Metal shielded flame-retardant Power Cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.      Application

This product is suitable for rated voltage 0.6 / 1kV and below of transporting electricity. This product has a strong anti-electromagnetic interference,anti-lightning and a uniform electric field, improve power quality characteristics. Especially for sophisticated electronic device places, such as computer center, aerospace monitoring center, intelligent building. 


2.      Type and Specification

 Voltage

0.6/1 kV

 Type

Z-VV-P2、Z-YJV-P2、Z-VLV-P2、Z-YJLV-P2、Z-VV22-P2、Z-VV32-P2、Z-VV42-P2、Z-YJV22-P2、

Z-YJV32-P2、Z-YJV42-P2、Z-VLV22-P2、Z-VLV32-P2、Z-VLV42-P2、Z-YJLV22-P2、Z-YJLV32-P2、

Z-YJLV42-P2

 Specifications(mm2)

1 Core:4~300;

2 Core:4~185;

3、 4、 3+1 Core: 4~300

 Standard

 GB/T 12706-2008


3.      Using features

①    Rated voltage Uo/U 0.6/1 kV.

②    The permissible maximum conductor operating temperature: XLPE insulated 90 ℃, PVC insulated 70 ℃.

③    Cable short circuit (the longest duration of no more than 5s), the maximum temperature of the conductor: XLPE insulated cable 250 ℃, PVC insulated cable 160 ℃.

④    Laying the ambient temperature should not be less than 0 ℃, should be less than 0 ℃ pre-heated. Cable bending radius: Single cable without armor no less than 20 times the cable diameter, armored not less than 15 times the cable diameter; multi-core cables without armor is not less than 15 times the cable diameter, armored not less than 12 times the cable diameter.

⑤    Finished cable should be subject to 2.5U0 + 2kV power frequency voltage test 5 min without breakdown.

⑥    DC resistance of conductor at 20 ℃ comply with GB / T 3956.

⑦    Finished cable with anti-electromagnetic interference, anti-lightning and other characteristics.

⑧    Cable flame-retardant characteristics comply with the requirements GB / T 19666. 


4.      Picture of structure


1、Conductor   2、Insulation  3、Filler   4、Tape  5、Inner Sheath   6、Metalshield   7、Outer Sheath


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:high effency double shielded transmission power cable?
What is your question? Does such a cable exist? Probably but you'll have to be more specific. High efficiency = low loss or low resistance per foot? Double shielded = is the shielding (in dB) critical? Transmission = What frequency, 60 Hz, 1 MHz, 100 MHz, ? Power = Watts, KW, MW Is weight or cost important?
Q:A network cable must cross a power cable. What can be done to minimize the amount of EMI?
Metal shielding would be best. This could be as simple as wrapping each cable with aluminum foil near the cross-over point. Hope this helps.
Q:How to install more 6pin power cables?
You okorder.com/
Q:What is the best way to bundle audio cables?
any cable with an electrical current passing through will create an electromagnetic field. however when you bundle them in a single loop, because the currents are going in the same direction they will resemble a very big cable with a lot of current, so the magnetic field will be much larger (this is in part how an electric motor works). the best way to avoid this would be to remove excess cable so there would be no need to have loops. Really i'm not convinced about the benefits of having the cable in a figure 8 pattern, because it's just like having two loops really. i would try to avoid loops, or at least keep them away from the actual hifi and the speakers. generally components in your hifi and speakers will be magnetically shielded, to prevent any interference like that, however if you hear a buzzing noise when your mobile phone is near, than it's possible they're not shielded, as your mobile phone is a source of electromagnetic interference. if you're worried about electromagnetic interference it is also worth noting that wifi routers, mobile and cordless phones and microwaves are all sources of electromagnetic radiation. hope that all helps
Q:30 on the large number of cable how to fight on the 110 patch panel, how to order, please inform, thank you, which
Is the size of the power cord size, that is, the thickness of the power line diameter, 4 square power cord diameter is 2.2 mm thick, the safety current between about 25-32A, that is, can withstand electrical power at 5500 watts or .000 watts Depends on the laying of the power cord, that is, the laying of dark lines or laying the line, the size of the safe current is not the same. Generally more than 2 air-conditioning use 2.5 square copper wire, 2 or more air conditioning should use 4 square copper wire.
Q:2000 hyundai elantra only starts after moving power cables?
I with Michael on this. take of your leads clean them and put them back on good and tight and you should be good to go.
Q:Where in the US can I get power cables for the smaller electrical appliances?
try the internet
Q:Is there a hdd power cable with a MALE 4-pin connector that extends into one female 4 pin connector and one..?
Probably, but most people just buy Molex to SATA power adapters. If you need more Molex 4 pin plugs, just buy some Y splitters. Any computer store worth a darn should have some of both in stock, even the chain ones.
Q:Dell Inspiron M5030 power button cable?
Hope this helps. Regards, GauravS
Q:i have a laptop, and the socket where the power cable goes, stopped working.?
This is a common problem with the technology. Our shop charges 150.00 to resolder the jack on. You have to completely remove the motherboard from the case inorder to properly fix the jack. This problem will repeat with time so extra care should be taken then using AC Power.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range