Hot Dipped Galvanzied Razor Wire Galvanized Black Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Item specifice
Product Description:
1.Hot Dipped Galvanzied Razor Wire Galvanized Iron Wire Black Wire Description:
Galvanized Iron Wire has the characteristics of thick zinc coating, good corrosion resistance, firm zinc coating, etc.
Galvanized Iron Wire mainly used in construction, express way fencing, binding of flowers and wire mesh weaving. Galvanized iron wire according to manufacturing technique, it includes hot-dipped galvanized iron wire and electro galvanized iron wire. Mainly telecommunication equipment and materials, medical equipment and device, weaving of wire mesh, steel rope, and filtration mesh, high-pressure pipe, construction, arts and crafts.
2.Main Features of Hot Dipped Galvanzied Razor Wire Galvanized Iron Wire Black Wire:
• Razor Wire Variety:
Concertina Coils Type
Straight Type Razor Wire
mainly serves in protecting of grass boundary,railway,highway and also widely used in military,jail,industry,agriculture,animal husbandry,dwelling house,plantation for fencing.
3. Hot Dipped Galvanzied Razor Wire Galvanized Iron Wire Black Wire Images
4.Hot Dipped Galvanzied Razor Wire Galvanized Iron Wire Black Wire Specification
Reference | Blade Style | Thickness | Wire | Blade | Blade | Blade |
BTO-12 | 0.5±0.05 | 2.5mm±0.1 | 10mm±1 | 13mm±1 | 26mm±1 | |
BTO-18 | 0.5±0.05 | 2.5mm±0.1 | 10mm±1 | 13mm±1 | 26mm±1 | |
BTO-22 | 0.5±0.05 | 2.5mm±0.1 | 20mm±1 | 15mm±1 | 33mm±1 | |
BTO-28 | 0.5±0.05 | 2.5mm±0.1 | 15mm±1 | 15mm±1 | 33mm±1 | |
BTO-30 | 0.5±0.05 | 2.5mm±0.1 | 22mm±1 | 16mm±1 | 36mm±1 | |
CBT-65 | 0.6±0.05 | 2.5mm±0.1 | 60mm±2 | 22mm±1 | 102mm± |
Outer diameter | No.of Loops | Standard Length per Coil | Type | Notes |
450mm | 33 | 7M-8M | CBT-65 | Single coil |
500mm | 41 | 10M | CBT-65 | Single coil |
700mm | 41 | 10M | CBT-65 | Single coil |
960mm | 54 | 11M-15M | CBT-65 | Single coil |
500mm | 102 | 15M-18M | BTO-12.18.22.28.30 | Cross type |
600mm | 86 | 13M-16M | BTO-12.18.22.28.30 | Cross type |
700mm | 72 | 12M-15M | BTO-12.18.22.28.30 | Cross type |
800mm | 64 | 13M-15M | BTO-12.18.22.28.30 | Cross type |
960mm | 52 | 12M-15M | BTO-12.18.22.28.30 | Cross type |
The Length and the diameter of the coil can be designed as per the customers'request.
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your Hot Dipped Galvanzied Razor Wire Galvanized Iron Wire Black Wire?
One of the most biggest manufacturer & supplier of wires and wire mesh,is a large-scale professional UAE Market Electric Galvanised Wire BWG 20 0.7mm Hot Dipped Galvnised Wire factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements.
②What is your Technical Information of Hot Dipped Galvanzied Razor Wire Galvanized Iron Wire Black Wire?
1).Material: super carbon steel
2).Processing by drawing, hot-dip zinc-plating
3).Standard wire gauge from 8# to 24#
4).Thick zinc-coating layer
5).Super in corrosion resistance
6).Firm coating layer
7).Custom size available
10 to 15g Zinc Coating and 35kg Tensile Strength Iron Wire Electro Galvanized Iron Wire
③How long can we receive the product after payment?
In the purchase of Galvanized Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served。
Hot Dipped Galvanzied Razor Wire Galvanized Iron Wire Black Wire
- Q:Wire runs from breakers to a wall outlet along the garage wall
- Ok so the first two answers are almost correct. If the breaker is 20amp it's 12 gauge wire, if it's 15 amps it will be 14 gauge wire. The outlet is in a garage it must be a GFCI receptacle. That's a national electrical code requirement. If the wiring is to be exposed (ie not inside of a wall) then it must be in conduit, cheapest and easiest to install is pvc, you can run romex or NMB through conduit. If the wall is to be sheetrock when finished then you can run just romex through the studs. It is recommended that the GFCI receptacle be mounted in an extra deep box but is not required, makes it easier to get it in there with the wires. You can put up to 8 receptacles or devices, like light fixtures on one 20 amp circuit. More and you will be over loading the circuit. The romex you run should be for 20 amp 12-2 with ground. All circuits and devices must be grounded to be in compliance.
