• P-10 self priming centrifugal sewage water 10 inches pump System 1
  • P-10 self priming centrifugal sewage water 10 inches pump System 2
  • P-10 self priming centrifugal sewage water 10 inches pump System 3
  • P-10 self priming centrifugal sewage water 10 inches pump System 4
  • P-10 self priming centrifugal sewage water 10 inches pump System 5
P-10 self priming centrifugal sewage water 10 inches pump

P-10 self priming centrifugal sewage water 10 inches pump

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
10 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                            Products Introduction

Product Description

Main datas:

    Capacity( flow rate) :   50-750 m3/h


     Head  :4-40 m

     Speed:650 ~ 1500 rpm


     Impeller diameter:375 mm


     Pump weight: 581 kg / 634 kg


     Power: 7.5 ~ 75 hp


Advantage :

    Big pump body pass 31.75mm solid ,high suction head 7.6 m

    Convenient repair and clean (a person ten minutes)

    Removable cover plate ,replaceable wear plate

    OEM ,L/C ,TT ,O/A ,D/P,D/A and so on

    CE ,TUV .ISO

NAME:Self priming 8 inch Centrifugal sewage diesel pump with trailer

Standard Self-Priming pump units are available for Solids Handling or Clear Liquid service. Typical mounting configurations are Engine Driven for Skid or Trailer Mounted packages and Frame Mounted Electric Driven. Pumps also are available in a variety of different metallurgies.

1) Main Character

1.Beautiful shape and fine structure,reliable performance.

2.With strong capacity of delf priming, no need to equip with flap valve.

3.Non-clog, and with powerful capacity of passing big solid..

4.The hole can make sure that stronger sewage can be cleaned quickly when pump is jammed.

5.The unique lubrication oil mechanical seal cavity makes the performance more reliable.

6.Special check valve structure can make the pump working quickly.

7. When working, the gas and liquid  works together .

8. Low rotary speed,reliable operation,long time usage, easy to maintenance.

9.Advanced pressure protector make pump the pump work safe.


2) Application Area

1. Municipal project,  sewage project, instruction project.

2.Uptown,hospital, hotel sewage transportation.

3.Classification of municipal sewage factory treatment and concentrate system engineering.

4. Factory and contaminated water delivery.


3) Industries Served

♦ Construction

♦ Industrial

♦ Municipal

♦ Agricultural

♦ Mining

♦ Dewatering

♦ Industrial Waste

♦ Sewage

♦ Oil Field

♦ Petrochemical

♦ Paper Mills

♦ Processing


4)Parameter

1.Inlet/Outlet2''(50mm), 3''(75mm), 4''(100mm), 6''(150mm), 8''(200mm), 10''(250mm), 12''(300mm)
2.Impeller Diameter158.74mm-457.2mm
3.Rotary Speed550RPM-2150 RPM
4.Flow Rates8m3/h-1275m3/h20GPM-5500GPM
5.Head6m-63m
6.Horsepower1HP-125HP
7.N.W92KG-998KG
8.G.W114KG-1066KG
9.Solid Passing20.63mm-76.2mm
10.MaterialCast Iron, ADI, CD4MCU, 316 SS, Alloy 20, C276.
11.Diesel DrivingWater cooled or air cooled
12.Method of ConnectionSelf-priming pumps are available as basic units or may be flex-coupled, V-belt driven or engine mounted.
13.Drive VariationCummins, Deutz, Ricardo, Perkins or Chinese Diesel, Electric Motor
14.Skid Mounted on Trailer2 or 4 wheels Trailer/Trailor,Cart
15.PackageExporting plywood case
16.CertificationCE , ISO9001:2008 ,TUV


5) Mounting Configuration

♦ Frame Mounted

Base Mounted Electric Driven

♦ Engine Driven SAE Mounted

♦ Engine Driven Skid or Trailer Packages

♦ Horizontal or Vertical V-Belt Driven


Prameter



5) Mounting Configuration

Frame Mounted

Base Mounted Electric Driven

Engine Driven SAE Mounted

Engine Driven Skid or Trailer Packages

Horizontal or Vertical V-Belt Driven

Packaging & Shipping

 

Our Services

 Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.

