HVAC Ventilation Ducting Flexible Air Hose Pipe

Ref Price:
$1.00 - 20.00 / m
Loading Port:
Shekou
Payment Terms:
TT or LC
Min Order Qty:
100 m
Supply Capability:
100000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

HVAC Ventilation Ducting Flexible Air Hose Pipe

1.Structure of HVAC Ventilation Ducting Flexible Air Hose Pipe

Flexible air ducts are typically made of flexible plastic over a metal wire coil to shape a tube. And they have a variety of configurations. Flexible ducts are very convenient for attaching air outlets to the rigid ductwork. It is commonly attached with long zip ties or metal band claps. Besides, flexible ducts can tolerate moderate negative pressures.

2.Main Features of HVAC Ventilation Ducting Flexible Air Hose Pipe

-Applied in air conditioning/ventilation systems

-Tear and puncture resistant

-Corrosion resistant

-High flexibility

-Convenient installation

-No toxic gas emission

3. HVAC Ventilation Ducting Flexible Air Hose Pipe Images

 

HVAC Ventilation Ducting Flexible Air Hose Pipe

4. HVAC Ventilation Ducting Flexible Air Hose Pipe Specification

Insulated Flexible Duct

Structure: 1 layer of Aluminum Foil+1 layer PET film+insulated glass wool

Outer jacket: 1 layer of Aluminum Foil

Glass Wool Density: 16kg/m3; Thickness: 25mm

Insulated Acoustic Flexible Duct

Structure: 1 layer of Aluminum Foil +1 layer PET film+ insulated glass wool

Outer jacket: 1 layer of Aluminum Foil + 1 layer of PET film

Glass Wool Density: 32kg/m3; Thickness: 25mm

Specification

Type 1

Material

Aluminum foil

Structure

Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire.

Application

Suitable for medium-low air speed

Technical Parameter

Size

4”-16”

Standard Length

10m

Maximum Air Speed

20m/s

Maximum Heat Resistance

-20℃-150℃

Maximum Pressure

250mmWG

 

Type 2

Material

Aluminum foil

25mm thickness ,16kg/m3 glass wool.

Structure

Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire.

Insulating layer is covered by 25mm thickness ,16kg/m3 glass wool.

Outside layer: Reinforced aluminum foil;

Inside layer: Glass fiber mesh

Application

Suitable for medium-low air speed and low temperature difference.

 

Technical Parameter

Size

4”-5”, 6”-12”, 14”-16” 

Standard Length

7m, 10m

Maximum Air Speed

20m/s

Maximum Heat Resistance

-20℃-150℃

Maximum Pressure

250mmWG

 

Type 3

Material

·Aluminum foil

· 25mm thickness ,24kg/m3 glass wool.

Structure

· Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire.

· Insulating layer is covered by 25mm thickness ,24kg/m3 glass wool.

· Outside layer: Reinforced aluminum foil;

Inside layer: Glass fiber mesh

Application

Suitable for medium-low air speed and large temperature difference.

 Technical Parameter

Size

6”-12”

Standard Length

7m

Maximum Air Speed

20m/s

Maximum Heat Resistance

-20℃-150℃

Maximum Pressure

250mmWG

 

5.FAQ

We have organized several common questions for our clientsmay help you sincerely

1.How long for the delivery time?

Delivery time: 10-30 days, it depends on the ordered quantity.

2.What’s the usage

Practicality: suitable for the densely-populated area(such as school, supermarket, office, stadium, theater, factory.),high requirement of the environment area, such as hospital, laboratory, howff, bus, train, broadcasting studio. main usage: 1) Cold, hot water supply facilities for public buildings 2) Food, chemical, electronic industrial pipeline networks such as pipeline networks for transporting all kinds of corrosive liquid 3) Drinking water production system pipeline networks such as pure water and mineral water 4) Air conditioning facility pipeline 5) Compressed gas pipeline networks for industry 6) Pipeline network for swimming pool 7) Pipeline network for solar energy facility 8) Agriculture and garden production Additional information

How you control the quality?

