Horizontal Centrifugal Water Pump for Agriculture Application

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 Centrifugal Water Pump for Agriculture Application

1.Structure of  Centrifugal Water Pump Description

 

Centrifugal Water Pump is used for transporting pure water or liquids with physical and chemical  properties similar to pure water, and the maximum of the medium temperature is 80°C.(type ISR pump reaches 120°C). Widely applied towater supply industry, urban water supply and drainage, metallurgy, power stations, textile, chemical industry, printing and dyeing, ceramics, rubber, heating, waste heat utilization, air conditioning, agricultural irrigation and etc.

 

2.Main Features of the Centrifugal Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. Centrifugal Water Pump images

Horizontal Centrifugal Water Pump for Agriculture Application

4. Centrifugal Water Pump Specification

 

Item

Diesel Water Pump

Diesel Pump

Agricultural Irrigation Desel Water Pump

Model

IS

Material

Cast iron

Mode

Horizontal

Color

Blue and adjustable

Theory

Centrifugal Pump

Structure

Single-stage Pump

Usage

water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Diesel

Pressure

High Pressure

Application

Transporting pure water or liquids

Outlet Diameter

32-250mm

Capacity

6.3-400m3/h

Head

5-125m

Rotation Speed

1450-2900r/min

Power

0.55-110kW

Warrenty

1 Year

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
(1) the disk, stator or bushing is worn and shall be inspected, trimmed or replaced with a rotary vane vacuum pump.(2) the pump temperature is too high, which not only reduces the viscosity of the oil, increases the saturated vapor pressure, but also may cause cracking of the pump oil. Ventilation, cooling and environmental temperature should be improved. If the exhaust gas temperature is too high, should be cooled before entering the pump, the environment temperature is high, should try to use a better high speed vacuum pump oil or 3# diffusion pump oil. (10) because of the deformation, wear or movement of the parts, the maximum opening height of the check head can be reduced or even unable to be opened, the intake of oil is too little, and the vacuum degree of the rotary vane vacuum pump is reduced, and should be adjusted as shown in the assembly section. Open high, more oil, but open too high, check valve in some places on the stop, it will not automatically drop, lost to prevent oil returns. The commonly used rotary vane vacuum pumps mainly include double stage rotary vane vacuum pump and single-stage rotary vane vacuum pump
Q:Advantages and disadvantages of canned pumps
The ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and rotor drive. The structure eliminates the rotary shaft sealing device of the traditional centrifugal pump, so the utility model can be completely free from leakage.
Q:Must the water pump in the tank be all soaked in water?
Of course, if the motor is overheated, it will burn, and the temperature of the water will drop down.
Q:What is the pump delivery? What's the difference between years and years?
First of all, as a student majoring in insurance, I strongly condemn the first floor of ignoring practice and trampling on real knowledge!!The insurance industry criticized a lot, but it is required for many people, we should face and try to maintain the healthy development of the industry, the first floor of the insurance you have not done, have no contact with the insurance, insurance, not to dictate the nonsense, more should not be here misleading!
Q:What should be used to pay attention to the use of mechanical pumps?
There are many kinds of pumps, such as centrifugal pumps, piston pumps, diaphragm pumps, vane pumps, gear pumps, etc.
Q:What is the difference between an air pump and a water pump?
A pump is a machine that transports liquids or pumps liquids. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids.
Q:Why is the sewage pump device coupler?
2. automatic coupling device of the sewage pump coupling device has compact structure and small occupation area. Because the sewage pump is submerged, it can be installed directly in the sewage tank, and no special pump room is needed to install the pump and pump. It can save a lot of land and infrastructure costs.
Q:What are the starting and stopping procedures for centrifugal pumps?
The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
Q:Rules for operation of centrifugal pumps
Working principle and process flowWorking principle: when the drive motor with high-speed rotating impeller, full of fluid in the pump body under the action of centrifugal force, was thrown from the impeller center to the outer edge of the impeller, in this process, the fluid energy, improve the pressure can, at the same time also increases the energy flow rate increase. The liquid from entering the pump impeller shell, the liquid flow gradually widened, the liquid velocity decreased gradually, which will be part of the kinetic energy into pressure energy, which further improves the static pressure of liquid, and liquid with high pressure in pressure pipeline. When the liquid from the leaves out when the impeller center creates pressure and low pressure than the out plane is big, under pressure drive, liquid is continuously from the center of the impeller suction, with the pressure of continuous discharge.
Q:The main factors affecting the performance of centrifugal pumps
The low specific speed pump, on the other hand, is suitable for smaller flow and higher lift. When the pump outlet pipe diameter at the same time, if the two pumps flow similar, smaller than the speed of small head, shaft power consumption is also large. Generally speaking, the centrifugal pump with smaller revolutions than the impeller has a narrow outlet width and a large outer diameter, and the channel formed by the blade is narrow and long. If the ratio of revolutions is large, the impeller outlet is wide and the outer diameter is small, then the flow passage is short and wide.I hope my answer will be helpful to you. I hope to adopt it!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range