Lug Type Wafer Butterfly Valve DN40-DN1200

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
10000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Technical Date:

Size: DN40-DN1200

Nominal Pressure: PN10/PN16

Operation Temperature: -10°C~150°C

Suitable Medium: Water,Sewage,Seawater,Gas,Food,Oils,etc.

2. Standard

Design Standard: GB/T 12238-2008

Structural Length: GB/T 12221-2005

Top Flange dimensions: ISO5211

Face to face dimensions: GB9112,DIN2501,BS4504,ISO2084,ANSI125

Type of connection: Wafer Type

3. Feature:

 This valve is mainly composed of body, butterfly plate, valve shaft, seat and transmission devices. Simple and compact structure, small portable, convenient for transport, install and dismantle. 90 degrees of opening and closing, switch quickly, operating is small, light energy; Sealing performance is good, service life is long, can achieve zero leakages. Flow curve tending to straight line, excellent regulation performance.

4. Sealability:

The valve for rubber seal, closing butterfly plate and seat sealing performance is good, two-way sealed good performance and the torque is small. the friction is very small between butterfly plate and the seat seal. The valve shaft drive the butterfly plate, butterfly plate do 90 degrees rotation. Butterfly plate flexible for opening and closing, no card acerbity, beating phenomenon, small torque.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Pulmonary Valve Stenosis?
1761 - Pulmonary valvar or valvular stenosis is one of the more common forms of congenital heart malformations and it has been extensively studied since the original description of pulmonary valve stenosis by John Baptist Morgagni in 1761. 1888 - Tetralogy of Fallot, first characterized by Dr.Etienne Fallot in 1888, is present in about 3000 children born each year in the United States. It is a combination of four heart abnormalities. Dodrill and his colleagues employed it with success for the open correction of a stenotic pulmonary valve in October 1952.
Q:Butterfly valves are widely used in 2.0MPa below the pressure and temperature of not more than 200 degrees of various media, right?
3. kinds of butterfly valve:According to the connection mode: flange type, clip type.According to the material of sealing surface, soft seal and hard sealing.According to the structural form, butterfly valves can be divided into the following types:Plate typeInclined plate typeOffset plateLever type4. butterfly valve features:(1) the structure is simple and the shape is small. The utility model has the advantages of compact structure, short structural length, small size and light weight, and is suitable for large caliber valves.(2) the resistance of the fluid is small, and when the valve is fully opened, the valve seat passage has an effective circulation area, so the fluid resistance is smaller.(3) open and close, convenient and quick, good adjustment performance, butterfly plate rotation 90 degrees can be completed headstock. By changing the angle of rotation of the disc, the flow can be graded.(4) the opening and closing moment is smaller, because the butterfly plate on both sides of the rotating shaft is basically equal to the medium, and the opposite direction of the torque is generated, so that the opening and closing is more labor-saving.(5) low pressure sealing performance, sealing surface materials generally use rubber, plastic, sealing performance is good. Limited by the material of the sealing ring, the pressure and the temperature range of the butterfly valve are smaller. But the use of hard sealing butterfly valve pressure and temperature range has been greatly improved.
Q:Should I connect the butterfly valve before and after the pump? Or gate valve?
The best pump outlet valve, because the valve opening control accuracy, no movement. Valve structure is strong, adjusting performance better than butterfly valve. The pump outlet needs constant switching and adjustment, so the pump outlet valve is suitable for gate valve.Life water system valve, it is best to choose the gate valve, strong and reliable, cut off the system to grasp. But the cost is higher, occupying more space.Choose 1 or 1.6, there is no principle requirements, because the water supply pressure of life is generally between 0.25-0.5MPA, can meet the requirements. Only 1.6 is more durable and stronger, but the price is higher.
Q:Are all vacuum EGR valve the same?
HI i have question is all EGR valve work the same ? I Have an 86 Rx7 and when I test the EGR valve is doesn t hold pressure. So I m curios are they different from other vehicle due to is a rotary engine or due they all work the same. Thank You.
Q:Butterfly valve use
Butterfly valve (English: butterfly valve) refers to the closure of parts (valve or butterfly plate) for the disk, around the valve shaft to achieve rotation and closing of a valve, the main cut off on the pipe and throttling role. Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis of rotation, so as to achieve the purpose of opening or closing or regulation.
Q:Butterfly valve D71X-16 and D71X-16Q what is the difference?
D71X-16 can be ductile iron, stainless steel, carbon steel, and so onD71X-16Q can only be ductile ironIt's material that has special requirements. It seems like this
Q:Why do you need two butterfly valves in the water well?
Check the water gauge and check valve on both sides to facilitate the maintenance and replacement of water meter and check valve.
Q:Does the wet alarm valve group need to install the signal butterfly valve?
two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.
Q:How can you tell the difference between a functional valve murmur and a non-functioning valve murmur?
mechanical okorder.com/
Q:The difference between vertical and horizontal butterfly valves in municipal water supply
Vertical and horizontal only installation directions and installation methods are different. Functionally, there is no difference.The main difference between the two methods of installation is that:1. horizontal can effectively avoid the high temperature radiation above the pipe. The disadvantage is that it takes up a lot of space.The advantage of the 2. vertical is that the occupation space is smaller, and it is easy to install. If the pipeline is higher, it is not convenient for maintenance.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range