Product Description:

Range summary


The Acme.F range front access valve regulated lead acid batteries is designed with real front access structure. The state-of the-art internal and external design ensures Acme.F the high reliability and makes the installation squite simple and safe when placed on a standard relay rack tray or in a closed cabinet.
 Acme.F range VRLA battery is designed with high energy density and suitable for 19". 23" rack or cabinet.
                                    

Acme.F also offers options of top connection and side of monoblocs connection.

The terminal protector for Acme.F batteries are designed with special probe hole allowing safe and easier voltage testing and suitable for all connection means.

The specially centralized venting system ensures the small gas be vented our of the closed cabinet
                                     

The prmium Acme.F batteries are ensured  the quality with NARADA's QA system according to the ISO90001 and ISO14001 standard.









Technical features

  • Real front-access terminal connections for fast and easy installation and maintenance

  • Easy on easy off multi-purpose design ternimal protector

  • Suitable for 19", 23" racking or cabinet

  • Proven excellent special lead-tin-calcium formula alloy for grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Flame retardant ABS material container and cover compliant with UL94 V-0

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full  float service at 68oF(20oC)

     

 

Type:

  12NDF300

Voltage:

  12V

Nominal Capacity:

  100Ah(C10)  100Ah(10 hours rate:)

Length:

  390mm

Width:

  105mm

Height:

  287mm

Height   with termial:

  287mm

Weight:

  33Kg

Compliant standards
Designed to be compliant with:

  • IEC 60896-2

  • BS 6290 Part 4

  • Telcordia SR-4228

  • EUROBAT GUIDE

  • UL

  • Manufactured under system ISO9001 & ISO14100 by NARADA

Battery installation compliant with:

EN 50272-2 or local equivalents

Main applications

  • Telecom standby and cyclical applications

  • UPS

  • Power system

Products characteristics:

  • Recommended float charge voltage for 12V battery: 2.25Vpc at 77oF(25oC)

  • Self discharge rate: < 2% pre month at 77oF(25oC)

  • Design life: more than 12 years at 68oF(20oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Valve regulated system, no water addition needed

FAQ 

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.


Are lead acid batteries recyclable?

Lead acid batteries are 100% recyclable. Lead is the most recycled metal in the world today. The plastic containers and covers of old batteries are neutralized, reground and used in the manufacture of new battery cases. The electrolyte can be processed for recycled waste water uses. In some cases, the electrolyte is cleaned and reprocessed and sold as battery grade electrolyte. In other instances, the sulfate content is removed as Ammonia Sulfate and used in fertilizers. The separators are often used as a fuel source for the recycling process.


What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q:How to deal with waste batteries?
Laboratory recycling method: ordinary dry battery is cylindrical, the outer cylinder made of zinc, the zinc cylinder is the battery negative; tube central carbon rod for the positive; tube for the manganese dioxide, ammonium chloride and chlorination Zinc.
Q:What is the meaning of the battery above 12v65Ah?
12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
Q:The role of the battery?
Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q:How does the battery increase the voltage?
The so-called battery is the storage of chemical energy, if necessary, the release of electrical energy of an electrical chemical equipment.
Q:What battery does the van use?
The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
Q:How to determine the battery is good or bad?
Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:Lead-acid battery how to maintain?
When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range