Led Strip Light DC 12/24V / 5V SMD 5050 RGB 60 LEDS PER METER INDOOR IP20

Ref Price:
Loading Port:
Yantai
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
1000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

        1). Product Description:                                                                              

        1).  Products Name: Led flexible strip light,DC12V Led strip light, AC220V Led strip light, etc.

        2).  Input voltage (V): 85-265V AC

        3).  Output Voltage (V): DC12V or DC24V or AC220V, AC110V

        4).  SMD Type: SMD3528, SMD5050, SMD2835, SMD3014, SMD5630, SMD5730,SMD335,

        5).  Power Consumption Per Piece: 0.08w forSMD3528,  0.24w for SMD5050, etc. 0.10wfor SMD2835, or 0.20w for SMD2835,  0.5Wfor SMD5730, etc

        6).  LED Qty per meter: 30 LEDs/m, 60 LEDs/m, 96 LEDs/m,120 LEDs/m, 240 LEDs/m, others available.

        7).  Width: 4mm, 5mm, 6mm, 8mm, 10mm, 12mm widthPCB board,  White PCB Board or Yellow PCBBoard, Black PCB Board, etc.

        8).  Color Temperature (CCT): Warmwhite:2800-3500K, Natural white:4000-5000K, White:6000-7000K, Cool White:8000-15000K, other customized color available.

        9).  Emitting Color: Warm white, Natural white,White, Red, Green, Blue, Yellow, Pink, Purple, RGB.

        10).  Power per meter: 4.8W/M, 7.68W/M, 9.6W/M,3.6W/M, 7.2W/M, 14.4W/M, and others

        11).  Luminous Flux ( Lumens ): 4-5LM/pcs, 5-6LM/pc, 6-7LM/pcs,7-8LM/pcs, for SMD3528, and 11-13LM/pcs, 13-15LM/pcs, 16-18LM/pcs, 18-20LM/pcs,  for SMD5050, etc.

        12).  Waterproof Type: IP20, IP22, IP44, IP54,IP65, IP67, IP68,  Non-waterproof,  PU glue waterproof or Epoxy glue waterproof,  Better silicon waterproof,  Hollow tube waterproof,  PVC tube with silicon inside waterproof,  Phosphor Colourful Waterproof.

        13).  LED Chip Brand: Epistar, Brightlux, we do notuse Chinese Chips

        14).  Chip Pcs: 1 chip, 3 chips.

        15).  Certification: CE-EMC,CE-LVD, RoHS, CCC ,UL, FCC, RoHS, UL, ERP.

        16).  Drive Current Per Piece: 16mA, 18mA, 20mA,58mA, 60mA, 62mA, etc,

        17).  Power Factor: >90%

        18).  CRI (Ra>):80 Ra, others available.

        19).  Operating Temperature (): 40 to +50 degree Celsius

        20).  Life-span (Hour): 30000 ~  50000

        21).  Lamp Body Material: Copper

        22).  Place of Origin: Shenzhen, China (Mainland)

        23).  Brand Name: CMAX

        24).  Model Number: KU-3528-5050-60D,  many differenttype of models, please refer to our pricelist

        25).  Warranty: 1,2 and 3 years and 5 years

        26).  Beam Angle: 120 degree

        27).  Packaging Details: 1 meter/roll, 3meters/roll, 5meters/roll, 10 meters/roll, 40 meters/roll, etc,

        28).  Standard export package.

        29).  Light Decay: less than 3% after 1000 hoursconstant work

        30).  PCB Board Color: White or Yellow (Brown)

