Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
50 set
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Structure of  Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

The CXF series of vertical axis maglev wind turbines undergoes a continuous improvement process, which incorporates exterior design, utility design, electrical engineering, dynamic engineering, power mechanics, aviation air engineering, wind tunnel testing, lightening protection, computer simulation techniques and other multiple specialities. Under the light theory of magnetic levitation technology, fan motor will be rotated by wind power without any mechanical friction.  Since the generator has no lubricant and no gear, the Magleve wind turbine are high-performance power generation, smooth operation, which is a milestone for a new age of power technology.

 

 

2. Main Features of Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

 

* Ideal for both of residential and commercial applications as well as off grid and on grid power systems.

* The unit provides a durable, reliable, and fully customized hybrid solution to Telecoms Base Receiver Station (BTS), Charging Station by Solar and wind  and also very suitable for power supply to home

* Intelligent control system with active protective functions

* automatically lower rotational speed during strong winds

 

3.Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Specifications:

 

tems

CXF600

Rated power

600W

Dimension (Height/Diameter)

Ø1540mm / 1320mm

Weight

50 kg

Blade material

Aluminum Alloy

Blade quantity

7 (3 Darrieusand 4 Savonius)

Swept area ㎡

0.30

Min starting wind speed

1.3 m/s

Cut-in wind speed

3.5m/s

Rated wind speed

13m/s

Cut-off wind speed

15m/s

Survival wind speed

60m/s

Generator type

AC,3Phases

Controller Output Voltage

24V/48V

Controller Braking System

3-phase short circuit by NFB brake

Ambient Temperature

-40~50 ℃

Noise

Less than 40dB

Annual Energy Production                 (@ 5 m/s wind speed )

about 1500 kWh

 

 

 4.  Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V Images

Maglev Vertical Axis Wind Turbine for Home Use 600W-24V/48V

 

5. FAQ

 

  1. Why to choose vertical axis maglev wind turbine ?

Re: You can find the answer in the following table

Comparison between HAWT AND MVAWT

Item

Horizontal axis wind turbine (HAWT)

Maglev vertical axis wind turbine (MVAWT)

Starting wind speed

High(≥3m/s)

Low(1m/s)

Wind conditions required

Require stable wind direction

Any wind direction

Encountered turbulence

Efficiency is reduce

Efficiency is not affected

Power stability

Changing by wind direction

Without any wind effect

Noise

Large (More than 45dB)

Low noise of less than 40dB  thank to maglev frictionless technology                        

Product appearance

Ordinary

Beautiful

Installation height

High (need to avoid the terrain turbulence)

Low (not influenced by  turbulence)

Installation location

Open area like suburb

Any locations

Generator material

Plastic or composite

metal

Structure strength

Poor (easy to broken)

High(double strengthen arm)

Resistance of wind speed

Poor(about 40 m/s)

High

 

2. Is it hard to install the wind turbine?

Re: System can be assembled in under an hour , without any welding; and ingle or multiple unit connections for greater energy generation. In addition, it is easy for connection with PV systems





Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Maintenance of electrical equipment, security measures to ensure that what
4, before each class must listen carefully to the previous report on the operation of the equipment, to understand the existing state of all equipment. 5, the maintenance of electric power equipment insulation must wear protective equipment, strict stop transmission system, stop transmission to a person responsible for the maintenance of switch control equipment, the switch to power and hang people work, no power "brand, and special care, strict implementation of the mine management regulations to stop electric. Only when the gas density is around 20 meters range is lower than 1%, only open power equipment, and use the same grade pencil test in cut off power supply, after the confirmation, discharge, and then can carry out comprehensive maintenance, maintenance end is correct, it can send electricity.
Q:What are the effects of frequency variation on power users and power systems?
As we all know, the asynchronous motor is widely used in industry. Its speed and output power are related to frequency. Changes in frequency, speed and power output of the motor is also changing, which seriously affected the quality of the product; modern industry, national defense and scientific research has been widely used in various electronic technology equipment, if the system frequency instability, affect the accuracy of these devices will be.
Q:What is the concentrator of the power set
There are two types of remote meter reading devices in electric power generation: one is low voltage set, called concentrator, the other is called terminal. The concentrator role is the number of meter data, first by the carrier or 485 communication way to collect the equipment, and then through the cable (optical fiber) or wireless network (cdma/gprs) transmitted to the main station.
Q:What are the relevant national standards for power equipment?
I don't know what to look for on the Internet
Q:The relationship between primary equipment and two equipment in power system
The electrical equipment of electric power system is divided into the primary equipment and the two equipment, and the primary equipment (also called the main equipment) is the main body of the power system
Q:What is the meaning of the power equipment in criminal law
The behavior of the power line that has been installed and has not yet been powered off shall be treated differently. If the stolen cut is not formally delivered to the power sector to use the line, should be handled in accordance with the theft case. If the actor knows the line has been delivered to the use of the power sector and steal cut wires, shall be designated as the crime of destruction of power equipment.
Q:Power transformer equipment bidding procurement are in what units
Power Grid Corp on the volume of business is greater, because their main business is to invest in the construction of power grids.There are also a small number of individual units, such as large projects and large enterprises.
Q:Ask the expert about the design of the power system diagram, 6kV side of the electrical equipment how to supply
220380 through 6KV.4kvIf you need to use 6kV from the 6KV bus with the line (equipped with power distribution switch), without the 6KV transformer, your system diagram is not equipped with the outlet is wrong
Q:In the city emergency security system, what are the relevant power equipment
The latest electric power emergency response and emergency plan for safety protection"Emergency treatment and safe latest power accident contingency plans to protect the implementation of manual" is based on the country's electricity production safety accident emergency system master, provides all levels of power supervision departments and the major power companies, power system, power grid to cope with major public emergencies working principle, organization system and operation mechanism, for guiding the competent departments and local governments at all levels in various industries and departments effectively deal with the power of public emergencies, protect public life and property safety, has an important role to reduce disaster losses.
Q:How to handle the qualification test, what kind of power equipment
(a) legal person qualification and perfect organization; (two) the registered capital and net assets of 60 million yuan; (three) the last 3 years to bear the following first items listed, third project and second sub items listed in any one project, and the project quality: above 1 thousand and 330 volts voltage substation 2 or 220 thousand volt substation 5; more than 2 thousand and 330 volt overhead lines 300 kilometers or 220 thousand volt overhead line of 500 kilometers; more than 3 thousand and 220 volt cable line 80 kilometers or 100 meters above the level crossing tower crossing project 1.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range