Medium Voltage Drive VFD 630KW 6KV HIVERT-Y 06/077

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Perfect Power Output Section

The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:

1. No need for the additional output filter

2. Directly driving general synchronous or asynchronous motor

3. No de-rating operation on the motor

4. No dV/dt stress on the insulation of motor and cables

5. No torque ripple, extending service life of motors and mechanism

6. No cable length restriction within the acceptable voltage drop.

The general MV VFD has the following protection functions and features:

Overload and over-current

Phase loss and grounding

Over voltage

Overheat

Current limit

Redundant control power supply

Cell Bypass (optional)

Cabinet door alarm

Phase-Lock function

Synchronous Switching between VFD and Grid system

Soft start of motor

High efficiency >98% (VFD at full-load)

Electrical Isolation by the optic fiber

Built-in PID regulator

RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc

Accurate fault records, easy to check fault history

 Compact structure and layout, customized design is available

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Speed regulation method of three - phase asynchronous motor
1, frequency control, with the inverter, power 2, change the magnetic pole logarithm, not feasible. 3, stator series resistance, energy consumption
Q:How does the spindle drive system of the inverter realize the positive and negative control of the main pole?
Communication can reach a longer and more stable, generally better of the city 485
Q:Inverter alarm a043, how is it
Check processing: Check if the cable is disconnected. Check the tachometer to shield the ground. The shield is not only on the motor side, but also on the inverter side The cable of the pulse encoder should not be disconnected. The pulse encoder cable can not be laid together with the power loop cable. Use only the recommended pulse encoder.
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
Q:Laptop adapter
This principle is not, try, look at how the charge situation, if you can charge, can be filled, just a long time, to no harm However, the heat may be high, long-term so, there is a risk
Q:Laptop power adapter how to detect?
No voltage output when no load.
Q:What is the common COM point of the PLC and the inverter? Is it positive?
Plc is divided into two kinds of transistor output and relay output, com side may be connected to the high level may also be connected to the low level, the general input com port then low, the output port com mouth high, specifically what to take See the data sheet. Inverter is the same, the inverter has 24v com side and 10v com side, can not be connected together, com side generally low.
Q:Fuji inverter motor set the number of poles will not have any effect?
The number of poles is not the same as the speed is not the same mistake machine can not work or motor coil burned
Q:If it is 8-pole variable frequency motor, enter the motor nameplate parameters in the inverter input for the 4 pole can?
According to the number of revolutions N = 60 * f (frequency) / p (pole pairs) can calculate the motor is a few poles. If the motor is 8 pole is not recommended in the inverter set to 4. will certainly affect the control accuracy.
Q:How to view your own laptop power adapter is how much tile?
There are signs on the power adapter, you look for sticky paper to write the voltage and current power. If there is no write power, the direct voltage multiplied by the current is the maximum power.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range