• Multistage Centrifugal Pump with High qualities System 1
  • Multistage Centrifugal Pump with High qualities System 2
Multistage Centrifugal Pump with High qualities

Multistage Centrifugal Pump with High qualities

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

FEATURES:

Vertical Multistage grundfos water Pump is the latest model with the features of energy-saving and less space demand, easy to install and has stable performances.

 

1. With its 304 stainless steel shell and wear-resistant axle seal, there is no leakage and it can live long service life.

 

2. With hydraulic equilibrium to balance the axial force, the pump can run more smoothly, less noise, which can be easily installed in same level pipelines, enjoying better installation conditions than DL model.

 

3. With these features, GDL Pump can easily meet the needs and requirements for water supply and drain foe high building, deep well and firefighting equipments.

 

Flow range:                                       1.4-1 94.4CBM/h

Head range:                                      20-230m

Speed:                                               2900r/min

Maximal pressure of system:           2.5MPa

Medium temperature:                      -15~°C+120°C

Environment temperature:               ≤+40°C

Motor protection level:                     IP44, IP54

Insulation grade:                              B, F rank

Rotation direction:                           Clockwise

 

APPLICATIONS:

Domestic water supply for buildings

Fire water supply for buildings

Water supply equipments

Water supply for boilers

Water circulation and boosting for industry

Other clean fluid transportation

 


Q:Double floor sewage pump circuit diagram of a small problem
Q 2, SA and SS are select switches, and different positions indicate the same difference between the two nodes. SA hits the left position 13, 14 to connect, hits to the right position 21, 22 to connect. SS hit the middle position, 5 and 6 turn on, 7 and 8 turn on; hit the right position; 1 and 2 turn on; 11 and 12 turn on; hit the left seat; 9 and 10 turn on; 3, 4 turn on.
Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
As the name suggests, centrifuges are machines that achieve centrifugal effects by centrifugal action. And you say the centrifugal pump is only specific, and the same as the pump
Q:How is the pump level of submersible sewage pump determined?
Generally as:The bottom elevation of sump sump plus 300 is the water level of pump stopThe top 300 of the sump top elevation is the pump water level
Q:How many square cables does the submersible pump for 7.5KW need?
7.5KW's submersible pump requires 2.5 square aluminum cables.Calculate the current value of submersible pump first:
Q:How high can the pneumatic diaphragm pump be?
If the pump material made of polypropylene (PP) material, corrosion resistance, good chemical resistance using PP material produced by pneumatic diaphragm pump can resist medium low cost, good generality, polypropylene material mainly is especially suitable for general acid-base liquid, using poly propylene made of plastic gas diaphragm pump can only withstand the highest temperature to 65 degrees, more than this number of polypropylene plastic deformation.
Q:Why can't the inlet of centrifugal pump be negative pressure?
However, the centrifugal pump will have its import pressure requirements, which is to prevent cavitation, that is, the fear of the delivery of liquid at low pressure will occur gasification. Centrifugal pump has an important parameter called NPSH, for example relating to the inlet pressure, the pump NPSH, 4 meters, it means that the absolute pressure of imports should be higher than the saturated steam conveying fluid pressure of liquid column is 4 meters high, so, when it is at a temperature of saturated vapor pressure for water transport 2 meters, 4+2=6 meters minimum inlet absolute pressure. Because the absolute pressure is 10 meters water column atmospheric pressure, at this time the entrance negative pressure is 10-6 meters =4 meters water column.
Q:What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
Important equipment for deep well water extraction. When in use, the whole unit dives into the water. The extraction of groundwater to the surface is water, mine rescue, industrial cooling, irrigation, water lifting, ship ballast, also can be used in fountain landscape, hot water submersible pump for hot spring bath, but also can be applied to the extraction of groundwater from wells, can also be used in rivers, reservoirs, canals and other water projects. The utility model is mainly used for farmland irrigation and water for human and livestock in mountain areas, and can also be used for central air conditioning cooling, heat pump units, cold pump units, cities, factories, railways, mines and site drainage. General flow can reach (10m3~650m3) per hour, head up to 1500 meters.
Q:I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
15MPa. 20MPa means that if you enter the 20MPa, the variable mechanism will work, and the flow at this time automatically matches the load. 20MPa used to supply the fuel by maximum displacement.
Q:What are the ways of hydraulic pumps?
Check valves, such as single piston pumps, three piston pumps, etc.;The port of the valve arrangement, such as the radial piston pump.
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products