During the production of fiberglass insulation, material is sampled at a number of locations in the process to maintain quality.

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:HVAC Heating: What are the main components of the air distribution system?
(HS Code) Yes, the tax rebate is 13% (April . 2009 latest data). Floor of the board of the tax number is, the tax rebate is 9% (June . 2009 the latest data), floor board is the inspection of goods, exports need to be checked. There is nothing to understand where to add me MSN: kfwdz@hotmail.com
Q:External wall insulation method of operation There are several combinations of materials
Seeking the existing building construction specifications Daquan! The The @ .com
Q:What is the whole heat exchange fresh air ventilator?
(GJG130 - Fan Jutang Duanjie Daojie Juejiao 2001) will be replaced by (GJG130-2011) is expected to begin the implementation of the construction of this year, the construction of fastener steel scaffolding safety technical specifications (GJG130), the construction of fastening steel pipe scaffolding safety technical specifications (GJG130- -2011)
Q:Air conditioning machine work when the sound is too much reason
This is based on the density of benzene board decision, not what you said, know it buddy.
Q:Air to water heater host and air conditioning host is not the same
This test with a small sample length 127mm, width 12.7mm, the maximum thickness of 3.2mm. In the absence of ventilation test chamber. The top of the specimen (6.4 mm place) is clamped with a clamp on the bracket and the longitudinal axis of the specimen is kept vertical. The lower end of the specimen is 9.5mm from the lamp tip and 305mm from the dry absorbent cotton surface. Bring the Bunsen burner and adjust it to produce a blue flame with a height of 19mm. Place the Bunsen Lights flame at the bottom of the sample for 10s, then remove the flame (at least 152mm away from the specimen) and write down the sample. Burning time. If the flame of the sample within 30s after removal of the flame is extinguished, the original lamp must be moved under the specimen again, re-ignite the sample for 10s, and then remove the Bunsen burner again and note the flame burning And flames burning the burning time. If the sample droplets drip, let it fall into the sample under the 305mm cotton, to see whether it ignited cotton. If the absorbent cotton is on fire, the rating should be taken into account. Specific grading indicators are as follows. Test Item 94V-094V-194V-21 Ten-time ignition Total flame burning time Maximum value (S) Individual flame burning time Maximum value (s) Flameless burning time (s) Yes Flame drop No No Allow only short time Burning general UL yellow card on the thickness of the test strip is divided into: 1/8 inch, 1/16 inch, 1/32 inch thickness, that is, 3.2mm, 1.6mm, 0.8mm three grades test.
Q:The installation method of ordinary air conditioner. The more detailed the better. Please thank you all
The basic operation of the same, but the different requirements of different professional, or to determine the direction of good, and then hands.
Q:Air conditioning ventilation when the sound is a big reason
Buried plastic pipe under external load, the diameter of the vertical diameter deformation rate should be less than the allowable diameter of the pipe deformation rate The diameter of the allowable diameter of the pipe shall not be greater than 5% The diameter deformation rate of the pipe and the allowable diameter deformation rate are calculated as follows: ε ΔD / D0 × 100% [ε] ε0 / K where: εΔD pipe in the combined load (Mm) [ε] Permissible diameter Deformation rate ε0 Elastic diameter Deformation rate (%) of pipe, by the flattening of the diameter of the pipe diameter (mm) The test determines the K safety factor, generally desirable 15
Q:The United States direct mail dyson hp01 Dyson air purification cooling machine triple in the country to warranty it
Among them, the extruded polystyrene gypsum composite board is based on paper gypsum substrate, the use of adhesive and extruded polystyrene board through the factory processing compound
Q:Single cold air conditioning function can not change the cold and warm?
External wall insulation should pay attention to what the details?
Q:Home 2 air conditioning is the cooling of electricity or heating electricity? How much power is spent in hours
No, polycyclic aromatic should be anthraquinone This is certainly not all of the hydrocarbons are carcinogenic

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range