Product Description:

Packaging Detail:standard export plywood case
Delivery Detail:15-20days

Specifications

1,Single-stage single-suction 
2,Axial suction centrifugal pump 
3,Back-pull-out design

Min inlet pressure

Min inlet pressure depends on NPSH +0.5m safety margin + gasified pressure. It should be re-calculated the inlet pressure if one of the following happens.

*The liquid is more warm.

*The flow exceeds the nominate value.

*Suction distnace is very long or inlet pipe is very long.

*System pressure is too little.

*Inlet pressure is low.

 

Typical application

*Clean, thin, non-corrosive, non-flammable or non-explosive liquid without grain or fiber.

*Water supply system

*Heat, air condition system

*Irrigating, farming

*Booster, constant pressure water supply

*Industry cooling, heater circulation system

*Firefighting, splitting system

*Industry transferring, drainage system

 

Construction

*Non-self-priming, single stage, single suction, horizontal, axial suction and radical discharge, pump body is fixed by base.

*Use bering cradle, which can orientate bearing, prevent from radical vibration, improve the rigidity of rotary part.

*Compacted shaft, use deep grove grease lubricated roller bearing.

*Connect pump and motro with semi-flexible coupling.

*Use standard wearable mechanical seal.

*TEFC motor, size complies to IEC standard, installation type B3.

*The dimensions is conform to ISO 2858

 

Specificaton

*Flow: Max 520m3/h

*Power:Max 160Kw

*Head: Max 160m

*Liquid temperature: -15°C - 110°C

*Working pressure: Max 16bar

*Inlet and Outlet diameter: Inlet diameter: DN50-DN200; Outlet diameter: DN32-DN150

 

Curve conditions

*Curves tolerance is according to ISO9906, Annex A;

*All curves are based on the measured value of constant motor speed 2900rpm, 2950rpm, 1450rpm or 1480rpm.

*The measurements were made with airless water at temperature of 20°C. The curves apply to a kinematic vis-cosity of 1 mm2/s (1 cst)

 

Features

*Back-pull-out design, without having to disurb pump body and pipelines when servicing.

*All the models only use 4 kinds of pump shafts and bearing cover, make parts exchangeable.

*Impeller is optimum design, inlet is enlarged, no whirlpool, deduct the water pump NPSH efficiently, which makes pump work stable with little noise.

*Casing and casing cover use wearing neck ring structure, which makes pump easy to maintain, makes parts work longer. The replaceable seal ring, makes pump work efficiently in a long time.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Attention should be paid to the use of pumps?
To carefully check whether there is a crack impeller, impeller fixed in the bearings are loose, if there are cracks and loose, hungry phenomenon should be promptly repaired, if the pump impeller above the soil should also be cleaned
Q:Pump operator's responsibility Sharing the rules, responsibilities, etc..
3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
Q:Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
(1) the disk, stator or bushing is worn and shall be inspected, trimmed or replaced with a rotary vane vacuum pump.(2) the pump temperature is too high, which not only reduces the viscosity of the oil, increases the saturated vapor pressure, but also may cause cracking of the pump oil. Ventilation, cooling and environmental temperature should be improved. If the exhaust gas temperature is too high, should be cooled before entering the pump, the environment temperature is high, should try to use a better high speed vacuum pump oil or 3# diffusion pump oil. (10) because of the deformation, wear or movement of the parts, the maximum opening height of the check head can be reduced or even unable to be opened, the intake of oil is too little, and the vacuum degree of the rotary vane vacuum pump is reduced, and should be adjusted as shown in the assembly section. Open high, more oil, but open too high, check valve in some places on the stop, it will not automatically drop, lost to prevent oil returns. The commonly used rotary vane vacuum pumps mainly include double stage rotary vane vacuum pump and single-stage rotary vane vacuum pump
Q:The water tank of the fish tank does not air out and only has the water outlet
The water pump is cut off, the intake pipe is drawn out, and the water in the air pipe is blown out, then the water pump is put on the surface of the water, and the air inlet pipe is inserted on the surface of the water pipe, and then the water pump is put back into the water, and the water pump is electrified. Try again several times at a time. It should be effective.
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same
Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Q:What does the impeller on the centrifugal pump mean by the first cutting?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
(1) the pellet dose in the safety standard of the infusion pump refers to the amount of liquid that is transported to the patient in a short period of time(two) pill dose limit is mainly to control the risk of accidental pill dosage. Especially after the mandatory requirements of pipe blockage in the elastic pipe storage liquid limit amount of agglomeration and the limitation of these methods to release pill dose.
Q:How to calculate the motor power of metering pump?
Two Hydraulic power, metering pump rated flow (L/H) X, maximum pressure (Barg) / 36000 = kw
Q:Suction stroke and lift of water pump
The absorption process is also called the "largest self-priming height" (also can be understood as "the degree of self suction). Micro pumps do not add water at the circumstances, can automatically water suction pump up the maximum height (the vertical distance from the pump to be pumped from the mouth of pumping liquid).Generally lower than the water pump positioned equal when there is self-priming pump required capacity. For example, outdoor tourism, need to extract the water in the river, with the best micro pump self-priming ability (impossible to people ran to the river water inlet pipe with water. It) or pumping the liquid corrosion, easy to add water and so on occasions.
Q:What are the parts of a pump? How do you classify it?I just want to know
According to the working principle can be divided into: centrifugal type and volume type centrifugal pump. By the centrifugal force of the impeller will accelerate the refrigerant, through to stay, so as to achieve the purpose of boosting; volume by changing the refrigerant in the flow volume to boost purpose.According to the media and installation conditions, water pump: centrifugal pump used: the impeller pump shaft, a curved blade on the impeller impeller outlet. The central entrance water vertically along the tangential direction of axial flow pump: high speed, large flow, low lift, mixed flow pump and centrifugal pump structure similar to that of the blade outlet angle is different, wide flow channel, close to the performance of axial flow pump displacement pump: safety valve must be opened before the start (metering pump, screw pump)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range