Product Description:

This boiler is 698KW one.




Introduction:

The first horizontal biomass boiler in China    Brand:  HUAYUAN

High-end product---Longxiao series A, B, C


Technical features:

By the great effort, HUAYUAN has developed the first biomass boiler without grate. There are three kinds of hot water boilers as following:

Longxiao Series A: blue touchscreen control system, burning any biomass fuel without dark smoke.

Longxiao Series B: colorful touchscreen control system. motor frequency control system. drain the coked fuel in the combustion procession. burning all coked biomass fuel.

Longxiao Series C: large colorful touchscreen control system. intelligent control system, internet control system. drain the coked fuel in the combustion. burning all coked biomass fuel.

Characteristics:

1. Different from tradition vertical boiler, any parts of boiler could be checked and repaired. Even the fire pipes in the boiler could be replaced without boiler disassembled.

2. HUAYUAN adopts world leading patent combustion system. Boilers without grate will need no more grate transporting to solve coked fuel burning problem.

3. High temperature in the hearth could be controlled to make sure that temperature is enough high to do biomass pyrolysis gasification and complete combustion. With specially designed

   airflow spraying, tar will not be attached to the hearth after longtime combustion and pipes will not be blocked by the attached tar, it will do little effect on the boiler's efficiency after long                 time using, this is what users will neglect. Long-time energy saving is what matters.

4. As store is directly connected to the hearth, many biomass boilers catch fire easily. Applying anti-back fire structure and back-flow prevention device, so that only biomass fuel can be put  into hearth, high temperature airflow can't flow into bunker. We are equipped with safety fire protection device, even when the back-flow  prevention device fails, automatic monitoring feeding system will start to force high temperature into hearth. Boiler will stop working only after cleaning all the fuels.

5. Change the traditional boiler feeding way, decrease the feeding height of bunker, increase the capacity, reduce the labor strength.

6. Traditional biomass boiler only monitor output water temperature, Longxiao series adopts touchscreen control system, clients can monitor the parameters of temperature of input water, output water, smoke, fuels in bunker, combustion in hearth etc. After the change of relevant data, it will timely remind the user of maintenance, so that to allow user to get more information about running status and energy-saving data.

7. First one to apply internet control system in biomass fuel industry, you can monitor the boiler everywhere with internet.

8. Under intelligent control, boiler will automatically operates from start-running-stop-restart. You could be an online boiler operator with high efficiency and 6 safety protection settings.

Product specification:  covers from 10*104Kcal~180*104Kcal this list shows parts of specifications for reference)  

Item

Unit

CLHS0.12

CHLS0.24

CLHS0.35

CHLS0.48

CLHS0.60

CLHS0.73

Rated head

Kcal

10*104

20*104

30*104

40*104

50*104

60*104

Rated discharge pressure

Mpa

0Normal pressu re

Rated temperature of outlet water

                                         85

Rated temperature of return water

60

Heat efficiency

%

90

Water inlet

MM

40

50

50

65

65

80

Water outlet

MM

40

50

50

65

65

80

Drain hole

MM

40

50

50

65

65

80

Vent hole

MM

40

50

50

65

65

80

electricity

KW

1.1

1.5

1.8

2.2

2.7

3.2

size

length

MM

2060

2360

2560

2790

2820

3200

width

MM

650

738

850

1010

1060

1150

height

MM

1760

1760

1760

1960

1960

1960



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Ever date a bunny boiler?
Good question..Fatal Attraction was a great movie....The more modern version is Derailed...Enjoy
Q:What is the boiler cold state debugging and hot debugging?
Boiler cold commissioning: boiler body pressure test, the pressure gauge, safety valve calibration, all the boiler auxiliary commissioning operation.
Q:Why my boiler has a sulfur smell?
Was a cleaner used earlier this season? If it was serviced they add a chemical to clean rust, scaling etc has that smell. Maybe there was some still in the boiler.
Q:In the boiler, how to understand the "atmospheric pressure" and "pressure" these two concepts?
Pressure hot water boiler can supply both low temperature water, but also supply high temperature hot water.
Q:gas boiler mounting,?
you shouldn't do this your self, so ask a gas fitter
Q:The Difference between Coal - fired Boiler and Circulating Fluidized Bed Boiler in Power Plant
1) is particularly good for fuel adaptability.
Q:why do i need a boiler to make steam?
To run a turbine and produce power in any way, you need a continoues flow of high pressure steam. Just heating a pipe would not do much.
Q:Boiler before reaching máximum temperature makes sound as if turned off but still on . thanks?
All boilers are not the same so what make and model do you have? As long as there is a call for heat the circulator pump will continue to run but the burner will cycle off when it reaches the set water temp.
Q:thermostat and boiler not connecting?
With what you've described, there can be a ton of reasons why it's not working. Could be weak batteries (if so equipped). Could be a defective transmitter, or the boiler could be experiencing OTHER problems. Could be a bad control board, could be failed ignition, could be a sticking gas valve (assuming it's gas, if oil, could be a clogged filter or line). You say everything appears to be working but the boiler is not coming on. How do you know the boiler is working if nothing is coming on? Are you SURE the boiler is working properly? My advice is to have a professional look at it and diagnose the problems. But only after IF your controller is battery powered you try replacing the batteries with fresh ones. My garage door opener remote works from all the way out at the street. But when the battery gets weak the door doesn't open unless I'm a few feet away. All goes to power and transmission. So you might just need new batteries in the thermostat. But you don't say if it's battery powered, so I can only guess. Hope this helps. 'av'a g'day mate. )
Q:Swap a radiator on a combi boiler.?
Assuming you isolated the boiler before commencing work, reopen flow/return valves beneath charge the system up to 2 bar via filling loop. Bleed the towel rail and any rads. Ensure system has 1-1.5 bar in when this is done. The auto air vent on the boiler will bleed any air. Run the boiler without heat (no gas) to prevent any possible damage to heat exchanger (incase air in there). You will have to reset the boiler 3 or 4 times after the flame failure kicks in. All we want is the pump to run for a minute or so. When this is done check gauge/top up turn the gas back on underneath and you should be ok.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range