduction device; metal seal ring introduction device
Q:What brand of cable is good, what are the top ten brands of wires?
Power circuit box, the home of the circuit is divided into lighting, walls, air conditioning, etc., there is the bathroom and the kitchen line and the separation of the room.
Q:Wire and cable model ZD what does it mean
The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort
Q:Decoration when the purchase of water pipes, wires and other items included in the account
KVV is the control cable, generally do industrial control; and RVS is twisted pair, generally used for weak system, to eliminate the interference requirements of the occasion, such as two-wire bus system, specifically, the electrical fire bus more Such as RS485 bus and so on.
Q:The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
Power lines tied together, usb line bundled together, high and low pressure apart. Tie the tie on the line
Q:What is the difference between the WDZ wire and cable, the ZR wire cable and the NH wire and cable, and what kind of wire and cable should be used?
Make a mark, such as red set into the bottom for a color in a layer, or you can draw a few plans, water and electricity is a strong power is a weak and one, the label can do a good job
Q:What is the warranty period for wire and cable?
Wire and cable warranty period is 30 years of national warranty period. But the specific warranty period according to the type of wire and cable and the use of conditions and temperature and applicable methods to determine. General cable maintenance period is about 15 years, but to ensure that the normal use of the environment, such as the amount of temperature is below 70 degrees, but you are more than 70 working environment to use, of course, may not be used for a year. Therefore, the most important thing is to follow the instructions to use.
Q:Apple 6 Charging Why always show this cable has not yet been certified
And I answered the other person's question is very similar: . the line of the banding distance of not more than 1.2 meters, the two ends of the wire box outlet tube 15CM should be ligation; . casing embedded, then through the basement wall, the surface must be installed rigid Waterproof casing, that is, steel pipe + water ring; through the fire pool, living pool: flexible waterproof casing; (wing ring specific practices can be collected online related Atlas); through the floor, according to whether the design requirements , Under normal circumstances PVC casing on it. Note: . rigid waterproof casing, flexible waterproof casing is a one-time reserved in place, through the floor of the casing of the flower lamb to suppress the barge of Xi Jie Xi Xi shou, is the first stay hole, when the installation of riser Casing, because the floor casing has every layer, the location of the reservation will always be biased, in order to ensure vertical vertical pipe, and finally unified hanging line repair hole and then install the riser and casing. . now most of the bathroom are dirty, waste and diversion, and more of the riser, and so on, the air conditioning casing of all the shear wall should be embedded, to avoid the subsequent damage to the structure of drilling (no stay can only drill) Note that the location of the hole and the installation of the riser will affect the opening of the toilet window. . the casing is the casing, riser is the riser, casing than the riser model 1 to 2 level. . plate at the end of flat, board 2 to 5CM higher to see if you need to do leveling layer.
Q:Apple 6splus charge may not support this accessories how to do more
When the lighting circuit and the power circuit shared ladder, BV line is not allowed to put in the ladder, so it is recommended to use the wiring of the lamp ZC-YJV-3 * 2
Founded in 2009,we are the professional manufacturer of computer room management and power distribution Cabinet perimeter devices. We have two divisions. The first is a PDU division, it's main products are PDU, KVM servers, and the cabinet temperature controller. The second is Chassis division, it's main products are industrial computer chassis, server chassis, chassis data storage, agent industrial power supplies, industry guides. To meet IT, and Cabinet industry customer needs.

1. Manufacturer Overview

Location Guangzhou,China
Year Established 2009
Annual Output Value Above US$10 Million
Main Markets Mid East;Western Europe;North America
Company Certifications ISO 9001:2008;

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen
Export Percentage 90%
No.of Employees in Trade Department 50 People
Language Spoken: English;Chinese;
b)Factory Information  
Factory Size: Above 300,000 square meters
No. of Production Lines Above 8
Contract Manufacturing OEM Service Offered;Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request