Product Description:


ISW series horizontal pipeline centrifugal pump
1.widely use
3.comptitive products and price

ISW series horizontal pipeline centrifugal pump

Product Description

1, smooth operation: absolute concentricity of pump shaft excellent static and dynamic balance of impeller ensure stable operation, no vibration.
2, watertight: hard alloy seal with different materials to ensure the transportation of different media are no leakage.
3, low noise: two low noise bearing of the water pump, smooth operation, in addition to the motor faint sound, the basic no noise.
4, low failure rate, structure is simple and reasonable, the key part adopts the international first-class quality form a complete set, the trouble-free working time greatly improve.
5, easy maintenance: replace seal and bearing, simple convenient.
6, more space-effective: the outlet is available to the left, right, up three direction, easy for pipeline layout and installation, save a space.
7, ISW horizontal fresh water pump for conveying water and physical and chemical properties of YuQingShui similar other liquid and suitable for industrial and urban water supply, pressurized water supply in high-rise constructions, garden sprinkler irrigation, fire booster, distant distance transportation, hvac refrigeration cycle, such as the bathroom, cold and hot water circulation pressurization and equipment accessories, using temperature T acuities were 80 °C.
8, ISWR horizontal hot water pump are widely used in metallurgy, chemical industry, textile, papermaking, and hotels etc boiler hot water booster cycle transport and urban heating system, ISWR type using temperature T 120 °C or less.
9, ISWH horizontal chemical pump, for delivery not containing solid particles, and viscosity similar to corrosive liquid water, used in petroleum, chemical, metallurgy, electric power, papermaking, food, pharmacy and synthetic fibre and other departments, the use of temperature from °C ~ + 120 °C.
10, ISWB horizontal pipeline oil pump for transport gasoline, kerosene, diesel oil and other oil products or flammable, late detonation liquid, by conveying medium temperature of 20 °C ~ + - 120 °C

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Have to know the ratio, pneumatic pump, if high pressure, you can have 2:1,3:1
Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:What is a vacuum pump for?
In fact, the vacuum pump and high Swiss fan, high Swiss high-pressure blower, high Rui high-pressure pump principle is almost the same
Q:What are the characteristics of a vertical multistage centrifugal pump?
A liquid that is primarily diluted, clean, non corrosive, explosive, or similar to water but contains no solid particles or fibers. Because of its high flow and large lift, it is widely used in fire fighting, water supply and air conditioning unit cooling water transportation in high-rise buildings.
Q:Roots pump and dry pumpRecently, the work involved in the vacuum pump, do not understand this, is a ads602 vacuum pump
The front stage pump to a certain pressure to start the roots pump, roots pump has advantages of is at the entrance of low pressure gas pumping speed is high, popular point is in high vacuum pumping speed is still relatively large. With the former pump can achieve different limit the vacuum is different.
Q:How can I buy a pump?
Selection principle of pump:1, so that the selected pump type and performance parameters meet the unit flow, lift, pressure, temperature and other requirements, the most important thing is to determine the voltage, the maximum lift, and when the head high reached much traffic.
Q:What are the general water pump failure, how to repair?
Troubleshooting of water pumpFirst, the water pump does not cause water analysisThere is air in the inlet pipe and pump body(1) before the water pump is started, the water is not filled enough. Sometimes it seems that the water has been discharged from the vent hole, but the pump shaft is not rotated. The air is completely discharged, resulting in a small amount of air remaining in the inlet pipe or pump body.
Q:Does the reservoir water heater press the booster pump (high marks)?
60 liters of water storage should be able to drive two bathrooms at the same time bath! Water storage water heater generally does not need booster pump, as long as there is a little pressure, the water heater is filled with water, as long as the tap water can do. You can turn off the hot water valve and see only the amount of water in the cold water. If hot water is much smaller than cold water, it is the reason for the heater. Can you check the water mixer is normal, the one-way valve is installed in reverse.
Q:What are the problems that should be paid attention to when using vacuum pumps?
(8) in the process of running the pump, the bearing temperature shall not exceed the ambient temperature 35C, and the maximum temperature shall not exceed 80C.(9) if the abnormal sound of the vacuum pump is found, the reason should be stopped immediately.(10) vacuum pump to stop using, first shut down valve, pressure gauge, and then stop the motor. (11) vacuum pump in the first month of work, 100 hours after the replacement of lubricating oil, oil every 500 hours after the change.(12) adjust packing gland regularly to ensure the normal condition of drip in packing room. (13) regular inspection of shaft sleeve wear, larger wear should be replaced in good time.
Q:What's the pump? Where can I use it?
Working principleIt transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell. In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range