Hot Selling Split Air Conditioner KVA
- Loading Port:
- Shanghai/Ningbo
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 80 Units set
- Supply Capability:
- 20000 Units per Month set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
R22/R410a,
Cooling+ Heating/ Cooling Only
220-240v/50hz~60hz
Hitachi or Toshiba compressor
Mirror Finish/ Colorful Panel/ Black Color( Other color or other flower pattern also available)
Features:
1) Big LCD display
2) Ultra-quiet design
3) 24-hour timer
4) Big LCD remote controller
5) Fault self-diagnosis function
6) Efficient energy saving
7) Ultra-strong EMC
8) Sleeping mode function
9) Independent dehumidification (Dry mode)
10) Constant fan speed control
11)360-D blowing
12)PG motor
13)CE CB TUV GS etc approvaled
14)Double-muting technology
15)Auto-defrost function
16) With 3m connection copper pipe and 4m electrical cables
17) Auto-restart function
18) Galvanized outdoor casing with anti-rust layer
19) Auto-cleaning functions
20) Blue fin/ Gold fin for evaporator and condenser
Detailed specification:
Type | NSW-07 | NSW-09 | NSW-12 | NSW-18 | NSW-24 | NSW-30 | NSW-36 |
Capacity | |||||||
Cooling Capacity Btu | 7200 | 9000 | 12000 | 18000 | 24000 | 30000 | 35000 |
Heating Capacity Btu | 7600 | 9800 | 13000 | 19000 | 26400 | 32000 | 38000 |
Electricabl Parts | |||||||
Power Input (W) Cooling | 680 | 845 | 1130 | 1940 | 2655 | 3395 | 4050 |
Heating | 687 | 910 | 1190 | 1900 | 2620 | 3540 | 4200 |
Operating Current (A) Cooling | 3.02 | 3.75 | 5.02 | 8.60 | 11.77 | 15.06 | 18.00 |
Heating | 3.05 | 4.05 | 5.28 | 8.40 | 11.64 | 15.70 | 18.60 |
Performance | |||||||
EER W/W | 3.10 | 3.12 | 3.11 | 2.72 | 2.65 | 2.59 | 2.52 |
COP W/W | 3.20 | 3.15 | 3.20 | 3.05 | 2.95 | 2.65 | 2.95 |
Air Flow Volume(m3/h) Indoor | 380 | 420 | 580 | 730 | 1000 | 1300 | 1550 |
Noise Level( dBA) Indoor/Outdoor | 27/49 | 27/50 | 29/51 | 33/53 | 34/55 | 39/56 | 39/56 |
Net Dimension & Weight | |||||||
Indoor(mm) | 802x265x185 | 802x265x185 | 880x286x196 | 880x286x196 | 1095x312x195 | 1310x322x240 | 1310x322x240 |
Outdoor(mm) | 600x490x250 | 600x490x250 | 760x540x260 | 800x590x300 | 800x690x300 | 902x795x332 | 900x860x330 |
Net Weight(kg) Indoor/Outdoor | 9.5/25 | 9.5/25 | 12.5/36 | 12.5/42 | 13 /51 | 15.5 /65 | 22 /78 |
Packing Dimension& Gross Weight | |||||||
Indoor(mm) WxHxD | 860x325x255 | 860x325x255 | 935x350x270 | 935x350x270 | 1175x375x270 | 1420x440x380 | 1420x440x380 |
Outdoor(mm) WxHxD | 730x565x370 | 880x605x370 | 880x605x370 | 940x650x420 | 940x760x420 | 1030x850x430 | 1040x970x450 |
Gross Weight(kg) Indoor/Outdoor | 11,28 | 12.5,33 | 14,39 | 14,45 | 14.5,54 | 17.5,77 | 24,90 |
Applicable Area | |||||||
Applicable Area m2 | 10~16 | 14~17 | 18~22 | 26~36 | 35~47 | 50~68 | 60~78 |
Loading Quantity | |||||||
Loading Quantity 20/40/40'HC | 132/263/305 | 106/220/265 | 99/195/255 | 82/168/193 | 70/140/170 | 45/90/114 | 43/84/96 |
FAQ
Q1:Why is it important to use home air conditioner filters?
A:Without them you can clog up vital parts of the heating or cooling components that can be difficult to clean out and can cause severe damage that will be much more expensive to repair than the inconvenience of replacing a filter once a month.
Q2:What is VRF Air Conditioning System?
A:VRF air-conditioning systems owe their growing popularity to their ability to meet a wide range of requirements.
- Q:Yituo 2 how to install air conditioning
- Are you a yituo two central air conditioning? Is said to be the type suction a top. If so, should install air conditioning inside the machine, and pipe in decorating. If decorate the first, then need to breakdown point. , of course, if the installation personnel technology in place, also be ok, like the size of the air conditioning after installed do not show. Play as big as air conditioning mouth first, and then wear cooling line, four anchors in roof, in the air conditioning on, after this setup's son also don't see anything, and remember to adopt.
- Q:Household air conditioning refrigeration quality measure standard is what?
- Air conditioning refrigeration feel lack of air conditioning, detection of judgment method is very simple, switched on more than 30 minutes, indoor machine set high wind speed wind speed, with the first thermometer testing house inlet in the middle of the position, when the thermometer reading stabilized after the record. To detect indoor machine outlet in the middle of the position, when the reading of the thermometer record after stability, comparison of intake and outlet temperature should be between 10 and 12 ℃ above can be concluded that the machine belong to the normal range. If testing temperature requirements is to feel the room is not cold, should check whether the room ceiling, Windows glass area, west to the sun heat insulation is bad, the outdoor environment temperature is too high, low voltage electric and so on factors will affect the effect of air conditioning. By looking at home without the above reasons, it is possible that air conditioning causes such as lack of fluorine, should go to maintenance repair service.
