Moving Walk

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Set set
Supply Capability:
6000 Sets per Year set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Detailed Product Description

1.Modern designing and styles

2.Can operate normally in outdoor environment

3.Handrails with rich colors

 

\With many years' development, we have developed into a very potential vertical transportation equipment manufacturer.

Regarding customer satisfaction as our basic responsibility and providing excellent service, we have

attained ISO9001:2000 certification and also CE certification for MR elevators, MRL elevators &

escalators. In brief,

we would like to meet extra demands and are able to make every building more beautiful with more comfort and culture

enjoy by offering a full and comprehensive range of products.

Specification:

GRM15-I series of moving walk with 110-metar maximum horizontal length can operate normally in outdoor environment.

  

Application

Indoor. 16-hr operation daily

Horizontal span(m)

≤150

Inclination(°)

0-6

Step width(mm)

800/1000

Horizontal steps

/

Speed(m/s)

0.5

Capacity (per./h)

6750/9000

Main power

380V/50Hz/3P

Balustrade

Tempered glass(10mm)

Handrail bracket

Stainless steel

Handrail

Black

Balustrade height(mm)

900

Inner & outer decking

Hairline St.St.

Skirting

Wear resistant coating steel sheet

Step

Stainless steel

Landing plate

Stainless steel (anti-sliding)

llumination

lighting under upper & lower landing pallets

Indicator

Failure code indicator on control cabinet

Operation

Emergency stop button

Key switch

Inspection operation

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to save the elevator
I am engaged in maintenance, you say this situation is very rare, very little, do not know? There is a possibility, that is overload, so advise you not to squeeze the elevator. Normally the elevator will not fall. Even if it is overloaded fall, nor is you imagine the free fall, as the speed will not be very fast. The elevator has a lot of protection devices, even if the same protection device failure, can not fail at the same time, so the elevator is safe, the elevator for more than 100 years, you heard someone in the elevator from falling above the fall of the people? No. The elevator has to kill people, but are not falling when people died in the elevator, dead mostly elevator workers. Belong to the illegal operation, their own play dead. So the elevator failure, do not panic, stay inside do not tamper on the line, no life dangerous. As for the TV on the knees to bend like, no need. Right is immediately by the elevator phone keys, notify the professionals to deal with. Do not arbitrarily Pa door, tamper with the like. If the phone is unreasonable, mobile phone, mobile phone nowhere, pat on the car door, propaganda. Hope to adopt. Thank you
Q:Why take the elevator tinnitus
I think it is not the tinnitus but the eardrum outside the drum Department of the bones of the body of the body of the body or concave concave.When the rise or fall due to lower pressure caused by the original internal and external balance of the pressure changes, so the eardrum changes, resulting in tinnitus may be eardrum deformation result.
Q:Why is the gearless traction machine installed in the elevator?
It will not slip car!
Q:Conan has a set is the body hidden in the elevator, which is caused by overload ah
050 library killings this episode has a little bit of horror, hope can help you!
Q:What is the meaning of the upper limit of the ceiling?
To prevent the elevator out of control, in the end also put the wire, or to the top of the winding wire, or to the door that the reaction was slow, the elevator stopped in the middle of the floor, are limiter tube limit switch can be divided into upper and lower limits, Simply put on the stop switch and stop the switch. General limit and slowdown switch, limit switch installed together, from high to down in order, the upper limit - upper limit - on the strong reduction. The elevator pit and the top floor of the other group. When the elevator to run to the top of the time (from bottom to top), if the speed is very fast, will first encounter on the strong reduction, that is forced to slow down, the elevator began to slow down, and then hit the upper limit, this time the elevator should stop, Fast, it will encounter the last safety switch, the limit, this time the elevator safety circuit open, the elevator in the shock state, there will be crowded, if the speed soon soon, continue upward, this time the governor action, security Clamp the guide rails. The elevator stops.
Q:Will the elevator door sets how to calculate the area?
Long by the width of the area, or the amount of length,
Q:What is the ox in the elevator shaft?
Can do it. Is a fixed use of the ground, is necessary to have, or the elevator side to do. Just the money.
Q:What is the meaning of elevator fire linkage?
Elevator fire linkage, refers to the fire alarm, the fire building all the elevator will be forced to the first floor. Elevator in the first floor of the fire switch, and fire linkage has nothing to do, in two cases: First, the fire is not set up automatic alarm building, elevator landing, the direct start of the first floor of the fire switch; Second, set up a fire alarm system Building, when the elevator down the function of failure or failure, you can directly start the first floor of the fire switch to start landing.
Q:Elevator industry, the traction machine has permanent magnet synchronous motor and permanent magnet asynchronous motor two, what is the difference between them?
AC motor to rotate requires two conditions: first, there is an active rotating magnetic field; second, there is a magnetic field driven by this active magnetic field. In general, the rotating magnetic field from the stator winding, three-phase AC power naturally formed a rotating magnetic field. The difference between a synchronous motor and an asynchronous motor lies in the source of the rotor magnetic field. The synchronous motor requires an excitation power source, or a permanent magnet, so that the rotor always has a magnetic field that can be driven by the rotating magnetic field provided by the stator. As long as the braking torque is reasonable, the final rotor speed can always reach the stator in the rotating magnetic field speed, that is, synchronous speed. This kind of motor is synchronous motor. Asynchronous motor is simply closed end of the whole family is relatively simple. The magnetic field of the rotor is derived from the rotating magnetic field provided by the stator windings to cut the current generated by the conductor in the rotor. In other words, the induced current generated by the rotating magnetic field cutting rotor from the stator produces a second magnetic field based on the rotor, and the rotor rotates due to the interaction of the two magnetic fields. The greater the difference in speed between the rotor and the rotating magnetic field, the greater the rotor current, and the stronger the effect of the two magnetic fields. As the speed increases, the rotor current is getting smaller and smaller, but never. This creates that the rotor speed must have a certain difference from the synchronous speed to maintain the rotating magnetic field to cut the rotor conductor. To maintain the continuous rotation of the rotor. The difference between this speed and the speed of synchronous speed is the slip rate. Asynchronous motor speed never reach the synchronous speed, so called asynchronous motor
Q:What is the elevator room
The floor is high and the building is equipped with an elevator.
We have introduced production facilities and inspecting equipments with advanced world levels from Germany, Italy and other countries, so that keeps a manufacturing capacity about 40,000 sets as annual output, which is a large-scale and modern manufacturing enterprise, facing the global market for elevators, escalators and parking system equipments.

1. Manufacturer Overview

Location Zhejiang,China (Mainland)
Year Established 2007
Annual Output Value Above US$100 Million
Main Markets 90.00% Domestic Market
2.90% Southeast Asia
2.10% Eastern Asia
1.50% South America
1.20% South Asia
1.00% Africa
0.60% Mid East
0.50% Central America
0.20% Oceania
Company Certifications Machine Roomless Passenger Lift CE Certificate; Passenger Lift CE Certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai port
Export Percentage 11% - 20%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese, German
b)Factory Information  
Factory Size: Above 100,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average