• Hot Sell High Pressure Water Pump System 1
Hot Sell High Pressure Water Pump

Hot Sell High Pressure Water Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

high pressure water pump
1.CE
2.Copper wire, brass impeller
3.CNC shaft, automatic wiring machine,
4. 1y warranty

 new design and hot sell high pressure water pump    

◊ Application

Applied to pumping such liquid which is clean, no solid matter or frictional matter, low viscous, noncorrosive, non-crystallizable, chemically neutral and close to water. Such as:

1.  Tank filling

2.  Domestic water supply

3.  Water transfer

4.  Pressure boosting

5.  Irrigation

◊ Features

  1. 100%copper wire, and automatic wiring.

  2. Brass impeller

  3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and precision.

  4. CNC precision automatic lathe for smoother shaft, our owner casting factory

  5. Strict test including high-pot testing of stator coil and whole pump, outgasing test and performance test, ect

  6. New shape design with patent protection

  7. Anti-rust treatment castings and electrophoresis.

  8. 30 years experience, 1 year warranty

Q:Why is the flow of the pump too small will occur cavitation phenomenon?
This is because the impeller of the centrifugal pump rotating speed under the drive of the prime mover, when the valve opening decreases, flow rate is too low, can not be taken away by the friction heat generated by the impeller and the liquid completely, make the temperature of the liquid inside the pump. Thus causing liquid vaporization, forming cavitation. Especially in the power plant, the boiler feed pump is more remarkable. Therefore, when throttling regulation, we should set up recirculation system, increase the output flow of the pump to prevent cavitation. When the feed water rate is reduced to 1/3 of the maximum flow rate, the recirculating gate shall be opened so that the flow of the feed pump will be increased properly to ensure that the liquid temperature in the feed pump does not rise.
Q:How can the submersible pump level meter be connected?
The company actively introduce international advanced production equipment and production technology, with its strong technical force, perfect equipment conditions and rich manufacturing practice, constantly development and improvement of pump products, according to the needs of users of innovative products, stable performance, excellent quality, many products export part countries and regions
Q:Fire pump and shower pump flow head selection, high resolution.
2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
Q:What are the reasons for sealing damage of centrifugal pumps?
Three, water shortages caused by running dry grinding damage.This phenomenon is more common in mounted form inlet pressure, inlet air, air cavity pump, pump boot, high temperature operation of the mechanical seal friction at high speed, can not be cooled, check the mechanical seal, the spring tension is normal, the friction surface of charred black, rubber hard cracking.Treatment methods: exhaust the pipe and pump cavity air, replace the machine seal.Four, install too tight, observe the mechanical seal of dynamic and static ring plane, if there is serious burning phenomenon, flat black and deep traces, sealing rubber hardens, lose elasticity.This phenomenon is due to tight installation.Treatment methods: adjust the installation height, impeller installed, with a screwdriver to move the spring, the spring has a strong tension, release after the reset, there is 2-4mm moving distance can.
Q:How does the centrifugal pump pump and cut the pump?
Can not be generalized, the pump is divided into many categories, centrifugal, reciprocating, screw type, diaphragm type, and so on, the starting steps of each pump is not the same. The following is the centrifugal pump and reciprocating pump to do a simple introduction. Check the items and so on.Centrifugal pump: first open the pump inlet valve, pump exhaust, and then start the motor, slowly open the outlet valve. If it is a high speed motor or multi-stage pump, open the motor before the outlet valve slightly open.Reciprocating pump: slightly open the inlet valve of the pump, fully open the outlet valve. After starting the motor, at the fully open inlet valve.Here is a brief introduction. I hope it works for you.
Q:What is pump suction work?
Pump is mainly used to transport liquid, including water, oil, acid and alkali liquid, emulsion, suspension emulsion and liquid metal, etc., also can transport liquid, gas mixture and liquid containing suspended solids.
Q:What are the internal losses in centrifugal pumps? How did they come about?
Volume loss: loss due to leakage;3. mechanical loss
Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:What are the basic technical parameters of the pump?
The basic parameters of the pump, the basic parameters of the main performance parameters of pump are the following: first, water pump flow Q flow is the amount of liquid in the pump unit time delivery out (volume or quality). The volume of flow with Q that the unit is: m3/s, m3/h, l/s and so on. The quality of flow unit is expressed in Qm. T/h, kg/s and so on. The relationship between mass flow and volume flow is Qm= P Q density in P - liquid (kg/m3, t/m3), room temperature water P =1000kg/m3.
Q:Filter backwash pump for what use, what is the principle of work ah?
But the reverse cleaning can not completely regenerate the filter medium, or there will be some impurities remain, when the regeneration of residual impurities (pressure drop) to set the value, you need to replace the filter (filter media).

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products