HUAYUAN high-end horizontal biomass boiler--232KW

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

This boiler is 232KW one.




Introduction:

The first horizontal biomass boiler in China    Brand:  HUAYUAN

High-end product---Longxiao series A, B, C


Technical features:

By the great effort, HUAYUAN has developed the first biomass boiler without grate. There are three kinds of hot water boilers as following:

Longxiao Series A: blue touchscreen control system, burning any biomass fuel without dark smoke.

Longxiao Series B: colorful touchscreen control system. motor frequency control system. drain the coked fuel in the combustion procession. burning all coked biomass fuel.

Longxiao Series C: large colorful touchscreen control system. intelligent control system, internet control system. drain the coked fuel in the combustion. burning all coked biomass fuel.

Characteristics:

1. Different from tradition vertical boiler, any parts of boiler could be checked and repaired. Even the fire pipes in the boiler could be replaced without boiler disassembled.

2. HUAYUAN adopts world leading patent combustion system. Boilers without grate will need no more grate transporting to solve coked fuel burning problem.

3. High temperature in the hearth could be controlled to make sure that temperature is enough high to do biomass pyrolysis gasification and complete combustion. With specially designed

   airflow spraying, tar will not be attached to the hearth after long time combustion and pipes will not be blocked by the attached tar, it will do little effect on the boiler's efficiency after long                 time using, this is what users will neglect. Long-time energy saving is what matters.

4. As store is directly connected to the hearth, many biomass boilers catch fire easily. Applying anti-back fire structure and back-flow prevention device, so that only biomass fuel can be put  into hearth, high temperature airflow can't flow into bunker. We are equipped with safety fire protection device, even when the back-flow  prevention device fails, automatic monitoring feeding system will start to force high temperature into hearth. Boiler will stop working only after cleaning all the fuels.

5. Change the traditional boiler feeding way, decrease the feeding height of bunker, increase the capacity, reduce the labor strength.

6. Traditional biomass boiler only monitor output water temperature, Longxiao series adopts touchscreen control system, clients can monitor the parameters of temperature of input water, output water, smoke, fuels in bunker, combustion in hearth etc. After the change of relevant data, it will timely remind the user of maintenance, so that to allow user to get more information about running status and energy-saving data.

7. First one to apply internet control system in biomass fuel industry, you can monitor the boiler everywhere with internet.

8. Under intelligent control, boiler will automatically operates from start-running-stop-restart. You could be an online boiler operator with high efficiency and 6 safety protection settings.

Product specification:  covers from 10*104Kcal~180*104Kcal this list shows parts of specifications for reference)  

Item

Unit

CLHS0.12

CHLS0.24

CLHS0.35

CHLS0.48

CLHS0.60

CLHS0.73

Rated head

Kcal

10*104

20*104

30*104

40*104

50*104

60*104

Rated discharge pressure

Mpa

0Normal pressu re

Rated temperature of outlet water

                                         85

Rated temperature of return water

60

Heat efficiency

%

90

Water inlet

MM

40

50

50

65

65

80

Water outlet

MM

40

50

50

65

65

80

Drain hole

MM

40

50

50

65

65

80

Vent hole

MM

40

50

50

65

65

80

electricity

KW

1.1

1.5

1.8

2.2

2.7

3.2

size

length

MM

2060

2360

2560

2790

2820

3200

width

MM

650

738

850

1010

1060

1150

height

MM

1760

1760

1760

1960

1960

1960



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:condensing boiler problems?
Read okorder.com
Q:What should I do about getting a heating company to install a new boiler heating system?
Yep they always find a problem , that is why you use a boiler system in the UK Not enough knowledge to make a better system, that warrants the Replacement of the Entire system, More Money for them, go with a forced air system , that's what we use in the USA and it will out last a boiler 6 times over,
Q:Which combi boiler should I buy?
Hi Again I thought I had basically given you an answer to this question a while ago, it is not possible to say what size of boiler you require just by you asking a question. This will require a site visit by a heating installer to take the measurements of the rooms requiring radiators, a calculation using the sizes of the windows and type of construction used in the property and how many outside walls each room has to identify what size radiators are required.I also expressed the opinion that the demands you were making on the domestic water would probably require something out of the ordinary combi boiler range with a heatbank of some sort. You will just have to get estimates from installers that can make a site visit there is no other way of getting an accurate size of boiler.
Q:Can chilling the water in a boiler remove the oxygen?
c. Heating. Chilling has no effect.
Q:i just added two baseboard radiators to the basement do i need a stronger circulator pump for the boiler?
As you have drained down the equipment you have air in the equipment. Its combating the water from circulating. What you could desire to do is shop at it and once you get one rad warm, turn it off until yet another heats up and turn that off. you have got the potential to bleed the rads each and every time. besides the incontrovertible fact that it rather is air in the pipes it is the problem. shop at it . it gets greater efficient. To instruct that it rather is the problem, the flow from the boiler would be extremely heat while the boiler turns off. if it is so ,i'm superb.
Q:can turning on a boiler after an oil tank replacement cause the relief valve to blow, or is it just a coincide?
There is no connection between the oil storage tank and the boiler pressure-relief valve under most reasonable scenarios. The only possible direct cause I might envision - and this is a stretch - would be if the oil in the tank was substantially contaminated with a much more volatile material such as gasoline or ethanol, even methanol, and so is burning much hotter than it should. This is not entirely impossible, fluids get combined and mis-combined far too often for it to be a joke. So, do check your fuel-oil for contaminants, funny smells or any unusual smells. Check for any reports in your area of others having this problem. And check with your supplier if you have a regular contract. If you purchase from a COD guy, you could be getting anything at all in your tank what with the price of fuel - and that would worry me! Otherwise, get your boiler serviced - oil-burners should be serviced and cleaned at the beginning of each season even it it seems to be running fine. This will maintain peak efficiency (and at nearly $4/gallon, this is really important) as well as make sure there are no defects or dangers. Good luck with it!
Q:how do home boilers heat your home?
It's called hot water heat. The water circulates through pipes to radiators which radiate the heat into the room. adding pipes and radiators is done with copper pipe. Probably should be done by a pro.
Q:Determining the Volume design of a model boiler ?
what okorder.com/... In such a case just keep adding tube length to the section which boils the water until you get enough mass of steam boiling- add length to the superheater if you want it hotter.
Q:Combi Boiler problem. Please Help?
on combi boilers if your water pressure runs to .750 or below it is bad for the boiler.... it can break it so as such it shuts down the and will not fire up... don't worry.. simply go to the boiler inlet tap ( you will find it where the water pipe goes into the boiler.. the cold feed) and turn it on until the gauge goes to 1.5 bar on the dial. The boiler will now fire up when hot water is demanded by tuning on the hot water tap....Don't stop there because it sound like you have a very slow water leak on one of your radiators or a pipe possibly. Have a good look you will also need to bleed your radiators and when doing so keep periodically looking at your boiler gauge as this will go down slightly when letting air out of your central heating system.. just keep re pressurising it up to 1.5 bar....that should do it Good luck
Q:Boiler 29 MW is equal to how many Dayton
MW is the hot water boiler output power (expressed in MW)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range