Product Description:

Basic tech datasheet  

UPS Model

EX1K

T1K

EX2K

T2K

EX3K

T3K

Capacity

1000VA/700W

2000VA/1400W

3000VA/2100W

Input

Voltage

(115~300) VAC

Frequency

46~54Hz/56~64Hz (Adjustable via LCD panel)

Output

Voltage

220/230/240 (1±1%) VAC (Adjustable via LCD panel)

Frequency

50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode:50Hz (1±0.2%) 60Hz AC Mode:Follow AC Mode(AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%)

Output Wave Form

Sine Wave

Back-up Time

Full Load

≥5′

≥9′

 

≥5′

 

Half Load

≥14′

≥21′

≥15′

Battery Nominal DC Voltage

36VDC

96VDC

Transfer Time

0ms

Overload Capacity

110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms

Communications

RS-232+Intelligent Slot

Environment

Temperature

             0C~40C

Humidity

             15%~90%

Dimensions (W*D*H)mm

400*145*220

460*192*348

460*392*348

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why should lighting transformers be used in factories and mines?
But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
Q:How many A leakage protection switches are used in 5000VA lighting transformers?
AC circuit transformer for lighting lamp is suitable for 50-60Hz, is the power supply with safety shell low-voltage safety lights, can choose 220V or 380V power supply input voltage: 0V, 220V, 380V, 0V, 6.3V, output voltage: 12V, 24V, 36V.
Q:Why is elevator lighting transformer installed?
3 a power outlet shall be provided at the bottom pit.4 the cables and wires laid in the hoistway shall be flame retardant and damp resistant, and shall be protected by a nonflammable wire, conduit, or wire slot, with no use of wires, conduits, or wire slots made of combustible material.5 an elevator attached to a building whose wiring, materials and methods and electrical components used shall take into account the effects of climatic conditions and shall take waterproof measures.Lighting transformers in order to obtain 36V voltage
Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
220V500W more power saving:Reasons: 1, high voltage, small current, line loss is small; 2, reduce the transformer and other intermediate links, each link has a loss.
Q:Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q:How to calculate the rated capacity of small transformers for lighting purposes?
Capacity of power transformer is the basic equipment for a total capacity of [kW] (maximum power consumption rate by a / X100 capacity) divided by the power load [%] value for benchmarking.
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
Q:How many 40W bulbs can be brought into the 1000VA lighting transformer?
Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
Q:What transformer can be used in a safety voltage lighting transformer?
220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
We are now looking forward to your kind cooperation, and will be highly appreciated for that. We sincerely hope to cooperate with you in the lighting field. Please don't hesitate to contact us at your convenience.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range