Range summary


The Acme.F range front access valve regulated lead acid batteries is designed with real front access structure. The state-of the-art internal and external design ensures Acme.F the high reliability and makes the installation squite simple and safe when placed on a standard relay rack tray or in a closed cabinet.
 Acme.F range VRLA battery is designed with high energy density and suitable for 19". 23" rack or cabinet.
                                    

Acme.F also offers options of top connection and side of monoblocs connection.

The terminal protector for Acme.F batteries are designed with special probe hole allowing safe and easier voltage testing and suitable for all connection means.

The specially centralized venting system ensures the small gas be vented our of the closed cabinet
                                     

The prmium Acme.F batteries are ensured  the quality with NARADA's QA system according to the ISO90001 and ISO14001 standard.









Technical features

  • Real front-access terminal connections for fast and easy installation and maintenance

  • Easy on easy off multi-purpose design ternimal protector

  • Suitable for 19", 23" racking or cabinet

  • Proven excellent special lead-tin-calcium formula alloy for grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Flame retardant ABS material container and cover compliant with UL94 V-0

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full  float service at 68oF(20oC)

 

Type:

  12NDF165

Voltage:

  12V

Nominal Capacity:

  165Ah(C10)  165Ah(10 hours rate:)

Length:

  558mm

Width:

  125mm

Height:

  270mm

Height   with termial:

  270mm

Weight:

  52.5Kg

Compliant standards
Designed to be compliant with:

  • IEC 60896-2

  • BS 6290 Part 4

  • Telcordia SR-4228

  • EUROBAT GUIDE

  • UL

  • Manufactured under system ISO9001 & ISO14100 by NARADA

Battery installation compliant with:

EN 50272-2 or local equivalents

Main applications

  • Telecom standby and cyclical applications

  • UPS

  • Power system

Products characteristics:

  • Recommended float charge voltage for 12V battery: 2.25Vpc at 77oF(25oC)

  • Self discharge rate: < 2% pre month at 77oF(25oC)

  • Design life: more than 12 years at 68oF(20oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Valve regulated system, no water addition needed

FAQ 

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.


Are lead acid batteries recyclable?

Lead acid batteries are 100% recyclable. Lead is the most recycled metal in the world today. The plastic containers and covers of old batteries are neutralized, reground and used in the manufacture of new battery cases. The electrolyte can be processed for recycled waste water uses. In some cases, the electrolyte is cleaned and reprocessed and sold as battery grade electrolyte. In other instances, the sulfate content is removed as Ammonia Sulfate and used in fertilizers. The separators are often used as a fuel source for the recycling process.


What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q:How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q:What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:How is the capacity of the battery defined?
The capacity of the battery unit is AH (safety) is the product of current and time.
Q:What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q:What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
Q:What kind of battery is divided into?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water. It also has a shock, high temperature, small size, self-discharge characteristics of the general life is generally ordinary Twice the battery. There are two kinds of maintenance-free batteries on the market.
Q:How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range