Manufacturers supply on the spot YJV3X2. 5 power cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
500000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

The following) insulation materials Plastic insulated power cable

 

• crosslinked PVC insulated power cable

 

1, the products according to national standard GB/T12706-2002.

2, partial discharge test: rated voltage Uo to 18 kv and below cable discharge < 20 PC; Rated voltage Uo to 18 kv cable discharge < 5 PCS. .

3, 20 ℃ conductor dc resistivity: copper 0.017241 or less Ω was/mo aluminum core 0.028 or less Ω was/m.

4, combustion performance, flame retardant cable) tested according to GB/T18380-2001 standard.

Product performance:

 

 

Using features: 1, the cable's highest working temperature is 90 ℃ for a long time.

2, when the ambient temperature under installation should not below 0 ℃, the cable bending radius should be more than 20 times of cable diameter.

3, in the event of a short circuit, the highest temperature of the conductor shall be no greater than 250 ℃, the duration of not more than 5 seconds.

4, temperature under installation should not below 0 ℃.

5, short circuit, the highest temperature of the conductor shall be no greater than 160 ℃, the duration of not more than 5 seconds.

6, cable used in rated voltage, 1.8/3, 3.6/6, 6/6, 0.6/1, 6/10, 8.7/10, 8.7/15, 12/20, 21/35, 12/20 kv power transmission and distribution system.

7, YJV YJLV is suitable for indoor and outdoor installation, can withstand a certain installation drawing, but unable to bear external mechanical forces. Single core cable in ferromagnetic materials duct is not permissible. YJV22 YJLV22 applies to direct buried, able to bear external mechanical forces, but unable to bear large pulling force.

 

Model and name: model Type

The name of the Description

 

YJV

Copper cross-linked polyethylene insulated PVC sheathed power cable

 

YJLV

Aluminum conductor crosslinked polyethylene insulated PVC sheathed power cable

 

YJV22

Copper core with cross-linked polyethylene insulation tape armored PVC sheathed power cable

 

YJLV22

Aluminum conductor with cross-linked polyethylene insulation tape armored PVC sheathed power cable

 

 

Production range: model

some

KV rated voltage

 

0.6/1

1.8/3

3.6/6, 6/6

6/10,8.7/10

8.7/15 ~ 12/20

18/20 ~ 26/35

 

Conducting wire core of nominal section was

 

YJV

YJLV

1

1.5 ~ 800

10 to 800

25 ~ 1200

25 ~ 1200

35 ~ 1200

50 ~ 1200

 

3

1.5 ~ 300

10 to 300

25 ~ 300

25 ~ 300

35 ~ 300

-

 

4

4-240

-

-

-

-

-

 

YJV

YJLV

1

2.5 ~ 1000

10 to 1000

25 ~ 1200

25 ~ 1200

35 ~ 1200

50 ~ 1200

 

3

2.5 ~ 300

10 to 300

20 ~ 300

25 ~ 300

35 ~ 300

-

 

4

-

-

-

-

-

-

 

YJV22

YJLV22

-

-

-

-

-

-

-

 

3

4-300

4-300

25 ~ 300

25 ~ 300

35 ~ 300

-

 

4

4-240

4-240

-

-

-

-

 

YJV23

YJLV23

-

-

-

-

-

-

-

 

3

4-300

4-300

25 ~ 300

25 ~ 300

35 ~ 300

-

 

4

4-240

4-240

-

-

-

 

 

 


 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between KVV and VV cables and are they clearly different?
Is there a problem driver in Device Manager? Should be driven by the problem
Q:Calculate the control cable under what circumstances the cable terminal needs to be calculated
" Why should the closed wall or protective wall closed on the second side of the closed junction box? This need to understand if you do not add this closed junction box, what kind of harm Civil air defense project in the closed wall is divided into the clean area and the area of ​​the infected area, and the wire tube in the thread after the inside is a cavity, directly through the wall to communicate with the cleaning area and exposed areas, so wartime works outside the dyeing The poisonous air can penetrate into the clean area through the cavity inside the wire tube, which is harmful to the personnel inside the project And the installation of a sealed junction box, you can thread in the line after the box filled with sealing material to block the tube cavity connectivity This is why the electrical safety pipe in the air defense project must pass the closed wall or protect the closed wall when the two sides must be closed in the closed junction box reasons
Q:The computer host is always start to stop, resulting in the last can not start. What is going on?
GB-2002 provides: metal cable bridge and its bracket and the introduction or extraction of metal cable ducts must be ground (PE) or zero (PEN) is reliable, and must meet the following requirements:
Q:110 voice patch panel directly to the telephone line can be connected to it
sure. Take the ground pipe is to be from the floor under the brick. But the late completion of the drawing to be accurate, so that the next time to repair the line can not find the location. Want to answer to help you.
Q:Hello, ask about how to charge the electric car at home, use a few square millimeters of wire? How high is the demand for family lines, thank you!
PLC and computer communication cable, different manufacturers of PLC connection is not the same
Q:Engineering materials inspection, all types of cable wires should be issued a test report?
Buy a distributor on the line, the computer city generally have
Q:Power cable casing buried what are the requirements
1 It is advisable to select the route to lay the cable in a suitable way: 1 Avoid the area where the corrosion of the acid, alkali, or stray current is seriously affected by electrochemical corrosion
Q:What recycled rubber is suitable for the production of wire and cable?
Need to choose according to specific circumstances. The main difference between single and multi-core is the flexibility of the wire. In fact the two do not exist which good question, but the use of the environment is not the same. Home decoration: First, the lighting line, can be used 1.5 single strand copper wire. . 2P (inclusive) or more of the air-conditioning, that is, hot water heater, Yuba must use 4 square double strand copper wire; Third, the wall buried the best choice for single wire copper wire, you can choose according to the need for 4 square Mm, 2.5 square millimeters, 1.5 square millimeters and other specifications (usually 2.5 square millimeters with the most). Fourth, the remaining lines, are using ordinary 2.5 pairs of copper wire can be.
Q:What are the lines that need to be set up for notebooks?
Friends, shielded cable is a layer of mesh copper or metal wire woven from one or more wires surrounded by a cable, this layer of mesh to prevent lightning, the outside signal can not interfere with it, and control cable is used To control the device to start the protection circuit, etc., in general occasions do not need to shield, with the general insulated wire on it, as long as the load on the line.
Q:What is the length of the wire that affects voltage and electricity
Can go if you do not trust to wear a pvc into the bridge on it

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range