High Voltage Mining Cable 0.3/0.5kV,0.38/.066kV,1.9/3.3kV,3.6/6kV,6/10kV

 

Description

 

1、           Rated voltage of  the cables is divided into 6 grades,which is  0.3/0.5kV,0.38/.066kV,1.9/3.3kV,3.6/6kV,6/10kV.

2、           There are allowed  long-term working temperatures of the cable conductor. Fro the cable of  U(M)CPT-0.66/1.14, U(M)CPJB-0.66/1.14, U(M)CPJR-0.66/1.14 and 1.9/3.3kV,  3.6/6kV, 6/10kV, the temperature is 90℃;for the other,it is 65℃。

3、           Minimum bending  radius:for the cable of U(M)CPJB-0.66/1.14,  U(M)CPJR-0.66/1.14,it is 15 times of the cable  diameter; for the others,it is 6 times of the cable diameters.

4、           The grouding wire should be well  connected with the earth.

5、           The cable should be prevented from  exposing to the sunshine for a long time.

 

Implemented Standard

1、          For the noe-spread combustion  cable,implement GB12972 《Flexible rubber mining  cable》

2、           For the flame-retardant  cable,implement MT818《Flame-retardant cable  used in the coal mine》

3、           For the special mining cable(with  bigger cross-section and higher voltage),implement the enterprise  standard.

 

Specification

 

Type

Description

Application

MC-0.38/0.66

Rubber flexible cable for  excavator

As the power connection used in the  excavator or similar equipments with rated voltage  0.38/0.66kV

MCP-0.38/0.66

Shielded,rubber-sheathed  flexible cable for excavator

As the  power connection used in the excavator or similar equipments with rated voltage  0.38/0.66kV

MCP-0.66/1.14

Shielded,rubber  flexible cable for excavator

As the  power connection used in the excavator or similar equipments with rated voltage  0.38/0.66kV

MCPJB-0.66/1.14

Shielded  ,monitoring and braiding reinforced type,rubber flexible cable for  excavator

As the  power connection used in the excavator or similar equioments with rated voltage  0.66/1.14kV,it can be draged directly

MCPJR-0.66/1.14

Shielded  ,monitoring and braiding reinforced type,rubber flexible cable for  excavator

As the  power connection used in the excavator or similar equioments with rated voltage  0.66/1.14kV,it must be used in the protective chain panel

MCPT-0.66/1.14

Metallic  shielded rubber flexible cable for excavator

As the  power connection used in the excavator or similar equioments with rated voltage  0.66/1.14kV

MCP-1.9/3.3

Shielded  rubber flexible cable for excavator

As the power connection used in the excavator or similar equioments with  rated voltage 1.9/3.3kV

MCPT-1.9/3.3

Metallic  shielded rubber flexible cable for excavator

As the  power connection used in the excavator or similar equioments with rated voltage  1.9/3.3kV

MCPTJ-0.66/1.14

MCPTJ-1.9/3.3

Metallic  shielded,moitoring type, rubber flexible cable for excavator

As the  power connection used in the excavator or similar equioments with rated voltage  1.9/3.3kV

MY-0.38/0.66

Movable  rubber flexible cable for mining

As the  power connection used in the mining machine with rated voltage  1.9/3.3kV

MYP-0.38/0.66

Movable  shield rubber flexible cable for mining

As the  power connection used in the mining machine with rated voltage  0.38/0.66kV

MYP-0.66/1.14

Movable  shield rubber flexible cable for mining

As the  power connection used in the mining machine with rated voltage  0.66/1.14kV

MYPJ-3.6/6

Monitoring  movable shield rubber flexible cable for mining

As the  power connection used in the mining transfomer and similar equipments  with rated  voltage3.6/6kV

MYPTJ-3.6/6

Metallic  shielded monitoring type movable rubber flexible cable

As the  power connection used in the mining transfomer and similar equipments  with rated  voltage3.6/6kV

MYP-3.6/6

Movable  shield rubber flexible cable for mining

Mining equipments with rated voltge  3.6/6kV the  min.enviroment temperature is -20℃

MYPT-3.6/6

Movable  metallic shield rubber flexible cable for mining

Mining equipments with rated voltge  3.6/6kV the  min.enviroment temperature is -20℃

MYPD-3.6/6

Movable  shield rubber flexible cable for mining

Mining equipments with rated voltge  3.6/6kV the  min.enviroment temperature is  -40℃

MYPTD-3.6/6

Movable  metallic shield rubber flexible cable for mining

Mining equipments with rated voltge  3.6/6kV the  min.enviroment temperature is  -40℃

MZ-0.3/0.5

Driller  cable for mining

As the  power connection of driller with rated voltage 0.3/0.5kV

MZP-0.3/0.5

Driller  shielded cable for mining

As the  power connection of driller with rated voltage 0.3/0.5kV

MYQ-0.3/0.5

Movable  light-type rubber flexible cable for mining

Lighting in  the mine,as the power connection of the interlock and control signals used in  the transport machine and equipments

Notes: According to the customer’s requirements,we can  design and manufacture all kinds of rubber mining cables, with bigger  cross-section,higher voltage(10,15kV),double-color sheath used in the mining  machines and equipments,including the machines and equipment from England and  Germany.