- Q:My ark, the input power of 1900 w, the capacity of 5100 w, hours how much electricity???????
- 1 the refrigerating capacity of the air conditioning refrigerating capacity is equivalent to 2500 w. Little horse general is 2200 w, 1 big 1 horse general is 2800 w. Under normal circumstances (ambient temperature is not too low) air conditioning power 2200 should be a horse, which is 735 w, 0735 KWH per hour, but by the outside temperature is very low, air-conditioning outdoor opportunities outside the frost is air conditioning machine loss of heat exchange, air conditioning of COP (eer) value at this moment, to prevent this happening, air conditioning should be electric heat auxiliary function, then he will start the electricity auxiliary heat, heating wire is used to heat, to alleviate the pressure of air conditioning machine outside, to keep its not frosted highest in thermal efficiency, but it is part of the energy consumption of air conditioning is divided into two parts is the power consumption of air conditioning heating is 735 w, 2200 w, the other part is electricity auxiliary heat 1200, total power of 1935 w 1.935 KWH per hour
- Q:How to correctly use of household air conditioning pressure gauge
- General family expenses air conditioning don't have the pressure gauge, when maintenance will connect pressure gauge measurement
- Q:Can adjust indoor air conditioning circulation within the outer loop
- Household air conditioner or central air conditioning, no air outside circulation function, ventilation function is known as the fresh air system is separate, can be used with the central air conditioning and home air conditioning.
- Q:How do I calculate the cooling capacity required for my room?
- To calculate the cooling capacity required for your room, you need to determine the size of the room in square feet and consider other factors such as the insulation, the number of windows, and the number of occupants. A commonly used formula is to multiply the room's square footage by 25 BTUs (British Thermal Units) for efficient cooling. However, it is recommended to consult with a professional or use online calculators for a more accurate estimation based on your specific room characteristics.
- Q:Can an air conditioner help with allergies?
- Yes, an air conditioner can help with allergies. Air conditioners filter and circulate the air, which can help remove allergens such as pollen, dust mites, pet dander, and mold spores from the indoor environment. By reducing the amount of these allergens in the air, air conditioners can provide relief for individuals with allergies. Additionally, air conditioners help control humidity levels, which can prevent the growth of mold and mildew, further reducing allergens in the air. However, it is important to properly maintain and clean the air conditioner filters to ensure optimal performance in reducing allergens.
- Q:How to choose according to the size of air-conditioning P number?
- Master bedroom closet to remove the area is 15.5, should be based on conditions of sealed heat preservation of the room, installation of 1.25 or 1.5 of the air conditioning, suggest installation be 1.5 air conditioning refrigerating capacity 3500 w. Second bedroom closet to remove the area is 11.4, can install an air conditioning refrigerating capacity 2500 w. Of the study area is 11.5, can be installed capacity of 2500 w a air conditioning. General family expenses air conditioning according to room size, and the sealing factors such as heat preservation conditions, floor, orientation, high and low, per square meter for computing the capacity of 150-150 w air conditioning refrigerating capacity size. An air conditioning refrigerating capacity is 2500 w, suitable for about 12 square meters room use; 1.25 air conditioning refrigerating capacity is 3200 w, suitable for about 15 square meters room use; 1.5 air conditioning refrigerating capacity is 3500 w, suitable for 18 square meter or so of the room.
- Q:Can I use an air conditioner in a garage or workshop?
- Yes, you can use an air conditioner in a garage or workshop. Air conditioners are designed to cool and dehumidify the air in a given space, so they can be used in any enclosed area, including garages and workshops. However, there are a few factors to consider before installing an air conditioner in these spaces. Firstly, you need to ensure that the air conditioner has enough cooling capacity to effectively cool the size of your garage or workshop. Check the unit's BTU (British Thermal Units) rating to determine its cooling capacity and compare it to the size of the space you want to cool. If the air conditioner is too small for the area, it may struggle to cool it adequately. Secondly, you should consider the insulation of the garage or workshop. These spaces tend to have minimal insulation, which means they can quickly heat up or cool down depending on the outside temperature. Insulating the space or using weatherstripping on doors and windows can help maintain a comfortable temperature and improve the efficiency of the air conditioner. Additionally, you need to ensure that the electrical system can handle the power requirements of the air conditioner. Some garages or workshops may have limited electrical capacity, so it's important to check if the circuit can handle the load. If needed, you may have to hire an electrician to install a dedicated circuit for the air conditioner. Lastly, keep in mind that using an air conditioner in a garage or workshop can lead to increased energy consumption and higher electricity bills. It's important to use the air conditioner judiciously and consider other cooling options like fans or natural ventilation when possible. Overall, using an air conditioner in a garage or workshop is possible, but it's essential to consider the cooling capacity, insulation, electrical requirements, and energy consumption before installation.
- Q:Which master know why household air conditioning Wells, drilling Wells have what effect?
- of course, it is definitely not like some people don't understand the principle that can increase the humidity (how much water flow in, how much water will be out, didn't reduce.) it will reduce indoor humidity. All of these and conventional air conditioning. A pump is available for three hanging air conditioning or 1-2 sets cabinet air conditioning used at the same time. It is more save electricity! (3 room 4-7 hours once electricity!!) Natural air conditioning geothermal air conditioning only water pump and air conditioning fan consumes little power, can effect comparing 1:25 above is one of the most energy saving air conditioning. Shallow groundwater is close to the local average atmospheric temperature throughout the year, with warm in winter and cool in summer seasons constant temperature characteristics, almost not influenced by air temperature
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Hot Selling Split Air Conditioner KVA