Hot Dip Galvanized Iron Wires For Chainlink Fencing

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Commercial Galvanized Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:installing ceiling fan, 4 wires?
Look in the box where the switch is installed. Is there a black wire that also has a wire nut on it? If so, someone used a little forethought when they ran the wires to this switch. You will connect one of the wires (red or black, doesn't matter which) to the black wire of the fan, and the other goes to the blue wire of the light kit on the fan. Then connect the white to white, and the ground wire goes to the mounting bracket or bare copper wire of the fan. At the switch box, you will need to add another switch for the fan. If there is only room for 1 switch, you can buy a combination fan/light switch that fits in the space of 1 switch, but has controls for both the fan and the light. Hope this helps.
Q:2x Red Wire and 1x Black Wires Coming Out Of Wall... Which Wires Are Which?
In the uk red was live and black was neutral, is this part of multiple wall lights ? then it should be only one red is live, the other may go to another light fitting. The light fitting would possibly be red=live, blue=neutral and green is earth, I say possibly because it is a mix of old colours and new. There should be installation instructions with it. Start by connecting one red to the light fitting red and the black to the blue connect the earth, make the other red safe and switch on. If that doesn't work change the wall red to the other and try again. If everything is working and no other lights are not working then make good and leave as is, otherwise you may need to connect all reds together for the other light to work. You may be able to identify the live red if it is a single with grey insulation cable.
Q:wiring receptacle in bedroom?
A 15 Amp receptacle will work, of course, but the receptacle box is most likely already overfilled. So in order to keep the wire count down, your best way to go is to buy a receptacle that uses screw down connector tabs. (NOT the kind that you have to put the wire under the screw, but the kind that you insert the wire into the back and then turn the screw down to clamp onto it!) The receptacle is a little more money but it would be worth the expense to make this hook up work. Hot wire (Black): Connect all three black wires to the back of the receptacle on the brass colored screws. Common wire (White): Connect all three white wires to the back of the receptacle on the silver colored screw. Ground: make a short pigtail of bare copper wire (about 6 or 7 inches long). Then connect the pigtail to the other 3 bare copper ground wires using a wire nut. Then connect the other end of the pigtail to the grounding connection of the receptacle. MAKE SURE THE POWER IS OFF WHEN YOU DO ALL OF THIS SO THAT YOU CAN LIVE TO TELL THE TALE! :-)
Q:how to wire a dirt bike coil?
The two small wires are positive and negative. Most are color coded and if it's a OEM part, the negative will be the same color as the group of smaller wires connected to the negative battery cable. Each manufacturer uses different color codes and for instance, Kawasaki uses black with yellow stripe. The other wire will go to the positive side. If the coil doesn't have wire coming out if it, it may have a + or - sign by the terminals. In actuality, it doesn't really matter which way you hook it up because a coil doesn't really care which way the electricity travels. It's the collapsing magnetic field that creates the spark and not the direction or movement of electricity.
Q:does copper, bell, or speaker wire carry energy faster?
If he is an Electrician than my guess is that the wire is solid copper (not stranded). While this will technically work, it is not very flexible and it would be single wire which could mean getting the polarity (+ and -) easily confused. Save yourself the headache and just buy some 12 gauge stranded speaker wire. (It's not that expensive).
Q:How to wire honeywell visionpro IAQ?
from the thermostat you match 1,2,3 wires to the module, from the module to the furnace. - R to R (this is your 24V hot) W to W (furnace 24V input G to G (fan for cooling 24V input) Y to Y (cooling 24V input), there should also be another wire that connects with this that goes to the condensing unit C to C ( Common - must have this connected for IAQ to work) as with the Y, there should be another wire to connect to this that goes to the condensing unit. - maybe W2 to W2 if you have a 2 stage furnace, you'll know if you have a 2 stage furnace because the W2 connection on the furnace will be present. - maybe Y2, if you have 2-stage cooling. if you have a humidifier connect both wires from the humidifier selinoid valve to each of the HUM terminals.
Q:airsoft upgrade wires?
I think it prevents the wires from overheating and melting the insulation which could lead to a short.
Q:why use steel wire in building construction?
What burns in a building are mostly the furnishings and interior, not the frame it's made of. Steel buildings are more expensive to insure against fire than wood frame buildings, because in a fire more steel is damaged by warping and distortion than would happen in a wood-framed structure, and wood structures are easier (and cheaper) to repair. Of course, if everything in a building was non-flammable, fire would never occur. That doesn't usually happen, though, and it's all the flammable stuff that most buildings house inside that burns.
Q:How do I wire my Phone Lines?
(links just for reference, from search engine results)
Q:color code for wires in a 2000 ford explorer?
Radio Constant 12V+ Wire: Light Green/Purple Radio Switched 12V+ Wire: Yellow/Black Radio Ground Wire: Black Radio Illumination Wire: Red/Black Radio Dimmer Wire: N/A Radio Antenna Trigger Wire: N/A Radio Amp Trigger Wire: N/A Front Speakers Size: N/A Front Speakers Location: N/A Left Front Speaker Wire (+): Orange/Light Green Left Front Speaker Wire (-): Light Blue/White Right Front Speaker Wire (+): White/Light Green Right Front Speaker Wire (-): Green/Orange Rear Speakers Size: N/A Rear Speakers Location: N/A Left Rear Speaker Wire (+): Tan/Yellow Left Rear Speaker Wire (-): Gray/Light Blue Right Rear Speaker Wire (+): Orange/Red Right Rear Speaker Wire (-): Brown/Pink You match the wires from your new unit to the wires of the harness.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range