Outdoor UPS HW9110E Series

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
2 Pieces pc
Supply Capability:
30 Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

Key Features

 

1.  Providing with pure sinewave power for outdoor telecom and network equipment.

 

 2.  Be suitable for outdoor severe Temperature,Humidity and harsh Environment, especially can meet the outdoor electric network requirements. (Outdoor environment is severe and quality of electric network also is so bad . For example outdoor high temperature is 50 and severe winter is 40,Voltage range is from 160V to 260V even easily change )

 

 3.  Adopting sealed natural cold design, high-temperature resistant ,cold resistant and corrosion resistant,that degree of sealing is IP55 .

 

Model

HW9110E  1-10KVA

1KVA

2KVA

3KVA

6KVA

10KVA

Capacity

1KVA/800W

2KVA/1600W

3KVA/2400W

6KVA/4800W

1000KVA/8000W

Nominal voltage

220/230/240VAC

Nominal frequency

50/60HZ

Input

VoltageRange

115~295VAC(±3VAC)

176~297VAC(±3VAC)

FrequencyRange

50HZ(46~54HZ),60H(56HZ~64HZ)

Power Factor

0.98

Output

Voltage Precision

220/230/240X (1±2%)VAC

Frequency Precision

50/60HZ±0.05Hz

Power Factor

0.7/0.8(optional)

Wave Distortion

Linear load<3%        Non-linear load <6%

Overload capability

Overload (110% ~ 150%) for 30 seconds,then automatically transfer to bypass.When load is normal,it can automatically transfer to normal mode.

Crest factor

3;1

Transfer Time

0ms(AC to DC )

Battery

DC supply voltage

36VDC

96VDC

96VDC

240VDC

240VDC

Charge current

4A/8A(optional)

4A/8A(optional)

4A/8A(optional)

4.2A

4.2A

Internal battery capacity

(38/65/80/100AH)optional

Panel display

LCD

Display input and output voltage, frequency, battery voltage, battery capacity, load percentage

Communications

communicate interface

RS232,SNMP card(optional)

Work environment

Temperature

0~40°C

Humidity

0~95% Non-condensing

Storage temperature

-25°C~55°C

Elevation

<1500m

Acoustic Noise ( within 1 meter)

<50dB

Physical Characteristics

Weight(KG)

 

85

125

125

150

155

Dimensions   ( Wx D x H )mm

640×900×900

640×900×1185

640 ×900×1185

940×940×1770

940×940×1770

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
Q:Why should lighting transformers be used in factories and mines?
There are two cases. One is the general factories and mines, and the low voltage is three-phase four wire system, and the neutral point is directly grounded. Between the phase line and the zero line is 220V, which can be connected with the illumination load.
Q:How is the lighting power of the 380V transformer calculated?
With a light bulb with 4KVA load, the premise of the distance can be Mrs. face light bulb, dark can light the best load, 3KVA bulb brightness
Q:What transformer can be used in a safety voltage lighting transformer?
220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
Q:How many A leakage protection switches are used in 5000VA lighting transformers?
According to the working principle of the protector, it can be divided into three kinds: voltage type, current type and pulse type. The voltage protection device is connected to the transformer neutral point and the ground, when the electric shock when the neutral point voltage offset to the real estate, in order to make the action to protect the power off, but because it is the protection of the transformer low voltage network, cannot be classified protection, so the power range is large, frequent moves, so has been eliminated. The pulse current protector is a sudden change in the phase and amplitude of the three-phase unbalanced leakage current when an electric shock occurs, which is used as an action signal, but also a dead time. The current type current leakage protector is widely used, so the protector of current type is mainly introduced below.
Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
Line lights, lighting transformers in general how many low voltage, can live operation, but to do safety measures. For example, do not short-circuit, damp environment, wear insulation shoes, wearing insulating gloves and so on.In fact, all the voltage levels, as long as safety measures can be done live operation.
Q:Is the substation separate from the power and illumination transformer?
The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
So, safety regulations: lighting transformer must double winding type safety isolating transformer, prohibited the use of autotransformer.
Q:Can the 500 volt lighting transformer be changed into an electric welder?
The no-load voltage is higher (about 70~90 V), the arc can be smoothly started, and the voltage will be reduced to about 30 V when welding.
Q:What type of low voltage transformer should be adopted for safety lighting power supply?
Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications.if you have interesting, please kindly contact us! We will provide our good quality products and best services to you!

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2006
Annual Output Value US$10 Million - US$50 Million
Main Markets 9.09% North America
9.09% South America
9.09% Eastern Europe
9.09% Southeast Asia
9.09% Africa
9.09% Mid East
9.09% Eastern Asia
9.09% Western Europe
9.09% Southern Europe
9.09% South Asia
Company Certifications UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen China
Export Percentage 61% - 70%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average