        31).  Layer thickness: single pcb board, double pcb board.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:LED soft light with color temperature 2400k what do you mean?
LED color temperature parameter is 2400K: color temperature generally press 3000K, warm white 4000K, white 6000K, cold white points.2400k is warm white, too.
Q:For LED lamp belt, under what circumstances with constant flow, under what circumstances with constant pressure, what are the principles?
If the constant pressure, at the beginning of the light, the current is not large, LED temperature rise to normal operating temperature, the current will increase rapidly, and quickly exceed the rated current, the life of LED will be greatly shortened. If the starting current is too low, the LED can not exert its high luminous power.
Q:Can the light belt be connected directly to the alternating current of 220 volts? Is it necessary to install a converter?
Can the light belt be connected directly to the 220 volt alternating current, depending on the specific type?.The lamp belt is divided into a high voltage lamp belt and a low voltage lamp belt, and the high-voltage lamp belt is provided with a conversion module, and the utility model can be directly connected with the 220V voltage. The low-voltage lamp belt is driven by a direct current and must be connected with the converted DC power supply.
Q:LED soft light belt?
Indoor installation: LED lights for indoor decoration, because of not having to undergo the installation is very simple so exposed to wind and rain. The ordinary LED lamp belt as an example, behind each LED lamp belt are affixed with self-adhesive 3M double-sided adhesive, the installation can be directly off the surface of the 3M double-sided adhesive stickers, and then the lamp strip is fixed on the installation place, hand press flat is good. As for some places need to corner or long, how? Very simple, LED light belt is a series of 3 LED as a series of parallel circuit structure, each 3 LED that can be cut alone. 7. controller connection: LED and RGB lights with marquee with the need to use the controller to achieve varying effect, while the control distance of each controller is not the same, in general, simple controller for 10 control distance to 15 meters, distance control remote controller is 15 to 20 meters, the longest can be controlled to a distance of 30 meters. If the length of the LED band is longer and the controller cannot control the length of the band, then the power amplifier will be used to tap it.
Q:Why can't the LED light band be broken from the fracture, but it can be light from the middle?
In order to ensure the brightness of the LEDs in the LED light band, the diode is usually connected in series. There are two possible reasons for the phenomenon:1) when one of the diodes is broken, the entire LED light band will not turn on;2] more diodes in series require a higher power supply voltage, and when the voltage is low, the entire led band will not turn on.
Q:How many watts are there in one meter, 70 bead, LED lamp?
LED lamp has many kinds of specifications, the rated voltage, current and power are different. For the lamp with beads are generally low voltage and small current, 70 meters of Pearl LED lights with about 3--5 watts, brightness equivalent to 40--100 watt incandescent bulbs.
Q:LED does the light carry electricity?
The one hundred and twenty beads also only a few W meters, total power at 115W, the general decoration is not so much the beads, we are manufacturers, so you ask this question is not professional. We are factory, companies do their own light, so we can be more stable in quality, the price has more advantages, including more about some parameters you can search on Baidu: CLS photoelectric Xiao Feng, there are some lights with the models, prices, power, installation effect map, etc.
Q:10 meters long, 24 volts, LED lights with 1 hours, how much power consumption?
Power is the measure of the transmission rate of energy. In a DC circuit, it is the product of the voltage V and the current A; it is much more complicated in the AC system. Whether they are high voltage or low voltage LED light belts, they convert AC to DC to work.
Q:Can the 220V LED belt be transferred to the 12V on board?
If you have a little electrical knowledge, the 220V lamp is divided into 20 sections, the 20 section light into parallel form, and remove the LED light input part of the rectifier part (circuit AC to DC), directly to the 12V DC voltage on it. In fact, LED 220V lights, is the 220V AC into 300V (the voltage is not certain, some have a buck, there is a full wave rectifier could reach 380V DC DC), added to the N series of LED lights, as long as you have this clear voltage on the line; because the working voltage of LED lamp the DC and DC voltage of single LED light value is generally between 2.7V~4V.
Q:How to install the LED lamp with the plug?
Check that the lead of the light port is approximately flush with the port. The distortion of the LED light band may cause the lead of the lamp band to slide relative to the outer plastic part. If the port in the light inside the wire out port, direct plug lamp with plug is easy to cause a short circuit, causing burning lamp with plug even with lights, encounter this kind of situation you will grow a trim to wire port. Be careful. If you cut too much, this meter will be cut off, so you must watch the line cut on the back of the lamp. Don't cut into the inside of the lamp bulb and the lamp with any loop. Be sure to pay attention to the wiring inside the light belt. After you cut the plug, you can light the lamp belt.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range