Hot sale radar level transmitter made in China

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
5000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

features:
Owing to adopted advanced micro processor and special Echo processed technology,the radar level meter can be applied in any kinds of complicated working environment
False echo saving function make the meter can select the correct echo out of a large number of interfering reflections,obtained the correct measured results.

Multi process connecting method and antenna shape make CMAXS60 serial radar level meter suitable to any kinds of complicated working environment.for example:high temperature,high pressure and small dielectric constant media measurement and so on.

Adopting pulse work method can make the meter has lower transmitting power,and suitable to install into any metal or non-metal vessel,no harm to people and environment.

 

Principle:
The antenna of Radar level meter emits extreme short microwave pulse to the measured media surface and reflects to the same antenna with the speed of light,the time from emission to receiption of the signals is proportional to the level in the vessel. 
GUIDEPULS60 serial radar level meter adopted special related demodulation technology,they can correctly judge the time from emission and reception of the signals to calculate the distance between the antenna and the surface of measured media.

 

Input:

 

the antenna receive the reflected microwave and transmit to current circuit ,microprocessor processed the signal,to read out the reflected microwave from the surface of the measured media.intellectual software select the correct signal and accuracy can reach millimeter degree.the distance(D) to the measured media is proportional to the running time of the pulse(T)
D=C×T/2 C:speed of light.
empty vessel distance(E) is known,then the level(L)=E-D
Output:
By inputing empty height(E)(= zero point),full vessel height(F)(=Max.measuring range) and some applied parameters to set,applied parameters can make the meter adapting to the measured environment.corresponding to 4-20mA output.

 

When the antenna emits microwaves,there should have emission angel.the area that emited microwaves radiated between the bottom of the antenna and surface of measured media should not have barrier ,so when installing,do best to keep away of facilities in vessel,just like:ladder,limit switch,heating equipment,and bracket.when it is unable to keep away,when installing,we should do false echo saving.we should note that microwave and filling flow can not intersect.the Max. level of the media should not enter into dead zone,there is certain distance between the level meter and vessel wall.when installing,the best is to make the emission direction of the antenna is vertical to surface of measured media.when installing in the area of anti-explosion,we must abide by national installation stipulation,the housing material of the intrinsic safety type level meter is aluminum,it is suitable to install in the anti-explosion area,the housing of the meter should connect to ground.
the area from measured reference plane to the bottom of the antenna is the dead zone of the level meter(reference plane is the seal surface of thread or flange)

Power supply cable can use normal two core cable,the outside diameter should be 5...9mm to make sure to seal the inlet port of cable.if there is electromagnetic interference,use shield cable.

 

4...20mA/HART(two wire) Power supply cable can use normal two core cable
4...20mA/HART(four wire) 

 

CMAXS60 has 3 debugging methods:
1,display/debug module(programmer)
2,upper computer debugging GDPFSOFTWARE
3,HART handheld programmer
display/debug module(programmer)
Programmer is pluggable debugging tool,to debug by 4 keys,after bebugging,it is easy to read measured datas through the display screen of the programmer and display window on the meter cover.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What safety problems should we pay attention to when using electric drills and hand-held power tools?
All conducting parts must be well insulated,
Q:How are hand powered tools classified into class I, class II, class III?
Simple methods are: hand-held electric tools for metal shell for class I. The plastic case is of the type ii. Class III uses safe voltage.
Q:What's the role of carbon brushes in electric tools?
In addition to induction type AC asynchronous motors, there is no outside. Other motors are provided, as long as the rotor has a reversing ring.The principle of electric power generation is that a magnetic field cuts a wire to produce an electric current in the wire. The generator cuts the wires by rotating the magnetic field. A rotating magnetic field is a rotor, and the wire to be cut is a stator.
Q:What other tools are there for the furniture except the pistol hole?
It is mainly used in construction, decoration, furniture industry, opening for objects or objects in the past, also known as hammer in some industries.Well, there are more drilling tools on the market now.
Q:Is there an electric tool for screwing bolts? It's bolts, not screws?
Yes, electric wrench.An electric wrench is a wrench powered by a power source or battery. It is a tool for tightening bolts. It is mainly divided into impact wrench, torsional shear wrench, fixed torque wrench, angle wrench, angle spanner, hydraulic wrench, torque wrench, rechargeable electric wrench.
Q:What is the difference between a flashlight and an electric screwdriver?
A flashlight is a drilling tool powered by alternating current or direct current batteries. It is a hand-held electric tool.The main components of a drill are a drill chuck, an output shaft, a gear, a rotor, a stator, a casing, a switch and a cable.Electric torch (pistol drill) -- a tool used for drilling metal, wood, plastics, etc.. When equipped with positive and negative reverse switch and electronic speed regulating device, it can be used as electric screwdriver. Some models are equipped with rechargeable batteries, which can work normally within a certain period of time without external power supply.
Q:What power tools are used as cage birds?
An electric drill or a small bench drill, drill speed is the best because of the speed change drill, drill hole spacing and easy consumption. If you want to do with special accessories can also change the distribution of wood milling, milling machine, special safety and easy to do.
Q:What is the working principle of power tools?
AC motor, AC motor of induction motor, its strong induction current (eddy current) magnetic field generated in the rotation of the magnetic force on the rotor copper bar, continuous cutting, according to Lenz's law, the induced current has the effect of relative motion occurs against the rotor magnetic field and the rotor is, with the magnetic field and rotation. But the rotor rotation speed of the high speed magnetic field does not transform, otherwise it will not be able to cut the copper lines.
Q:How about plug wires and cables for power tools?
Class II tools, that is, insulated structures, all double insulated power tools. The specified voltage is over 50V, and the grounding device is not allowed in class II tools. Generally insulated enclosures. Generally speaking, the design of II tools made use of personal protective equipment operator to some reliable method in the tool, the tool has a double protective current, guarantee in the fault state, when the basic insulation failure, insulation and reinforced insulation provided by additional electric shock protection.
Q:Why hand grinding sand turbine, electric drill, impact drill and other power tools plug is two, plug is not three plug
In recent years, leakage protection performance and the reliability greatly, has become a standard power supply, reliability of human protection over ground protection to a certain extent, but the impact of grounding protection and leakage protection to human body protection, so many hand-held electric tools to cancel the earthing protection, relying instead on leakage protector. And use the two eye plug.Look at the instructions for the hand-held power tools with two plugs. All require that the power supply be equipped with an electric leakage protector.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range