P-2 inch self priming Centrifugal Non-clogging sewage pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 120 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Welcome to lanco pump
P-2 inch self priming Centrifugal Non-clogging sewage pump
is our latest generation product base on US technology and craftwork. It is designed
for economical & trouble-free operation in handling solid-laden liquids and slurries.
Model P-2
1.Net weight 92kg |
2.Shipping weights 114kg |
3.Impeller dia. 158.75mm |
4.R.P.M. from 1150rpm to 2900 rpm |
5. Max solids 44.45mm |
Self-Priming
1. 650RPM 1.5m-750RPM 2.4m
2. 850RPM 4.9m-950RPM 5.8m
3. 1050RPM 6.7m-1150RPM 7.3m
4. 1250RPM 7.6m-1350RPM 7.6m
5. 1450RPM 7.6m-1550RPM 7.6m
6. 1650RPM 7.6m-1750RPM 7.6m
7. 1850RPM 7.6m-1950RPM 7.6m
Main charactor
1. beautiful shape and fine structure, reliable performance;
2. with strong capacity of self-priming, no need to equip with flap valve;
3. non-clog, and with powerful capacity of passing big solid;
4. The unique lubrication oil mechanical seal cavity makes the performance more reliable.
5. The hole can make sure that stronger sewage can be cleaned quickly when pump is jammed.
6. Special check valve structure can make the pump start quickly next time.
7. When operated, the pump can self-priming with gas and liquid at the same time.
8. Low rotary speed, reliable operation, long useful life, easily maintenance.
9. Advanced pressure protector make pump operate safety.
10. Very competitive price, high quality, small MOQ, fast delivery,OEM required,exporting plywood case.
Features
Solids Handling Impeller
Exclusive Abrasion-Resistant Seal
Removable Cover Plate with Easy-Grip Handle
Replaceable Wear plate
Removable Rotating Assembly
Application
1. Municipal Project, Sewage Project, Instruction Project;
2. Transportation of the sewage of uptown;
3. Sewage transportation in Hospital, hotel,slaughter house,fish breeding;
4. Classification of municipal sewage treatment factory and concentrate treatment systems engineering;
5. Transportation of the factory and contaminated water;
6. Sewage and deposit of water purifying system;
7. Industrial sewage of light industry,paper mill,textile,food processing plant,chemical industry,electric utility,deep mines,etc.;
8. Wine and sugar industry;
Operation condition
1. The temperature of medium no more than 80°C,the density of medium is 1.0~1.3*103Kg/m3,PH is within5~9.
2. Max diameter of solid should be less than76.2mm.
3. Max suction lifts no more than 3 inches or 7m.
4. Volume ratio of solids in the medium ≤2%.
5. Max.working pressure and suction head please refer to performance curve and table.
Performance
MODEL | R.P.M. R/MIN | FLOW m3/H | TOTAL HEAD m | MOTOR HP | NET WEIGHT kg | GROSS WEIGHT kg | MAX SOLIDS mm |
P-2 | 1150-2900 | 46 | 36 | 1 – 10 HP | 92 | 114 | 44.45 |
P-3 | 650-2150 | 107 | 35 | 1 – 20 HP | 183 | 205 | 63.5 |
P-4 | 650-1950 | 163 | 36 | 1 – 30 HP | 259.5 | 280 | 76.2 |
P-6 | 650-1550 | 330 | 33 | 2 – 40 HP | 364 | 391 | 76.2 |
P-8 | 650-1350 | 600 | 34 | 7.5 – 75 HP | 581 | 634 | 76.2 |
P-10 | 650-1450 | 775 | 40 | 10 – 100 HP | 635 | 663 | 76.2 |
P-12 | 650-1250 | 1275 | 42 | 20 – 125 HP | 998 | 1066 | 76.2 |
H-3 | 850-2150 | 85 | 62 | 1.5 – 25 HP | 214 | 225 | 20.63 |
H-4 | 850-2150 | 148 | 58 | 3 – 40 HP | 272 | 297 | 28.57 |
H-6 | 850-1950 | 308 | 57 | 5 – 75 HP | 413 | 437 | 31.75 |
- Q:Excuse me, what is the water pump from the lotus root?
- Submersible sewage pump with septic tank, outlet pipe automatic coupling installation, dipping down can be.
- Q:Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
- The spoon pipe is not a feed pump, but also is an adjusting oil inlet device of a hydraulic coupler matched with a feed pump
- Q:Rules for operation of centrifugal pumps
- Operating rules:1, before starting to check whether the water pump foot loose, coupling shield, and motor fan blade cover is intact, in order to ensure the safety of equipment and personal safety.2. Check whether the inlet valve is open and open as fully as possible. Is the outlet valve closed, open the bleeder valve, exhaust until there is no air, and close the bleeder valve. At the end of the valve to the pipeline in the pump cavity filled with water.
- Q:Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
- 3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
- Q:What flowmeter is installed after the pneumatic diaphragm pump?
- Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
- Q:Difference between pump and compressor
- A pump is a machine that transports liquids or pumps liquids. It transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. The pump is mainly used to transport water, oil, acid and alkali liquid, emulsion, suspension emulsion and liquid metal, and also can transport liquid, gas mixture and liquid containing suspended solid. Pump can usually be divided into three types of displacement pumps, power pumps and other types of pumps according to the principle of operation. In addition to classification according to the working principle, it can be classified and named according to other methods. For example, according to the driving method can be divided into the electric pump and the turbine pump; according to the structure can be divided into single-stage pump and multistage pump; use can be divided into the boiler feed pump and the metering pump; according to the nature of transmission fluid can be divided into water pump, oil pump and mud pump etc.. In accordance with the non axial structure, can be divided into linear pumps and traditional pumps.
- Q:What are the reasons for sealing damage of centrifugal pumps?
- Two, cavitation. Cavitation (mainly from a thermal centrifugal pump).Because the medium is hot water, the water temperature is too high to produce steam, the gas in the pipeline enters the pump cavity height, and the part of the gas can not be discharged, thus causing water shortage to run, the machine seal dry grinding is invalid, and the cavitation erosion device is not available.Process: replace the machine seal.
- Q:Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
- There should be the following reasons: 1) the setting value of the trip switch is too small, and the operating current of the submersible pump exceeds its setting value, and the switch is tripped
- Q:What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q:What are the conditions required for hydraulic pumps to complete oil absorption and compression?
- 2, the change of working volume is periodic, and in each cycle, the oil absorption process is changed from small to big, and the process of oil pressure is changed from large to small;3, suction oil cavity must be separated from each other without interference.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
P-2 inch self priming Centrifugal Non-clogging sewage pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 120 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords