High-Voltage XLPE Insulated power cable

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

1.up to 35kV available,factory direct sales
2. 20 years experience
3.OEM available provided

XLPE/PVC Insulated Power Cable  China Factory Supplier

Cable Construction

PVC Cable:

Cu(Al)/PVC/PVC Cable

Cu(AL)/PVC/SWA/PVC Cable

Cu(AL)/PVC/AWA/PVC Cable

Cu(Al)/PVC/STA/PVC Cable

XLPE Cable:

Cu(Al)/XLPE/PVC Cable

Cu(AL)/XLPE/SWA/PVC Cable

Cu(AL)/XLPE/AWA/PVC Cable

Cu(Al)/XLPE/STA/PVC Cable

Standard: IEC60502;BS5467:1997 with Amendment 1

Conductor: Soft annealed stranded copper wires to BS6360, class 2, concentrically stranded in successive layers, in opposite direction, to form the stranded conductor. Aluminum also available

Insulation:The conductor are insulated with a layer of extruded XLPE/PVC compound.

Filling:The assembled cable is filled with a layer of PVC compound in order to fill the interstices between the cores and render the cable round.

Armoring: Consists of single layer of Steel Tape/Galvanized steel wires of appropriate size.

Sheathing: An outer protection of extruded PVC compound is applied over the armor.

Voltage rating: 0.6/1kV,3.6/6kV;6/10KV;8.7/15KV;12/20KV;18/20KV;19/33KV;21/35KV;26/35KV

Operating temperature:

90 continuous normal operation, 130 for emergency overload condition and 250 for short circuit condition

Application:

For outdoor and indoor installations in damp and wet locations, laid direct in the ground where excessive mechanical stresses are present in sloping and moving terrains and in vertical or inclined laying, as well as in locations susceptible to sliding.

   

The data sheets below show partial  Type,Name and Application of  XLPE Insulated Power Cable:

Type Name

Application

Cu

Conductor

Al

Conductor

YJV

YJY

YJLV

YJLV

XLPE Insulated,PVC or PE S heathed Power CableFor laying in door,tunnel,channel and underground.Unable to bear external mechanical force,but bear the traction force during laid.

YJV22

YJV23

YJLV22

YJLV23

XLPE Insulated,Steel Tape Armoured,PVC or PE Sheathed Power Cable

For laying in tunels in door,tunnel,channel and underground.Able to bear external mechanical force,but unable to bear large pulling force.

YJV32

YJV33

YJLV32

YJLV33

XLPE Insulated,Fine Steel Wire Armoured,PVC or PE Sheathed Power Cable

For laying in shaft with large difference of level.Able to bear external mechanical force,and moderable pulling force.

YJV42

YJV43

YJLV42

YJLV43

XLPE Insulate,Thick Steel Wire Armoured,PVC or PE Sheathed Power Cable
Able to bear positive pressure and pulling force.

Packing:

  • In rolls for cables with cross section<10mm, wooden or iron drums for heavy cable in large quantity.

  • As per client's special request.

Our advantage:

  • 20 years professional experience since 1993

  • Better competitive price and standard quality.

  • Experienced engineering team work, latest tech R&D in cables.

