Hong Rui Long distance multiplexer communication fiber optic cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:


Brand Name:


Model Number:

HRDV-16VZ1DF-2

Type:

communication fiber optic cable

Certificates:

CE/FCC/RoHs

Audio Channel:

Forward/ Reverse Audio

Fiber Mode:

single mode or multi mode

Video Interface:

BNC

Video input/output impedance:

75ohm(unbalanced)

Working Temperature:

-30 C ~ +75 C

Video Channel:

16 channel

Video Digital Bit Width:

8/10 bit

Input Rating Voltage:

AC220V/50Hz





Packaging & Delivery

Packaging Detail:Carton lined with pearl cotton
Delivery Detail:3-7 working days after payment

Specifications

communication fiber optic cable 
1. Manufacturer, factory price 
2. In stock, fast shipping 
3. CE/FCC/RoHS 
4. OEM service

 

long distance multiplexer communication fiber optic cable features

 

1. 8-bit or 10-bit digitally encoded and non-compression video transmission

2. Directly compatible with NTSC, PAL and SECAM CCTV camera systems and support RS-232, RS-422

    and RS-482 data protocols

3. Power supply and other parameter state indication, which can monitor the operation condition of system

4. Support no-damage regenerative trunk of video

5. Constant input optical power, and large dynamic range, no electrical or optical adjustments required

6. Special ASIC design

7. Industry-grade of operating temperature from 10 to 75, which is applied to the different working environment

8. Hot-swap function

9. Stand-alone type or card-type installed in 19" 2U or 4U rack-mount chassis

10. Optical interface: FC, ST, SC(optional)

11. Abundant signal interface, such as video, data, audio, telephone, Ethernet, binary input/ output and talkback

 

* Application

 

1. City traffic monitoring system 

2. Police and safe city monitoring system 

3. High way security protection and toll station system 

4. Building and campus monitoring system 

5. Industrial monitoring(airport, chemical plant, steel, oil, railway, irrigation works, mine and so on) 

6. Military monitoring(storage, frontier defense, guard, national defense and so on) 

7. Electronic power oil field, TV station program broadcasting system 

8. Gymnasium (live video and audio transmission)

 

* Order Information

 

Part No

Description of product

Transmission Distance

HRDV-16VZ-2

Multimode and 16 CH video

0-2KM

HRDV-16VZ-20/40/60/80

Single mode and 416 CH video

0-80KM

HRDV-16VZ1DF-2

Multimode and 16 CH video + 1 CH reverse data    

0-2KM

HRDV-16VZ1DF-20/40/60/80

Single mode and 16 CH video + 1 CH reverse data 

0-80KM

 

Special Specification: Video+Data+Audio+Ethernet+Phone+Alarm, Long transmission distance.

Our Multi-function products have competitive price! Can be customized according to your personal requirements !

 

* Accessories in the package

 

User Manual

maintenance card

Qualified Certification

Power Adapter

Device

1 copy

1 copy

1 copy

1 pcs

 

1 pair

 

 

* Video Feature

 

Video Interface: BNC
Video input/output impedance: 75Ω (unbalanced)
Video input/output Voltage: 1VP - P (peak value),Max 1.2Vpp
Video Bandwidth: 10MHz
Video sampling: 15MHz high speed sampling
Video digit bit width: 10 bit
Differential gain: ( 10%-90%APL) DG <1%( Typical value)
Differential phase: ( 10%-90%APL) DP <0.8°( Typical value)
Video SNR: S/N ≥ 70dB (Maximum optical link path loss)

 

* Audio Features

 

Audio interface: Forward Direction, Reverse Direction or Bi-directional Audio
Interface terminal: standard industrial connecting terminals or lotus terminals
Audio input/output electric level typical: 0dBm
Audio input/output impedance: 600Ω (balanced/unbalanced)
Audio input/output amplitude: 2VP-P(peak value)
Audio bandwidth: 20Hz~20kHz
Sample rate: 58.6K
Nonlinear distortion coefficient: ≤ 1 %
Audio SNR: S/N≥85db

 

* Data Features


Interface:standard industrial connecting terminals
Controlling Equipments: PTZ decoder, Keyboard ,data interface of Matrix, High speed dome camera, industrial equipments
Interface Signals: RS-485(2 lines),RS232,RS422 and so on


