Iron Butterfly Valve DN80

Ref Price:
Loading Port:
China Main Port
Payment Terms:
Min Order Qty:
Supply Capability:

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Technical Date:

Size: DN40-DN1200

Nominal Pressure: PN10/PN16

Operation Temperature: -10°C~150°C

Suitable Medium: Water,Sewage,Seawater,Gas,Food,Oils,etc.

2. Standard

Design Standard: GB/T 12238-2008

Structural Length: GB/T 12221-2005

Top Flange dimensions: ISO5211

Face to face dimensions: GB9112,DIN2501,BS4504,ISO2084,ANSI125

Type of connection: Wafer Type

3. Feature:

 This valve is mainly composed of body, butterfly plate, valve shaft, seat and transmission devices. Simple and compact structure, small portable, convenient for transport, install and dismantle. 90 degrees of opening and closing, switch quickly, operating is small, light energy; Sealing performance is good, service life is long, can achieve zero leakages. Flow curve tending to straight line, excellent regulation performance.

4. Sealability:

The valve for rubber seal, closing butterfly plate and seat sealing performance is good, two-way sealed good performance and the torque is small. the friction is very small between butterfly plate and the seat seal. The valve shaft drive the butterfly plate, butterfly plate do 90 degrees rotation. Butterfly plate flexible for opening and closing, no card acerbity, beating phenomenon, small torque.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between the installation and function of a butterfly valve and butterfly valve?
Therefore, the fully open position of the valve is determined by the position of the gate. Some gate valve, stem nut is located on the gate, the handwheel rotates to drive the stem to rotate, and make the gate lift, this kind of valve is called rotary bar gate valve, or call dark rod gate valve. The type of gate width, sealing surface configuration can be divided into wedge gate valve and parallel gate valve, wedge gate type valve can be divided into: single gate type, dual gate plate and the flexible gate type; parallel gate type valve can be divided into single and dual gate gate plate. According to the thread position of the valve stem, can be divided into two kinds of open rod gate valve and dark rod gate valve. Valve installation and maintenance should pay attention to the following: hand wheel, handle and transmission mechanism are not allowed for lifting, and is strictly prohibited. Double gate valve should be installed vertically, that is, the valve stem is in a vertical position, and the handwheel is at the top. The gate valve with bypass valve shall be opened before opening to balance the pressure difference between inlet and outlet and reduce the opening force. The gate valve with drive mechanism is installed according to the instruction of the product instruction. If the valve is constantly switched on, lubricate it at least once a month. The valve has the advantages of small fluid resistance, the sealing surface by the erosion of small and medium Chong brush. Opening and closing is more labor-saving. Medium flow direction is unrestricted, no disturbance, no pressure reduction. The utility model has the advantages of simple shape, short structural length, good manufacturing technique and wide application range. Valve faults between the sealing surface can lead to erosion and abrasion, maintenance more difficult. Larger size, open need a certain space, long opening and closing time. Complex structure.
Q:What's the size of the signal butterfly valve sleeve?
The output signal is stable and reliable for a long time. The valve has an electric node, which is drawn out to the control center by signal line, and the signal line voltage is 12V. In fact, the valve is open and closed, there is a signal to the consumer control center, easy to monitor, the valve in addition to the electric node, with the ordinary valve is not much difference, there are also signal butterfly valve. When setting a quota, cover a valve, and then set 13-156.Door closer, 7-194 and 13-1013.Fire phone 7-188.Fire radio 7-382
Q:What does the butterfly valve model d344h, d345h, d346h, d347h mean?
According to the international standard of the letters and numbers apart to explain D344H D is a unit of butterfly valve, two unit 3 is driving mode: turbine, three unit 4 connection: flange connection, four unit 4 Structure: seal type linkage, five unit H sealing material: Cr13 stainless steelD345H compare yourself to the above. Unit 5 four is a sealed, single eccentric structureD346H four unit 6 is an unsealed center vertical plateD347H four unit 7 is unsealed double eccentricIn general, there is only one difference between them: the structural form is different!
Q:How to connect the signal butterfly valve?
If you mean the signal of fire water supply system, there are generally three outlets, one public, one open and one off. Fire control system signal butterfly valve is normally open, so the signal butterfly valve to open position, with a multimeter to measure the 2 lines, the 2 lines into the input module is fine.
Q:What's the difference between a clip on handle butterfly valve and a turbo butterfly valve? Where are they used?
1, the drive mode is different (handle or turbine), mainly based on the size of the valve and the opening and closing torque to decide.2. The butterfly plate of the worm valve is installed in the direction of the diameter of the pipe. In the butterfly valve body cylindrical channel, the disc shaped butterfly plate revolves around the axis, the rotation angle is 0 degrees ~90 degrees between, when rotates to 90 degrees, the valve opens the card completely.3, clip type butterfly valve is to use double headed bolts to connect the valve between the two pipe flanges, flange butterfly valve is a valve with a flange, bolt with the valve flange at both ends connected to the pipe flange.
Q:Why is the butterfly valve used for fire control?
1, this is a good question, it seems that this has not yet made a unified standard requirements, a bit confused2, personal understanding of fire water supply pipe, pipe shall be installed on the valve, because the valve is fully open all closed features of fire control system is usually required is fully open, easy management features are obvious.3, fire water supply system is also useful to butterfly valve, but mainly signal butterfly valve.The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance; two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
Q:Tight valves?
unless they have been tampered with that wouldn't be it,they usually wont tighten up on their own,i would suspect maybe a valve with a slight burn place on it that's causing that to happen or a ring causing you to loose that much compression,try adding a small amount of oil in the cylinder and then do the compression test again,that will tell you if its a ring or a valve,that's a big loss of compression ,and when you see that much of drop its usually a burnt valve.good luck.
Q:How much is the Honeywell butterfly DN300?
Find the agent or find a reliable valve plant a lot of foreign brands are in Chinese OEM so find a reliable factory is relatively good service to keep up
Q:The difference between the directly buried gate and the flange valve and butterfly valve
Buried gate also called buried gate valve, valve can be directly buried underground, built without manhole, reduce road excavation area; small well maintained road and beautiful room can reduce the difficulty of construction, reduce project cost. The directly buried soft sealing gate valve is divided into two types: telescopic type and fine fixing type, wherein, the telescopic type is divided into metal type and plastic type. In the process of construction, the telescopic type can be adjusted arbitrarily according to the distance between the buried depth of the valve and the ground, and the micro adjustment can be adjusted on the spot. The directly buried gate valve has the advantages of long-term use, no leakage, no maintenance, etc., and can effectively avoid other people switching the valve and stealing the manhole cover at will.Flange gate valve is connected to the flange gate valve, this connection is the most common way.
Q:What is the principle of butterfly valve and check valve? Any difference?
Direct water butterfly valve, check valve is to water can not flow valve

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range