Product Description:

Range summary

The Acme.F range front access valve regulated lead acid batteries is designed with real front access structure. The state-of the-art internal and external design ensures Acme.F the high reliability and makes the installation squite simple and safe when placed on a standard relay rack tray or in a closed cabinet.
 Acme.F range VRLA battery is designed with high energy density and suitable for 19". 23" rack or cabinet.

Acme.F also offers options of top connection and side of monoblocs connection.

The terminal protector for Acme.F batteries are designed with special probe hole allowing safe and easier voltage testing and suitable for all connection means.

The specially centralized venting system ensures the small gas be vented our of the closed cabinet

The prmium Acme.F batteries are ensured  the quality with NARADA's QA system according to the ISO90001 and ISO14001 standard.

Technical features

  • Real front-access terminal connections for fast and easy installation and maintenance

  • Easy on easy off multi-purpose design ternimal protector

  • Suitable for 19", 23" racking or cabinet

  • Proven excellent special lead-tin-calcium formula alloy for grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Flame retardant ABS material container and cover compliant with UL94 V-0

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full  float service at 68oF(20oC)






Nominal Capacity:

  165Ah(C10)  165Ah(10 hours rate:)







Height   with termial:




Compliant standards
Designed to be compliant with:

  • IEC 60896-2

  • BS 6290 Part 4

  • Telcordia SR-4228


  • UL

  • Manufactured under system ISO9001 & ISO14100 by NARADA

Battery installation compliant with:

EN 50272-2 or local equivalents

Main applications

  • Telecom standby and cyclical applications

  • UPS

  • Power system

Products characteristics:

  • Recommended float charge voltage for 12V battery: 2.25Vpc at 77oF(25oC)

  • Self discharge rate: < 2% pre month at 77oF(25oC)

  • Design life: more than 12 years at 68oF(20oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Valve regulated system, no water addition needed


How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Are lead acid batteries recyclable?

Lead acid batteries are 100% recyclable. Lead is the most recycled metal in the world today. The plastic containers and covers of old batteries are neutralized, reground and used in the manufacture of new battery cases. The electrolyte can be processed for recycled waste water uses. In some cases, the electrolyte is cleaned and reprocessed and sold as battery grade electrolyte. In other instances, the sulfate content is removed as Ammonia Sulfate and used in fertilizers. The separators are often used as a fuel source for the recycling process.

What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to deal with waste batteries?
The rest of the various types of waste batteries are generally shipped to a special toxic, hazardous landfill, but this approach not only cost too much but also cause waste, because there are many useful raw materials available.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery using lead-calcium alloy grille, the amount of water generated when charging less water evaporation is low, with the shell with a sealed structure, the release of sulfuric acid gas is also very little, so with the above advantages.
Q:What battery does the van use?
The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
Q:What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
Q:80ah how much battery storage capacity?
The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
Q:What are the technical parameters of the battery?
Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
Q:How is the capacity of the battery defined?
General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
Q:Maintenance-free battery how to detect it?
Keep the battery surface clean. If the discovery of solid oxide on the pole, it should be timely with hot water pouring, to be removed, so as not to affect the pole and the terminal between the continuity. After cleaning up, wipe the battery surface, in the pole and the terminal cast on the butter to ensure that the pole is not oxidized.
Q:What kind of battery is divided into?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water. It also has a shock, high temperature, small size, self-discharge characteristics of the general life is generally ordinary Twice the battery. There are two kinds of maintenance-free batteries on the market.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range