  • Standardized qulity control and operation system under ISO9001-2008

  • Market-oriented management, OEM acceptable.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:W22 in the cable on behalf of what
Is the name of the vv22 it is armored copper core PVC insulated power cable V is PVC, VV said PVC insulated PVC sheathed, insulation and sheath is two different things, the jacket is the outermost layer of the cable, Insulation, mainly from the role of protection cable, the insulation layer is wrapped in the conductor outside the layer, mainly from the insulation. 22 means armored, armored between the sheath layer and the insulation between the strip, and its role is to strengthen the protection of the cable, at the same time, can prevent the mouse bite, can also be used as ground. The copper core is not shown in the letter in the model, because most cables are copper, so the copper cable basically takes its representation (indicated by T). On the contrary, if it is aluminum core cable, it will be added in the model L said aluminum core.
Q:How to convert the computer's audio and video to cable TV signals. Through the cable television transmission to the 40 TV (hurry)
Fire paint is esterified by epoxy resin plant acid, respectively, with iron oxide red, iron oxide black, zinc yellow and other pigments and physical paint grinding, and adding driers, to, butanol modulation
Q:Why does the AC welding machine burn out the equipment?
Electric workers in the wood when the wood bar, buried in the soil that part of the first use of fire char, and then brush into the ground after the bitumen
Q:Pvc threading tube packaging film how to do attractive, on the grade it? Thank you great god
ZR-KVVRP-500 is mainly used for transmission control, measurement signals and other cables. ZR: Control cable KVVRP: PVC insulation 500: Rated voltage 500 V or less 1 × 2: Two core 1.5: Wire diameter
Q:Brief description of the difference between cable and cable.
Optical fiber (optical fiber) is designed to meet the optical, mechanical or environmental performance specifications, it is used in the jacketed jacket in one or more optical fiber as a transmission medium and can be used alone or in groups of communication cable Component. Fiber optic cable is mainly composed of optical fiber (such as the hair of the glass) and plastic protective casing and plastic skin, the cable without gold, silver, copper and aluminum and other metals, generally no recovery value. Fiber optic cable is a certain number of optical fiber in accordance with a certain way to form a cable core, outsourcing jacket, and some also cover the outer cover, used to achieve optical signal transmission of a communication line. That is, a fiber formed by a certain process by an optical fiber (optical transmission carrier). The basic structure of the cable is generally composed of cable core, reinforced steel wire, filler and jacket and other parts, and also need to have waterproof layer, buffer layer, insulated metal wire and other components. A cable is usually a rope of similar rope made of several or several sets of wires (at least two in each group), each of which is insulated from each other and often twisted around a center with a height Insulated cover. Cable with internal power, external insulation characteristics. Category cables are power cables, control cables, compensating cables, shielded cables, high temperature cables, computer cables, signal cables, coaxial cables, fire-resistant cables, marine cables, mining cables, aluminum cables and so on. They are composed of single or multi-strand wire and insulation layer, used to connect the circuit, electrical appliances and so on.
Q:How to find the phone number on the 110 patch panel
Cable ends should be marked with cable head symbols, the middle line should also be different from the ordinary wiring. Bv at the beginning of the general wire, with YJV or vv is generally a cable, but not limited to these
Q:30 on the large number of cable how to fight on the 110 patch panel, how to order, please inform, thank you, which
Is the size of the power cord size, that is, the thickness of the power line diameter, 4 square power cord diameter is 2.2 mm thick, the safety current between about 25-32A, that is, can withstand electrical power at 5500 watts or .000 watts Depends on the laying of the power cord, that is, the laying of dark lines or laying the line, the size of the safe current is not the same. Generally more than 2 air-conditioning use 2.5 square copper wire, 2 or more air conditioning should use 4 square copper wire.
Q:What is the length of the wire that affects voltage and electricity
When the cable is laid on the multi-layer bracket, the cables are arranged from top to bottom, the first layer is the high voltage cable, followed by the low voltage power cable. The control cable is placed on the lower part of the power cable. At the bottom of the instrument cable, when the low voltage power cable With the instrument cable in the same layer of laying, should be added partition isolation. Computer communication coaxial cable, full length are required to shield the use of closed trunking.
Q:Dell laptop plug in the power supply usb can not be used, how is it?
KVV is the control cable, generally do industrial control; and RVS is twisted pair, generally used for weak system, to eliminate the interference requirements of the occasion, such as two-wire bus system, specifically, the electrical fire bus more Such as RS485 bus and so on.
Q:What is the difference between public relations firms and media companies?
Is the separator divides the bridge into 2 and a half, usually with two different roles of the cable at the same time laying in a cable bridge, such as the power cable with the signal cable with the bridge laying, in order to avoid electromagnetic interference, with separator separation.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range