- Q:For my braces, the top wire where my two front teeth are, I can push the wire and it sort of bend. I don't know if this is normal or not. Can someone tell me?
- Well im 16 and have had my wire braces for 2 years, and all my neighbors have wired braces, but i believe the invisible braces ive seen appear dangerous, like they have somthing on they are tooth. At the least with wired braces everybody knows its braces and no longer some crap you've got on you tooth thats suposed to be invisible.
- Q:is it safe to use twist on wire connector to connect my new stereo or should i crimp instead?
- I would suppose in this case there is a good better best way to do it. IMO I would never do twists on a stereo, at the very least, do butt connectors. Best way would be to solder each wire one by one and seal with heat shrink. That will give you a very clean look and you'll be proud of yourself :)
- Q:What is the wiring for one headlight on a fourwheeler that has high and low beams.
- Year? Make? Model# ? If it has 1 headlight with a high low beam, the bulb has 2 filaments.
- Q:The wire on my headphones were cut clean off in the middle of the wire. Is there any way it can be fixed? I tried to find out other ways but it seems one of the only ways is to strip the wire of its covering. Is there a way to fix it without burning the wires?
- I totally agree with Mr. Smith. However, I would use heat shrink tubing for a neater look than the tape.
- Q:Can I run a 10 gauge 2 wire plus ground from a double pole 30 amp breaker to a dryer that uses 240v? I need to know if the one black wire will be sufficient or if i need to get a 2 hot one neutral wire.
- You can use the 10/3 wire, but you wire it so that the black and the white are hot wires and the ground is the neutral. Of course you won't have the bare ground to use as a ground anymore, so if you want it wired with a bare ground to the cabinet, you will need to run a separate bare ground. Or get different wire with a red a black a white and a bare ground. Red and black will be hot, white will be neutral and bare ground will be ground.
- Q:tryin to move dryer approx 8 more feet but existing wire not long enough have 12/2 wire can that be used to run 220 dryer
- The answer is probably NO. You can not safely use 12/2 wire to run a 220 volt dryer. 12 ga wire is only rated for 20 amps. Electric dryers are 30 amps and utilize a 2 pole breaker, so you would need to use 10/3. If your dryer is a gas dryer and only runs on 120 volts then yes you can junction 12/2 to 12/2 and extend the run the remaining 8 feet (as long as that run isn't more than about 200 feet long already). If you don't know what you are doing then just don't experiment with electricity, you can burn your house down.
- Q:I know that most wire is copper, however, I found this wire that is silver in color. So that got me to thinking, what other metals are used in wire, and, are they all non-magnetic?
- It depends a little on how you define electrical wire but if you mean any wire that is used to conduct electricity even if it is not used specifically for wiring houses or electronics. So... No, some electrical wire, electrical resistance wire for example, is magnetic. Iron is not the only wire that is magnetic, Ni wire is made and it is magnetic, stainless steel wire is made and some stainless steels are magnetic.
- Q:THERMOSTAT WIRING
- Connect the red wire to the R terminal on the t-stat, connect the white wire to the W terminal, connect the green wire to the G terminal and connect the blue wire to the Y terminal on the t-stat. The B terminal is not used on most thermostats. Unfortunately most manufacturers of thermostat wire do not make 4-wire with a yellow wire and instead make it with a blue wire, that is why they don't match up perfectly. The red wire provides 24v power from the furnace, the white wire controls the call for heat from the t-stat, the green wire controls the fan, and the blue wire/yellow terminal controls the air conditioner.
- Q:I need to buy more of the speaker wire my Yamaha system came with. Its very very thin almost clear wire. What is it called and where can i get it?
- Short answer is that it is called speaker wire. Most speaker wire supplied with a general-purpose audio or home theater system is 16 or 18 gauge wire (the lower the gauge number, the thicker the wire). Most general-purpose speaker wire is very inexpensive for even a 100ft spool. If you really don't know what you are looking for and just want to match what you have, the easiest thing to do is bring a small sample of your current wire to a store like RadioShack or the electrical section at Lowe's or Home Depot and match it up yourself with what they have available. Chances are you'll find a match in under a minute. You can also just order a spool of name-brand 16 gauge wire online from places like OKorder or Best Buy also.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Hot Dipped Galvanzied Razor Wire Galvanized Black Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products