LED Lighting T 5 Integrated Light Having CE RoHS TUV ETL t5 Bracket Lamp

Ref Price:
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1000 set
Supply Capability:
100000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specification:


Material

Aluminium + PC cover

Body size

600mm

Light quantity

SMD2835/96Pcs

Power Installation

Power external in the tube

Work voltage

AC100-240V

Power consumption

10w

Power factor

>0.92

Work temperature

-20°C~+50°C

beam angle

120°

Color rendering

>80ra

Color temperature

2700-7200k

Luminous flux

950Lm

Light-to-Electric conversion yield

95%

Life span

50000hrs

Main Feature of LED Lighting T 5 Integrated Light Having CE RoHS TUV ETL t5 Bracket Lamp:

1.Magnetic&electronic ballast compatible

2.No need to remove starter or ballast.

3.No professional electrician needed 

4.Easy for installation

5.No labor cost,  maintenance free

6. instant start.

7. No UV, NO mecury, healthy for human body 

8.Power consumption:24w

9.Certificate:CE,RoHS,FCC,PSE,TUV,UL
10.Low power consumption
11.3 years warranty


Description:


1.Living room, bedroom,kitchen, washroom;


2.School, university, hospital,hotel;


3.Conference,meeting room, show room,showcase;


4.Commercial complexes;


5.Factory,plant,warehouse,office;


6.Supermarket,department store.

Images:

LED Lighting T 5 Integrated Light Having CE RoHS TUV ETL t5 Bracket LampFAQ:

 Q: Are you manufacturer of trading company?

A: Yes.




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The various specifications of LED fluorescent tubes
LED fluorescent tubes with the traditional fluorescent lamp in installation dimensions are the same caliber, length of 1500 px and 3000 px, 3750 px, the three kinds of the length of the LED fluorescent lamp power is 16 w and 10 w, 20 w, length is 600 mm, 900 mm and 1200 mm, 1500 mm, its power, respectively, 14 w, 9 w 18 w and 25 w, 20 w and traditional fluorescent lamp actual power consumption of about 53 w, 40 w fluorescent lamp traditional practical about 68 w power consumption; 9 w LED fluorescent lamp brightness than 18 w fluorescent lamp brightness to light, 18 w LED fluorescent lamp brightness than the traditional 40 w fluorescent lamp, LED fluorescent lamp brightness is especially more soft and make it easy for people to accept. The service life is between 30, 000 and 50, 000 hours of power supply as ac85v-260v (communication).
Q:The same thing is 5w, is this LED tube power or is this a fluorescent lamp?
In addition, under the condition of equal brightness LED lamp power is only 1/3 of the ordinary energy-saving lamps, so the same space, if use 20 w fluorescent energy-saving lamp tube, then switch to 8 wled lamp is bright enough. From this point of view, the electricity is greatly saved.
Q:The difference between the Ledt5 lamp and the temperature 3000k and 2700k
3000k lamp tube luminescence is white point, 2700k lamp tube illuminant red a dot.
Q:How long does the energy-saving daylight lamp tube change?
If a square originally needed a single one to reach the requirement, it now needs to be increased to three to achieve the original brightness. It's normally 3X36 = 108 watts per square root of 36 watts. It turns out that electricity consumption is only 0.036 degrees per hour and now it is 0.108 degrees to achieve the same brightness. The more you open it, the more energy you will consume. Besides, this is without causing damage to the case, the general tubes to use fixed number of year will gradually damaged, bad time change time will be more trouble, so as to compare and calculate a one-time change.
Q:Why don't leds need a rectifier
LED is a dc device, and the driver must be different. If you do not remove the rectifier, you may not install the LED lamp.
Q:What is the connection of the LEDT5 lamp tube, the main line is how to connect, only to the end
You look at the instruction manual, this kind of lamp does not lead to ground line, see if can adjust brightness? Or the color palette? But such a small lamp is almost impossible to implement, or the yellow line is simply suspended, and the usual ground line is the outer shell of a metal shell
Q:What's the difference between an LED fluorescent lamp and a regular fluorescent lamp?
LED fluorescent lamp does not blink, save electricity, long life, do not pollute the environment.
Q:Fluorescent lamp fire line zero connection
If you want to break the wire, the short line will flash. Because the wire is stronger than the zero line in a single case
Q:LED T5 T8 and normal fluorescent lamps with no ballast
A 16W LED fluorescent lamp, equivalent to 40W of ordinary fluorescent lights!
Q:Is there any LED fluorescent lamp that can be used for more than five years?
Currently, there is no such thing as civilian use for 3-5 years, but the commercial is still below that level.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range