Low Price Electro Galvanized Wire Electric Galvanised Binding Wire

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t
Supply Capability:
2000 m.t/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Low Price Electro Galvanized Wire Electric Galvanised Binding Wire Description

Galvanized Iron Wire has the characteristics of thick zinc coating, good corrosion resistance, firm zinc coating, etc. 

Galvanized Iron Wire mainly used in construction, express way fencing, binding of flowers and wire mesh weaving. Galvanized iron wire according to manufacturing technique, it includes hot-dipped galvanized iron wire and electro galvanized iron wire. Mainly telecommunication equipment and materials, medical equipment and device, weaving of wire mesh, steel rope, and filtration mesh, high-pressure pipe, construction, arts and crafts.

2.Main Features of Galvanized Iron Wire

• Use widely

• Corrosion- resistant

• Durable 

• Practical use

• Beauty Surface

• Versatile

 

3. Galvanized Iron Wire Images

Low Price Electro Galvanized Wire Electric Galvanised Binding WireLow Price Electro Galvanized Wire Electric Galvanised Binding Wire

Low Price Electro Galvanized Wire Electric Galvanised Binding WireLow Price Electro Galvanized Wire Electric Galvanised Binding Wire

4.Galvanized Iron Wire Specification

 5.FAQ

We have organized several common questions for our clientsmay help you sincerely 

 

How about your products

One of the most biggest manufacturer & supplier of wires and wire meshis a large-scale professional Galvanized Iron Wire factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements. 

 

What is your Technical Information of Galvanized Wire?

1).Material: super carbon steel

2).Processing by drawing, hot-dip zinc-plating

3).Standard wire gauge from 8# to 24#

4).Thick zinc-coating layer

5).Super in corrosion resistance

6).Firm coating layer

7).Custom size available

 

How long can we receive the product after payment?

In the purchase of Galvanized Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Older ceiling fan wiring?
hook the green to green - the copper to the copper - the white to the white . now the black in the ceiling gets hooked to red and black in the fan
Q:Running wire from breaker box.?
That depends on your local and state codes and the conditions. Exposed? Concealed? All dry locations? Distance? I'd have to know way more to give you an accurate answer. Call an electrician to advise you.
Q:How can I identify the hot wire when I only have two black wires and no white wire in knob and tube wiring?
ok, a light switch is different then a outlet plug. the black wire is the hot wire and comes in to one side if the switch and goes out the other side. the switch just open the circuit to turn off the light or closes the circuit to turn it on.
Q:home thermostat wiring question.?
Well, unfortunately, this particular Hunter model isn't well-designed for operating heat pumps, which is what I'm assuming you've got, since you've got a W2 (aux heat) wire and and O/B (compressor reversal) wire. Still, you can sorta get it to work, but it might take some trial and error, when it comes to the O/B wire, as I'll explain in a minute. Here's the connections you should make: RH - 24VAC hot - connect to R wire RC - 24VAC cool - Jumper this to the RH connector G - Fan - connect to G wire Y - Compressor - connect to Y1 The O/B wire should connect to EITHER the Y/O or W/B, depending on your heat pump. If the reversing valve of the pump is supposed to operate when it heating mode, then you connect to the W/B terminal. If the reversing valve operates in cooling mode, you connect to the Y/O terminal. The other wires should be taped off with electrical tape and left disconnected. These wires are: W2 - auxiliary heat control - leave disconnected (your thermostat can't activate auxiliary heat) F - not sure what this is, to be honest; it might be for controlling a thermostat system check LED C - 24VAC common. Your thermostat doesn't need it.
Q:how to wire car alarm to 1996 dodge dakota?
1995-96 Dodge Dakota Alarm, Remote Starter, Keyless Entry Wiring Information Constant 12V+ Pink/Black Ignition Switch Harness Starter Yellow Ignition Switch Harness Ignition Dark Blue Ignition Switch Harness Ignition 2 Black Ignition Switch Harness Accessory Black/Orange Ignition Switch Harness Tach Gray Coil Neutral Safety Wire Brown/Yellow Driver's Side of Trans. Brake Switch White or White/Tan Brake Switch Trunk Pin n/a Parking Lights Black/Yellow Light Switch Head Lamp Light Green Light Switch Hood Pin n/a Door Trigger Yellow (-) Driver's Pin Switch Door Lock Orange/Purple Driver's Kick Panel Door Unlock Pink/Purple Reverse Polarity Horn Wire Dark Green/Red (-) Fuse Panel Windows Up LF=Light Blue, RF=Brown/White Windows Down LF=White, RF=Purple/White
Q:What's the use of the live wire,neautral wire and earth wire?
1. When it's working normally, Voltage would be present across Live and Neutral wire. Current would flow from Live to Neutral Wire. 2. When there is a fault, The voltage will be present in the live wire and as the circuit is not closed, No current would be flowing. 3. No it's not correct. But in some cases, the earth wire would be transmitted to the sub station where in its joined with the neutral. 4. Green 5. The Casing would be connected to earth. Hence the neutral is shorted with earth.
Q:Do you connect all wires when splicing a telephone wire?
each phone line uses a pair of wires (2 wires) these wires would normally be green/red or blue/white and solid blue for line 1 and if needed yellow/black or orange/white and solid orange for line 2... you did the first step in troubleshooting to know that the trouble resides inside your home... so when you call into your line does the phone ring busy (or go straight to voice mail) or does it just keep ringing.... if it rings busy (or straight to VM) then there is a short on the line... this is possibly a defective phone, a phone that is off the hook, or a bad jack or wire... if the phone just keeps ringing, then there is a broken wire somewhere...... since the old NID is no longer accessible, you may need to run a section of wire from the new NID to one of the existing jacks in your home to back feed the jacks... if you do this i recommend disconnecting the wire that is going from the new NID to the old NID, as if you reverse the polarity you may end up shorting out your line with the new wire...
Q:2005 ford taurus wiring diagram?
Hope this helps you out bro Car Radio Battery Constant 12v+ Wire: Green/Black Car Radio Accessory Switched 12v+ Wire: Black/Pink Car Radio Ground Wire: Black/Green Left Front Speaker Positive Wire (+): Orange/Green Left Front Speaker Negative Wire (-): Blue/White Right Front Speaker Positive Wire (+): Tan/Green Right Front Speaker Negative Wire (-): Green/Orange Left Rear Speaker Positive Wire (+): Gray/Blue Left Rear Speaker Negative Wire (-): Brown/Yellow Right Rear Speaker Positive Wire (+): Black/Violet Right Rear Speaker Negative Wire (-): Orange/Violet
Q:Car Stereo Wiring Help?
The part number for the correct wire harness for your vehicle is 70-2002 (made by Metra). You should be able to find it at Best Buy or Circuit City, or most car audio stores.
Q:2004 dodge durango radio wiring diagram?
If you havent already cut the wires then go to an audio store (best buy, local shop ect...) and buy a wiring harness. If you already cut the wires you NEED to test the wires with a test light and 9v battery and not rely on online diagrams because 90% of the time they are wrong. way to do it is find your positive, negative, and turn on wire with a test light. test every single wire with the test light to make sure there arent any live wires still left after you found your power wires. after you have done that to find the speakers take a 9 volt and hold one wire to the positive and touch every wire and listen for a speaker to make a scratching noise. when you hear the scratching noise then that means those two wires go to that speaker. if your totally lost then rewire the factory plug back on and then go get a wiring harness. theyre like 15-20 bucks and save you a whole lot of time and its a lot less mess to deal with.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range