LED Lighting Integrated Tube5 CE RoHS TUV ETL t5 Bracket Lamp

Ref Price:
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1000 set
Supply Capability:
100000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

LED Lighting Integrated Tube5 CE RoHS TUV ETL t5 Bracket Lamp Specification:


Material

Aluminium + PC cover

Body size

600mm

Light quantity

SMD2835/96Pcs

Power Installation

Power external in the tube

Work voltage

AC100-240V

Power consumption

10w

Power factor

>0.92

Work temperature

-20°C~+50°C

beam angle

120°

Color rendering

>80ra

Color temperature

2700-7200k

Luminous flux

950Lm

Light-to-Electric conversion yield

95%

Life span

50000hrs

Main Feature of LED Lighting Integrated Tube5 CE RoHS TUV ETL t5 Bracket Lamp:

1.Magnetic&electronic ballast compatible

2.No need to remove starter or ballast.

3.No professional electrician needed 

4.Easy for installation

5.No labor cost,  maintenance free

6. instant start.

7. No UV, NO mecury, healthy for human body 

8.Power consumption:24w

9.Certificate:CE,RoHS,FCC,PSE,TUV,UL
10.Low power consumption
11.3 years warranty
10.No fluorescent flickering
11.No RF interference, no buzzing noise.
12.No hazard of mercury or lead entering the environment
13.Easy in stallation
14.No dangerous of glass broken

 

LED Lighting Integrated Tube5 CE RoHS TUV ETL t5 Bracket Lamp Description:


1.Living room, bedroom,kitchen, washroom;


2.School, university, hospital,hotel;


3.Conference,meeting room, show room,showcase;


4.Commercial complexes;


5.Factory,plant,warehouse,office;


6.Supermarket,department store.

Images:

LED Lighting Integrated Tube5 CE RoHS TUV ETL t5 Bracket LampFAQ:

What certificates do you have for your products?

ISO



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the details of the whole process of the LED lamp?
Hello, we are the certification testing agency, the LED light tube is simple, send samples, provide product data, test, report and certificate, thank you!
Q:What's the matter with the light bulbs?
It's the regenerator problem, or the regenerator block.The wiring didn't catch up.
Q:What does philips mean by TLD36w / 54-765
Yeah, I did it for you, I think it's the bottom, Let's see if it is ~ TLD ~ T8 Dailyght 160-240v (model) 36 ~ 36 w.I hope my answer will work for you.
Q:What happens when daylight lights go on
Fluorescent lamp is made of daylight lamp, ballast, consisting of the starter, under normal circumstances fluorescent lamp in the process of start, due to the action of bimetallic strip within the starter, make a sound, "da" start fluorescent work light. The sound is usually the "buzz..." when it's on. Current sound, the sound is due to the ballast assembly is not tight, leaching asphalt technology is bad internal noise caused by loose of silicon steel sheet, and some small factory's products to reduce costs is omitted asphalt link, appear easily in the use of sound.
Q: The title What is the color temperature of the leds?
There are two types of traditional daylight lighting, the warm color of 3000K and the positive white 6500K, and the leds are almost as close as the two colors.
Q:Can fluorescent tube T5 and LED T5 be connected in tandem?
Where did you see the electrical series, the series is not going to work. You're talking about parallel, too.
Q:The same thing is 5w, is this LED tube power or is this a fluorescent lamp?
Power consumption is the same, but brightness is different.The fluorescent lamp is good for people's eyes, LED saves electricity, oneself choose.
Q:How do you measure the flux of the LED fluorescent tube
In theory, it's measurable, and it's actually hard to set up. There are two ways of measuring flux, essentially the same thing 1: the integrating ball is measured by your illuminometer 2: set up the field aperture + your illuminometer + space station to measure by the 4PI () stereo Angle integral. The last time you said you have integral ball and light meter I suggest the first way is feasible. In addition you put not fluorescent lamp it doesn't matter, can be measured in area of block of luminous flux, and finally take the area integral. The results must be less than professional distribution photometer to measure, the standard but the data still have rigorous theory and process support.
Q:The ambient humidity of the LED daylight lamp is in the range
In a daily environment, this product doesn't have to worry about humidity,
Q:What's the difference between a single input and a double-end input?
Like our products, single side used on special occasions, be flat installation place, double side is directly used in the traditional ordinary lamp, so change the LED fluorescent lamp is very convenient.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range