• Hot-Sell Rotary Vane Vacuum Pump System 1
Hot-Sell Rotary Vane Vacuum Pump

Hot-Sell Rotary Vane Vacuum Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

All of our pumps have got CE certificate and exported to Italy,Astralia ,America,Indonesia and the kind.

◊ Application

RS Series vacuum pump is compact, light and attractive in design.  It uses the big starting torque and is specially designed for low temperature environment. It is guaranteed start normally in winter’s low temperature. It is applicable to vacuum packaging, vacuum freez

This kind of pump is widely used in food packaging, scientific research, medical treatment, electronics, chemicals, medicine and laboratory of universities and colleges.

ing, automobile reparation, gas analysis, medicine mechanism, printing mechanism and other vacuum evacuations.

◊ Technical data

Q:What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The operating pressure of the hydraulic system depends mainly on the load. Generally speaking, the working pressure of the hydraulic system means the highest working pressure of the system. If the pressure is higher than the value of the equipment, the relief valve works to relieve pressure. The actual working pressure of the hydraulic system is determined by the load, which refers to the actual pressure of the hydraulic oil and can be read directly from the pressure gauge. The pressure increases with the increase of the load. You Li's balance can know: the thrust of the cylinder = the load, the thrust of the cylinder = the working pressure of the hydraulic oil, the working area of the cylinder, the working pressure = the load / the area of the cylinder.
Q:There are second cutting, third cutting, why three times?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q:Why does the centrifugal pump close the pressure to start?
The motor power is selected according to the rated flow of shaft power points plus 15 to 25%, if the outlet valve is fully open to start, the pump flow may deviate from the amount of fixed lot, pump efficiency also reduces a lot, resulting in shaft power greater than the motor power caused by tripping even burned electric machine.
Q:Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
1) oil rotary vane vacuum pump is too low, no effect on the oil seal exhaust valve, rotary plug to refuel after large exhaust sound, and oil mist, that the level is too low, the gas can be eliminated.(2) the vacuum caused by the condensable steam pollution of oil should be changed, and new vacuum pump oil should be replaced.
Q:How many pumps does the 80cm tank use?
Mainly look at the flow of the pump, all pumps have flow signs, such as 15L/HThe above is I at random, meaning that 15 litres per hour. You should calculate the volume of your cylinder, that is, the length of the tank, the width and the height of the water surface, the unit is cm. The result is 1000, which is the volume of your fish tank
Q:What is double hydraulic pump?
[double hydraulic pump] the same drive shaft drives the rotation of two pumps, which are connected together and driven by an electric motor. The suction port of the pump is common, and the oil pressure port is separated from each other. Pump output of two shares of flow can be used alone, can also be used in parallel. This pump, a pump can play the function of two pumps. For example, there are two pumps on the loader, a pump acting as the work, a pump acting as the steering, and the double linked pump can replace the functions of the two pumps. It works by coupling the two pumps at the same time.
Q:Variable flow pumps are variable pumps
Yes. The variable pump is designed to change the flow rate
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
Direct connected pump: pump impeller installed directly on the motor shaft, it looks like a whole, relatively compact, simple installation, but the general power is relatively small (big bad processing connection, but not absolute);Non direct pump: pumps and motors are independent of each other, through the coupling torque transmission, the structure is relatively large, complex installation, to adjust the level / concentricity and so on, the general power is relatively large
Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
[suppression of pumping voltage] the general use of the installation of absorption resistance to absorb the pump voltage rise. The simplest way to control the pump voltage is to connect the DC bus with an energy consumption resistor before releasing the pump voltage.
Q:Is the centrifugal pump large or small?
NPSH is also called cavitation, cavitation is too big to be.3, pump the liquid when working in the impeller inlet will produce vapor due to a certain vacuum pressure, vaporization of the air bubbles in the liquid particle movement under the impact of erosion on the impeller, the metal surface, thus undermining the impeller and other metal, then vacuum pressure is called vaporization pressure, NPSH is excess vaporization pressure of surplus the energy position of the unit weight of the liquid in the pump suction port of. The unit with annotation, (NPSH) r with. The absorption process is necessary NPSH H: pump suction fluid allows the vacuum pump installation height is allowed, in meters.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords