                            Products Introduction

Product Description

Main datas:

     Capacity( flow rate) :  100 ~ 1270 m3/h

     Head  :4~43 m

     Speed:650 ~ 1250 rpm

     Impeller diameter:457.2 mm

     Pump weight:998 kg /1066 kg

     Power:20 ~ 175 hp

Advantage :

     Big pump body pass 76.2mmsolid ,high suction head 7.6 m

     Convenient repair and clean (a person ten minutes)

     Removable cover plate ,replaceable wear plate

     OEM ,L/C ,TT ,O/A ,D/P,D/A and so on

     CE ,TUV .ISO

NAME:  P-12 Self priming centrifugal Diesel Trailer Mounted Water Pumps

Standard SelfPriming pump units are available for Solids Handling or Clear Liquid

service. Typical mounting configurations are Engine Driven for Skid or Trailer Mounted

packages and Frame Mounted Electric Driven. Pumps also are available in a variety of different metallurgies.

1) Main Character

1.Beautiful shape and fine structure,reliable performance.

2.With strong capacity of delf priming, no need to equip with flap valve.

3.Non-clog, and with powerful capacity of passing big solid..

4.The hole can make sure that stronger sewage can be cleaned quickly when pump is jammed.

5.The unique lubrication oil mechanical seal cavity makes the performance more reliable.

6.Special check valve structure can make the pump working quickly.

7. When working, the gas and liquid  works together .

8. Low rotary speed,reliable operation,long time usage, easy to maintenance.

9.Advanced pressure protector make pump the pump work safe.


2) Application Area

1. Municipal project,  sewage project, instruction project.

2.Uptown,hospital, hotel sewage transportation.

3.Classification of municipal sewage factory treatment and concentrate system engineering.

4. Factory and contaminated water delivery.


3) Industries Served

♦ Construction

♦ Industrial

♦ Municipal

♦ Agricultural

♦ Mining

♦ Dewatering

♦ Industrial Waste

♦ Sewage

♦ Oil Field

♦ Petrochemical

♦ Paper Mills

♦ Processing


4)Parameter


1.Inlet/Outlet2''(50mm), 3''(75mm), 4''(100mm), 6''(150mm), 8''(200mm), 10''(250mm), 12''(300mm)
2.Impeller Diameter158.74mm-457.2mm
3.Rotary Speed550RPM-2150 RPM
4.Flow Rates8m3/h-1275m3/h20GPM-5500GPM
5.Head6m-63m
6.Horsepower1HP-125HP
7.N.W92KG-998KG
8.G.W114KG-1066KG
9.Solid Passing20.63mm-76.2mm
10.MaterialCast Iron, ADI, CD4MCU, 316 SS, Alloy 20, C276.
11.Diesel DrivingWater cooled or air cooled
12.Method of ConnectionSelf-priming pumps are available as basic units or may be flex-coupled, V-belt driven or engine mounted.
13.Drive VariationCummins, Deutz, Ricardo, Perkins or Chinese Diesel, Electric Motor
14.Skid Mounted on Trailer2 or 4 wheels Trailer/Trailor,Cart
15.PackageExporting plywood case
16.CertificationCE , ISO9001:2008 ,TUV



5) Mounting Configuration

♦ Frame Mounted

Base Mounted Electric Driven

♦ Engine Driven SAE Mounted

♦ Engine Driven Skid or Trailer Packages

♦ Horizontal or Vertical V-Belt Driven



5) Mounting Configuration

Frame Mounted

Base Mounted Electric Driven

Engine Driven SAE Mounted

Engine Driven Skid or Trailer Packages

Horizontal or Vertical V-Belt Driven

Packaging & Shipping

 

Our Services

 Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.

FAQ


The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure)
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.

Or the condition of pump station would be provided.

♦FAQ:

1.   Q: Can I know more about your products?

       

        A: Pls view our website: www.lanco.cc.

2. Q: What’s your MAQ of this item?

        A: 1~2PCS

3. Q: What is the lead time?

        A: 10~30 days after receiving your payment,depends on pumps.

4. Q: where is your loading port?

        A: Ningbo, China port

5. Q: Are you a manufacturer or trading company

        A: We are a manufacturer specialize in water pump and other pumps more than 20 years.

For more information, please contact me.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
Q:What is the difference between an air pump and a water pump?
The air pump (Q. B ng air pump), namely "air pump", a device for removing air or add air from the enclosed space from a closed space. The air pump is mainly divided into an electric air pump and a manual air pump. Electric air pump. An electric pump powered by electricity; produces air pressure by constantly compressing the air through electricity. Mainly used in pneumatic rubber, car inflatable, etc..
Q:Pump unloading in hydraulic transmission,
Unloading water, from the literal interpretation is along the pump, leakage of water seal through the head, the water with certain pressure (even with relief effect seal). The water as the working quality is asked to be recycled, now the design of some use it as a water seal, and others by direct recovery, but eventually recovered.
Q:Fire hydrant pump button, under what circumstances do not need to install?
General high voltage system, when normal, use small pump steady pressure.Fire hydrant button lifting pump is one of the multiple pumping methods, and it is an important link of reliable operation of the system.
Q:What happens when a centrifugal pump is selected?
First of all, the performance curve of the centrifugal pump is similar to the track of the train, and the train can not run away from the track.Secondly, the performance curves of centrifugal pump mainly include flow head curve, efficiency flow curve, power flow curve. When the pump is ready, the curve is fixed. In practical application, after determining the flow rate, the corresponding lift head, efficiency and power (relative to density) are determined. General requirements for centrifugal pump operating in the vicinity at the highest point of efficiency, the efficiency of the flow curve is similar to parabola, so if the actual operation condition deviated from the rated point, whether large or small, will cause the decline in pump efficiency (generally rated value is less than 15%), increased operating costs.
Q:The distance from the pump button to the ground
A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
Q:Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
Q:What is the pump, how to classify, mainly used in where?
2. other classification of pumpsThe pump can be divided into two parts according to the position of the pump shaft:1) vertical pump2) horizontal pumpDivided by the number of suction ports:1) single suction pump (single suction pump);2) double suction pump (double, suction, pump)According to the prime mover of the drive pump:1) electric pumps2) steam turbine pump3) diesel engine pump[other details]
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range