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a kbg threading pipe and a PVC threading pipe?
You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!
Q:The computer can not open the machine display frequency beyond the scope of the mouse and keyboard do not start can not press F8 how to do
Then you get the repair station to see what is the problem
Q:Now the market professional installation monitoring the construction team how much money a point? , As well as cable patch panels and telephone patch panels how much money a point? Is it distance?
I think it is possible, because in our (old) substation, the cable trench is the drain, the cable erected in the cable bracket.
Q:Buy Taipower c 450P with remote control to add audio and video cable
And I answered the other person's question is very similar: . the line of the banding distance of not more than 1.2 meters, the two ends of the wire box outlet tube 15CM should be ligation; . casing embedded, then through the basement wall, the surface must be installed rigid Waterproof casing, that is, steel pipe + water ring; through the fire pool, living pool: flexible waterproof casing; (wing ring specific practices can be collected online related Atlas); through the floor, according to whether the design requirements , Under normal circumstances PVC casing on it. Note: . rigid waterproof casing, flexible waterproof casing is a one-time reserved in place, through the floor of the casing of the flower lamb to suppress the barge of Xi Jie Xi Xi shou, is the first stay hole, when the installation of riser Casing, because the floor casing has every layer, the location of the reservation will always be biased, in order to ensure vertical vertical pipe, and finally unified hanging line repair hole and then install the riser and casing. . now most of the bathroom are dirty, waste and diversion, and more of the riser, and so on, the air conditioning casing of all the shear wall should be embedded, to avoid the subsequent damage to the structure of drilling (no stay can only drill) Note that the location of the hole and the installation of the riser will affect the opening of the toilet window. . the casing is the casing, riser is the riser, casing than the riser model 1 to 2 level. . plate at the end of flat, board 2 to 5CM higher to see if you need to do leveling layer.
Q:2.5 square copper (green, with the threading tube) can withstand the highest power of several kilowatts,
The electrical part of the decoration is laid by the electrician, as long as you tell him the power of your home and the equipment used, the electrician will tell you how much to buy the large diameter line, and the number and color needed.
Q:Help look at such a configuration will not have compatibility issues! Do you need to improve? Budget in 5500 or so
What do you want to do? Do network cabling buried? Or in the building after the tube?
Q:What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
Q:Seeking the basement of the outer wall piercing the cable after the casing, how to solve the water (200 points online)
To be considered is the Great Wall power line is not long enough, the power is not big enough to see the power on the label, if the 12V to 15A or more I think will be more stable, my Dell machine power cord surprisingly short, but also To buy the extension line again.
Q:What does the letter of the computer cable model mean?
(The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )
Q:Is there a difference between PE cable and PE water supply pipe?
Rubber over the bridge surface curing treatment, nice and at the same time to ensure a safe Pressure tonnage: 5 tons to 65 tons, indoor and outdoor are available (and provide only tramway) Uses: used in engineering department exhibition company, power company construction line, play a role in protecting the line Rubber trough ■ tough, insulated, high pressure (maximum load of 65 tons) rubber over the bridge ■ suitable for all outdoor weather, rain, lightning, moisture, flame retardant ■ surface non-slip surface texture ■ Position protection to the type of cable and communication data cable ■ unique design, no need to destroy the ground installation ■ durable, the surface of non-slip surface texture ■ simple installation, easy to move, structural design briefs practical ■ unique elbow, tee, Selection ■ 1 hole, 2 holes, 3 holes, 4 holes, 5 holes design, fully applicable to the exhibition, performing arts, workshops, power, communications, military and other industries 2 Specifications Table 1 Specifications 1000 × 130 × 20 aperture 40 × 13 Weight 12KG (for indoor cable signal line, etc) 2 Specifications 1000 × 275 × 40 aperture 105 × 30 Weight 32KG (for indoor wiring too thick if the wire, etc) 3 Specifications 1000 × 250 × 50 aperture 32 × 35 Weight 7KG (applicable Over motor vehicles and large trucks, etc) 4 Specifications 900 × 500 × 75 Aperture 50 × 60 Weight 19KG (for motor vehicles and forklifts, etc) 5 Specifications 900 × 500 × 75 Aperture 32 × 35 Weight 21KG (for the workshop workshop, such as truck ) 6 Specifications 900 × 620 × 110 Aperture 90 × 90 weight The amount of 28KG (for small trucks and large trucks, etc) 7 specifications 1000 × 310 × 55 aperture 35 × 35 weight 15KG (for workshop workshop forklift or private cars, etc) 8 specifications 770 × 485 × 65 aperture 40 × 40 weight 18KG For the workshop workshop plant forklift, etc)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range