JET Self-priming Centrifugal Water Pumps

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Production Introduction:
JET series pumps have the advtanges and characteristic of self-priming pumps and centrifugal pumps. Water jet elements realize self-priming function.Pumps by the optimized design, have the advantages of bigger suction, high head, smooth operation, and reliable performance, which is the ideal tool for agriculture, and household, etc

2. Application:
This series pump is a new type of ideal economical household pump, and widely used in pumping water from well, increasing water pressure, garden irrigation, water supply for vegetable green houses, industrial mining enterprises and aquatic breeding fields etc.
3. Work Conditions:
The pump can work properly and continuously under following op¬erational conditions:
1.Medium is not corrosive. Sand contents should be max.0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40℃and PH should be6.5-8.5.
3.Power frequency should be 50Hz,single phase voltage 220V, and voltage fluctuation should be 0.9-1.1 times than the rated.

4. FAQ

1)  Are CNBM pumps available in DIY stores?

Yes, currently, we’re available for DIY stores all over the world.

2)  Where do I have to send pumps for service?

You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China.

3) Are your pumps acid-proofed?

To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid.

JET Self-priming Centrifugal Water Pumps

JET Self-priming Centrifugal Water Pumps


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same
Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Q:Why can the centrifugal pump hold down the pressure?
The pump before starting to pump shell and the water pipe filled with water, and then start the motor, the pump shaft to drive the impeller and water do high-speed rotation, centrifugal water movement, was thrown to the outer edge of the impeller, the pressure water pipeline flow through the volute pump into the pump shell.
Q:What is the liquid pump? What are their categories? What are their strengths and weaknesses?
The air driven liquid pump adopts compressed air driving method, and has the following advantages:The pressure can be adjusted by manual pressure control valve or air control valveIt is driven by air and is especially suitable for explosion protection applicationsAble to achieve pre-set final pressureAutomatic pressure relief by pumpLong term conservation without consuming energyWhen holding pressure, medium will not overheatThe utility model has the advantages of convenient installation and low maintenance cost, and only needs to connect the gas source, the inlet pipeline and the pressure pipelineReliable operation, low maintenance cost and little noise at the time of operation
Q:Must the water pump in the tank be all soaked in water?
Usually you have to soak it all in the water. If you don't want to put it in the water, you can buy an amphibious pump. At most, you can expose it
Q:What is the series of pumps? What's the difference between a unipolar and a multistage?
A single-stage pump is a pump with only one impeller. 2, a multistage pump is a pump with two or more impellers. The multistage pump can increase the pressure and lift the head higher. Level 1 means a booster impeller.
Q:What are the characteristics of a pipe shield pump?
Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Q:Centrifugal pump flow, why can be adjusted through the outlet valve?
Reciprocating pump is a positive displacement pump, the volume change of flow is the unit of time, constant flow speed constant, can not rely on increased resistance to change the flow resistance increase is only leaked, only small changes in flow.
Q:Metering pumps related matters
Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.
Q:What is the function of the heating pump system for the water pump design?
As the feed water temperature is higher, in the case of non warm pump start, will make the pump body is subject to greater thermal impact; in addition, the flow components with the pump contact heating fast, not contact with water directly heating slowly. This expansion due to uneven speed, it will inevitably produce thermal stress, deformation of the pump body, sealing surface, the joint surface is lax and leaking phenomenon. Therefore, the warm water pump system is designed for the water pump.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range