 

Picture

High Voltage Mining Cable 0.3/0.5kV,0.38/.066kV,1.9/3.3kV,3.6/6kV,6/10kV.

Q:I have a very old computer tower without the fat monitor. (which i through away years ago) I have some pictures on it that i would like to extract, but i don't know how to. And i lost the power cable to the tower. I would appreciate if you could help me. Thanks
Any power cable from any computer or normal monitor will work. Boot the computer, copy the files to a flash drive or external hard drive, and then plug the new one back in and copy the files from the drive. If it's REALLY old (doesn't even have USB ports), then the easiest way may be to open the tower, remove the hard drive, and plug it in with an IDE to USB adapter (you can buy one online, or see if a computer shop has one). Make sure you find one with a power source.
Q:if I buy a new 4 pronged power cable how should i install in the dryer,what should i do with the extra 4th wire of the cable,pls help Thanks
not a problem, just find a screw near the wire on the outside of dryer, and if not one make one,and then screw wire onto it...It will just be ground wire..........just make sure that you have right wires goint to the correct places...........
Q:I have a USB powered external hard drive. The cable that came with it has to plug-ins for the PC. I know the fat one provides power so I use that one. I would like to know what the other skinny one is for.I have seen other people plug both in when using it and it worked fine for them. I am using just the fat one and it works fine for me. I would just like to know the reason for having both on a cable.
Two sizes are the same connections, standard and mini. Use whichever fits your computer.
Q:summary of why 'power cables' are bad evidence. what happens to people whose whole life has been living close to power lines?
Well, before 1977 the United States had massed produced electrical powerlines which used PCB's, or PolyChlorinated Biphenols. They were chains of of chlorine, used as insulators in powerlines. They get into the air and the people are sick around them at a certain period of exposure. They give people really bad acne and it gets into water underground and many other ways of infection are possible (even eating food around a powerline outside. However, many of the powerlines you see now are younger than 1977, but if you see any powerlines that you suspect are extremely old or at least 30 years old, and you believe it has PCB's and are worried it is infecting the area of environment... You should call FEMA or some sort of environmental pickup specialists or something. How do I know all this? Selected research, I believe my area may have a large amount of ground PCB levels.
Q:I have a Belkin Tune Cast II FM transmitter. The fuse in the DC car power cable is .5 A but it blows every time I plug it in. What is the correct fuse to use for this charger?
If you know that's the correct fuse. You might have another problem such as the wires are shorting or grounding each other out and not completing the circuit. It might just be best to buy a new transmitter instead of wasting your money on fuses.
Q:I'm trying to run a cable and power outlet into a closet for a media space but im not sure how to add the outlets in there. The area where the closet is, is on a wall that has no outlets and behind the closet is a bathroom which has no outlets on that side of the wall either so theres nothing to tap into. please help.thank you.
What's under and over the closet? If the basement (unfinished is best for tapping into and no worries of going through multiple walls) is under it, you may have a bunch of choices to tap into. Make a list of what circuit breaker/fuse every light, outlet, appliance is on, you don't want to overload a already full circuit.
Q:It's not the original power cable but it's going to my current DVR.
The cable will work just fine.
Q:I have a Maxtor 3200 and I accidentally plug in the wrong power cable for it. I saw the light flicker on then off. I realized my mistake and tried to plug it in its correct cable but now it won't turn on at all. I figure that the wrong cable must of forced too much energy through it. I have a lot of important files on there. I know that fixing it won't be cheap, I fully realize that. However, is there any hope of retrieving my files at all?
sond a thugh blown it but if you take it to a store and see if they can recover the data of the platters, you may get lucky if you get the right people?
Q:I want to hook up (charge) my iphone AND my radar on my motorcycle. My radar is already wired to the 12v cable in my bike. Now can I hook up the iphone to the same cable? or is it gonna be drawing too much power? thxI was planning on buying the cigarrete lighter thing, and pluging the iphone into that. I'd obviously hook up the cig lighter to the 12v cable.
Basically no, they are better wired separately unless you calculate the load. A ciggy lighter socket is not water proof so find a proper bike socket. BMW do them, You need to work out what the total load of these 2 are, and check the output of your alternator and the capacity of your battery to make sure you have enough ''spare'' power. What make of bike is it? What's the battery capacity and the output from the alternator. Electrics on modern bikes are usually good enough for accessories, I run 100w headlight 2 x 50w spots, sat nat phone and audio, not always all together, so do some sums on what power you have otherwise if it's only a small battery and alternator you could run the battery own whilst riding.
Q:is there any way to fix this? i don't want to upgrade my power thingy though.
Did the cardboard incorporate a cable that has a huge and small white connector on one end and a huge connector on the different? Or a small connector on one end and a extensive 4pin connector on the different end? If it did, connect the small connector to the small 4 pin interface connection on the lower back of the cardboard and hook the means suppy to the different end of the cardboard. This ingredients the voltage mandatory to run the fan, you pick this for cooling.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products