Kerosene Heaters with Double Tank System
- Ref Price:
- $1.00 - 99.00 / carton
- Loading Port:
- FUZHOU
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1 Twenty-Foot carton carton
- Supply Capability:
- 50000 cartons per Month carton/month
- OKorder Service Pledge
- Quality Product
- Order Online Tracking
- Timely Delivery
- OKorder Financial Service
- Credit Rating
- Credit Services
- Credit Purchasing
Product Description
KEROSENE HEATER SPECIFICATION
ITEM NO. | DESCRITPION | |
KSP-229 | Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 32*32*46CM | ||
N.W/G.W: 4.0/4.8KG | ||
Tank Capacity: 4.5L | ||
Fuel Consumption(L/HR):0.24-0.28L | ||
Heater output: 7800-8900(BTU/HR) | ||
Continues Heating Duration:17-18hr | ||
Container Capacity: about 595pcs/20FT, 1434pcs/40HQ | ||
Chimney Type:Metal | ||
Tank System:Double | ||
Ignition type:Match | ||
Heating area: 12-15 Square meters(for reference) | ||
Other details:Adjustable thermostat | ||
KSP-231C | Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 32.5*32.5*47.5 CM | ||
N.W/G.W: 4.8/5.6kgs | ||
Tank Capacity: 5.3L | ||
Fuel Consumption:0.24-0.28L/Hr | ||
Heater Output: 7800-8900BTU/Hr | ||
Continues Heating Duration:17-18hr | ||
Container Capacity: about 587pcs/20FT, 1344pcs/40HQ | ||
Chimney Type:Metal | ||
Tank System:Triple | ||
Ignition Type: Match | ||
Heating area: 12-15 Square meters (for reference) | ||
Other details:Adjustable thermostat | ||
KSP-2310 | Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 32.5*32.5*47.5 CM | ||
N.W/G.W: 4.8/5.6kgs | ||
Tank Capacity: 5.3L | ||
Fuel Consumption:0.24-0.28L/Hr | ||
Heater Output: 7800-8900BTU/Hr | ||
Continues Heating Duration:17-18hr | ||
Container Capacity: about 587pcs/20FT, 1344pcs/40HQ | ||
Chimney Type:Metal | ||
Tank System:Triple | ||
Ignition Type: Match | ||
Heating area: 12-15 Square meters (for reference) | ||
Other details:Adjustable thermostat,Tip-over protection | ||
| Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 32.5*32.5*46.0CM | ||
N.W/G.W: 4.9/5.6kgs | ||
Tank Capacity: 5.3L | ||
Fuel Consumption:0.24-0.28L/Hr | ||
Heater Output: 7800-8900BTU/Hr | ||
Continues Heating Duration:17-18hr | ||
Container Capacity: about 595pcs/20FT, 1434pcs/40HQ | ||
Chimney Type:Glass | ||
Tank System:Triple | ||
Ignition Type: Match | ||
Heating area: 12-15 Square meters (for reference) | ||
Other details:Adjustable thermostat | ||
| Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement:32*32*44CM | ||
N.W/G.W:4.7/5.4KG | ||
Tank Capacity: 2.5 L | ||
Fuel Consumption:0.22-0.27L | ||
Heater Output: 7800-9800BTU/Hr | ||
Continues Heating Duration:10-12hr | ||
Container Capacity: about 595pcs/20FT, 1511pcs/40HQ | ||
Chimney Type:Glass | ||
Tank System:Triple | ||
Ignition Type: Match | ||
Heating area: 12-16 Square meters (for reference) | ||
Other details:Adjustable thermostat,Tip-over protection | ||
S-85A1 | Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 42*31*51.5CM | ||
N.W/G.W: 6.1/7.3kgs | ||
Tank Capacity: 4.2L | ||
Fuel Consumption:0.23-0.26L/Hr | ||
Heater Output: 7000-8300BTU/Hr | ||
Continues Heating Duration:8-10hr | ||
Container Capacity: about 400pcs/20FT, 1020pcs/40HQ | ||
Chimney Type:Glass | ||
Tank System:Double | ||
Ignition Type: Electronic | ||
Heating area: 12-14 Square meters (for reference) | ||
Other details:Adjustable thermostat,Tip-over protection | ||
WKH-3450 | Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 66.0*32.5*51.50CM | ||
N.W/G.W: 9.7/11kgs | ||
Tank Capacity: 3.8L | ||
Fuel Consumption: maximum 0.36L/Hr | ||
Heater Output: 12,500BTU/Hr | ||
Continues Heating Duration:9-14hr | ||
Container Capacity: about 235pcs/20FT, 625pcs/40FT | ||
Chimney Type:Glass | ||
Tank System:Removable | ||
Ignition Type: Electronic | ||
Heating area: 21-25 Square meters (for reference) | ||
Other details:Adjustable thermostat,Tip-over protection | ||
| Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 46*46*60.0CM | ||
N.W/G.W: 10.5/12.0kgs | ||
Tank Capacity: 7.5L | ||
Fuel Consumption:0.53L/Hr | ||
Heater Output: 22300BTU/Hr | ||
Continues Heating Duration:9-12hr | ||
Container Capacity: about 224pcs/20FT, 500pcs/40HQ | ||
Chimney Type:Glass | ||
Tank System:Single | ||
Ignition Type: Electronic | ||
Heating area: 29 Square meters (for reference) | ||
Other details:Adjustable thermostat,Tip-over protection | ||
Bitmap
| Kerosene Heater | |
Packing: 1pc/ctn | ||
Measurement: 65.0*37.0*51.0CM | ||
N.W/G.W: 9.0/10.2kgs | ||
Tank Capacity: 5.0L | ||
Fuel Consumption:0.223-0.279L/Hr | ||
Heater Output: 7800-9800BTU/Hr | ||
Continues Heating Duration:18-22hr | ||
Container Capacity: about 235pcs/20FT, 540pcs/40HQ | ||
Chimney Type:Glass | ||
Tank System:Removable | ||
Ignition Type: Electronic | ||
Heating area :21 Square meters (for reference) | ||
Other details:Adjustable thermostat,Tip-over protection | ||
OC-3000 | Gas Heater | |
Packing: 1pc/ctn | ||
Measurement: 29*29*38CM | ||
N.W/G.W: 3.2/3.8 kgs | ||
Fuel Consumption:80-150g | ||
Heater Output: 4000-6000BTU/Hr | ||
Container Capacity: about 930pcs/20FT, 2120pcs/40HQ | ||
Chimney Type:Metal | ||
Ignition Type:Piezoelectric ceramic ignitor | ||
Heating area :8-10 Square meters (for reference) | ||
Other details:Adjustable thermostat |
Okorder services for you
Ver.1
1. We will reply you in detail within 24 hours
2. We own well-trained and professional sales and after- sale services who can speak fluent English.
3. We offer OEM services and can print your own logo on products.
4. We have strong ability to do ODM projects.
Ver.2
1.7*24 hours Hotline & Email Service
2. Your inquiry related to our products or prices will be replied in 24hrs.
3. Well-trained and experienced staffs to answer all your enquires in fluent English
4. OEM&ODM, any your customized demand we can help you to design and put into product.
5. Distributor ship are offered for your unique design and some our current models
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Similar products
New products
Hot products
Hot Searches
Related keywords
You Might Also Like