FAQ


The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure)
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.

Or the condition of pump station would be provided.

♦FAQ:

1.   Q: Can I know more about your products?

       

        A: Pls view our website: www.lanco.cc.

2. Q: What’s your MAQ of this item?

        A: 1~2PCS

3. Q: What is the lead time?

        A: 10~30 days after receiving your payment,depends on pumps.

4. Q: where is your loading port?

        A: Ningbo, China port

5. Q: Are you a manufacturer or trading company

        A: We are a manufacturer specialize in water pump and other pumps more than 20 years.

For more information, please contact me.

Detailed Images

 

Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
Q:Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
Q:What is a gear pump for?
Internal wear of oil pumpOil pump parts wear will cause leakage. The large leakage area between the floating axle sleeve and the end face of the gear is the main part of the inner leakage. This part of the leakage accounted for about 50%~70% of the total leakage. The pump efficiency of the gear pump is much lower than the input power when the gear pump is worn and leaked. All of its losses are converted to heat energy, which will lead to overheating of the oil pump. If the joint plane is pressed, the movement of the floating axle sleeve will cause a little wear and tear when the work is in use, so that the farm tools can be lifted slowly or can not be improved, so the floating axle sleeves must be replaced or repaired.
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
Automatic sprinkler, which is mostly used in this device or high water tank, the whole set of equipment must meet the most unfavorable point (the farthest the highest point of water) water pressure of the faucet.
Q:What kind of motor does the hydraulic pump need?
First count the flow: Q=dn L / minD displacement / revN RPM / minThen calculate the actual power: N=QP/ (60K) kwQ flow L / minP MPa MPaK total efficiency (usually 0.85)
Q:What does electromechanical vector pump mean?
Commercial buildings: hotels, office buildings, department stores, large saunas, etc.Irrigation: such as parks, playgrounds, orchards, farms, etc.Manufacturing: such as manufacturing, washing equipment, food industry, factories and so on
Q:The water tank of the fish tank does not air out and only has the water outlet
The picture above is very clear, but I didn't say anything about it. My problem is solved. The intake pipe and the exhaust pipe are connected by the inverted T type. The intake pipe is upward, but not fixed. It can be rotated. The intake pipe can be rotated to adjust the number of bubbles
Q:What is the pump, how to classify, mainly used in where?
Classification of pumpsAccording to the principle of division:1. displacement pumpDepending on the movement of the work parts, the volume of the work increases periodically and reduces the suction and discharge of the liquid, and the pressure of the liquid increases directly by the extrusion of the working partsAccording to the different movement of moving parts, it can be divided into two types: reciprocating pump and rotary pumpAccording to the structure of the moving parts are different: piston pump and piston pump; there are gear pumps, screw pumps, vane pumps and water ring pump
Q:Operating procedures for measuring pumps
Pressurization(1) for the discharge pressure below 2.0MPa, then the pump stroke length should gradually increase, each increase of 20%, to maintain 15 minutes.(2) for the discharge pressure greater than 2.0MPa, you need a special pressure, to ensure that the pump discharge pressure gradually increased, each time for the final row pressure of 20%.(3) when the pressure is not increased, the stroke of the pump is gradually increased by 20% strokes per time.Note (1) when pressure is applied, the pressure gauge should be observed at the side of the loading side (slow motion)(2) check ammeter, forbid overload
Q:Why should I pump the pump before starting the centrifugal pump?
Before the operation of the centrifugal pump, the pump must be filled with water, exhaust the air, before you start the operation. All centrifugal pumps should be handled this way, which is the centrifugal pump itself.The way of water diversion:1., in the centrifugal pump outlet increase water diversion pump (usually using vacuum pump), start the centrifugal pump before, start the vacuum pump, the centrifugal pump air into;2. increase the vacuum water tank before the intake of the centrifugal pump to meet the working conditions of the centrifugal pump;3. in the centrifugal pump inlet water increase valve, to meet the working conditions of centrifugal pump;4., if the water tank or water tank volume of water level is higher than the centrifugal pump position, the first operation of the front row empty, usually do not empty, you can use.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords