Interlocked armored alloy cables armored 90 ℃XLPE insulated single

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

    WDZA-YJLHB8 is a kind of high toughness stainless steel interlocking armored 90 ℃XLPE insulated single or multiple chip low smoke halogen-free flame retardant grade cable;

    WDZA-YJLHB9 ( ZA-AC90 ( -40 ) ) is a kind of high toughness aluminum alloy at 90 ℃interlocking armored XLPE insulated single or multiple chip low smoke halogen-free flame retardant grade cable;

    Cable does not contain heavy metals, green environmental protection. The models of cables can reduce the pipeline wiring the construction difficulty and the manpower cost. The cable has been in the factory with high flexibility interlocking armored finished, requires no plumbing and accessories and artificial intensive cable, threading and pipe construction.

    This type of cable can also be applied to the humid environment of the wire or cable laying, and with the same performance of coated line pipes.

    The cable is a low smoke zero halogen type, with GB/T 12706.1 and GB/T 17650.2, IEC 60754, IEC 60502.1 standards.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the use of wire and cable per square meter of residential building?
You can use sc. if too long, or bend the best use of the bridge
Q:What is the difference between a pre-branch cable and a punched clip?
Cable bridge is used to support and protect a variety of cables, in power plants, substations, large industrial and mining enterprises, high-rise buildings are widely used. But are a one-time infrastructure in place, usually no longer replace and add.
Q:Will the two 16 square copper wire with what specifications of the trunking
WZC: W-halogen-free, ZC-flame retardant class C F46-poly perfluoro-propylene propylene Y - polyolefin sheath 2 - steel tape armor 2 - PVC outer jacket
Q:Power cable inspection, how many meters should be sampled?
meaning: ZR represents the flame retardant properties YJ said cross-linked polyethylene insulation V said PVC jacket ZR-YJV table red copper core XLPE insulated PVC sheathed power cable 4 * 70 + 1 * 35 said 4 core 70mm2 + 1 core 35mm2
Q:A sub-eight splitter, behind the link ONU equipment, which also need to add fiber patch panels, or can be directly connected?
Cabinets Half Week + Line (Horizontal + Vertical) + End Range Cabinets Half Week Long or Longer to Equipment Reserve + Quota Total Length * 2.5%
Q:PVC pipe on the GV.215-16 (C) What does it mean
SC pipe welding fluid with welded steel pipe, the general thread connection, or casing welding connection. TC pipe is a thin-walled steel pipe, referred to as wire tube, you can thread connection, tight connection, buckle type connection, not casing welding connection.
Q:Power cable casing buried what are the requirements
1 It is advisable to select the route to lay the cable in a suitable way: 1 Avoid the area where the corrosion of the acid, alkali, or stray current is seriously affected by electrochemical corrosion
Q:What is the length of the wire that affects voltage and electricity
When the cable is laid on the multi-layer bracket, the cables are arranged from top to bottom, the first layer is the high voltage cable, followed by the low voltage power cable. The control cable is placed on the lower part of the power cable. At the bottom of the instrument cable, when the low voltage power cable With the instrument cable in the same layer of laying, should be added partition isolation. Computer communication coaxial cable, full length are required to shield the use of closed trunking.
Q:How to determine whether the square of the cable is standard
Depends on your number is not arranged in order, the general building room when the patch panel and the user board number is one to one correspondence
Q:Can 110kv and 10kv cables co-share with trenches? What is the relevant specification?
According to Article 22.7.1 of the Electrical Design Code for Civil Buildings JGJ16-. the transmission lines and the electronic information system transmission lines shall be laid separately and shall be shielded when they are close to the laying of them in parallel by the construction conditions. High-voltage cable under normal circumstances is not allowed and weak cable with the ditch laying. If the relevant control cable does need to be with the high-voltage cable ditch, should be laid on both sides of the laying and keep the distance, but also pay attention to control cable shielding measures.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range