High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:


Brand Name:


Model Number:

Submarine Fiber Optic Cable

Type:

Cat 1

Number of Conductors:

4

Application:

Telecommunication

Product Name:

Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

Outer Sheath:

Asphalt sheath

Communication application:

Underwater

Fiber Count:

2~144 Cores

Fiber type:

G652D, G655, G657, Ala(50/125),Alb(62.5/125)

Tube:

Aluminum tube

Armored:

Steel armored

Inner sheath:

PE sheath



Packaging & Delivery

Packaging Detail:High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable 1.Wooden drums with test report. 2.2000m-6000m/roll,roll wide 40cm-100cm, diameter 50cm-160cm. 3.Calculation for 20ft or 40ft containers.
Delivery Detail:3~7 working days in general for Submarine Fiber Optic Cable

Specifications

Communication Use Underwater Direct Buried Submarine Fiber Optic Cable 
Steel Wire As Center Strengther Member 
Anti-corrosion

High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable            

Product Description

  The fibers, either of single-mode or multi-mode type, are placed in a aluminum tube. The tubes are filled with a water-resistant filling compound. A steel wire sometimes sheathed with polyethylene(PE) for cable with hight fiber count,locates in the center of core as a metallic strength member. Tubes(and fillers) are stranded around the strength member into a compact and circular cable core. An Aluminum Polyethylene Laminate(APL) is applied around the cable core,which is filled with the filling compound to protect it from water ingress.Then the cable core is covered with a thin PE inner sheath. After the single-steel armored, the cable is finally completed with an outer sheath.

 

Characteristics:

1. Accurate fiber excess length ensures good mechanical and temperature performance.

2. Single-steel ensures good performance of tensile strength

3. High strength loose tube that is hydrolysis resistant and special tube filling compound ensure a critical protection of fiber.

4. Specially designed compact structure is good at preventing loose tubes from shrinking

5. Crush resistance and flexibility

6. The following measures are taken to ensure the cable watertight:

7.Steel wire used as the central strength member

8.Loose tube filling compound

9.100% cable core filling

10.APL moisture barrier

11.Water blocking material

Other Picture Show High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic CableHigh Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

 High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

 

 

 

Technical Parameters

 

Total number of fiber cores

2-114

Outer diameter (mm)

13-24

Cable Max unit weight (kg/km)

200-450

Allowable pull force (N)

long-term

1500

short-term

3000

Allowable crush strength (N/100mm)

long-term

1500

short-term

3000

Min bending radius (mm)

static

12.5 times of cable external diameter

dynamic

25 times of cable external diameter

Application of temperature

-40°C-70°C

 

 Note:      

1. Cables can be supplied with a range of single mode or multimode fibers.
2. Specially designed Cable structure is available on request.   


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a kbg threading pipe and a PVC threading pipe?
You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!
Q:Ipad charging display does not support this accessory
Ipad charge display does not support the general reasons for this and processing methods: . for non-original charger, it will often appear this situation, which is due to the charger does not meet the specifications caused by the replacement of a qualified charger can be. . if the original charger appears the above failure, please continue to look down. . please check whether the data line is normal. The appearance of the data lines seem normal, which may have been broken. Check the method is to borrow someone else's data line to see if it can charge. . shows the plug symbol is normal is full of display. If full or show the lack of electricity, indicating that the phone tail no problem. . again, check whether the original charger can work properly. You can connect the charger to other USB port to see if the phone is working properly. . if the above two check still can not charge, please try to insert the computer's USB port to see if the computer can identify the phone, to identify if it is to see if the charge, if not identified but not charged, it is estimated that the need for maintenance. If you can not identify can not charge, it is necessary to repair. If you can recognize and charge, replace the data cable and the charger (the original estimate is also damaged). . and then look at the voltage is not too low, not only to the maintenance station to repair, and pay attention to the iPad and iPhone do not mix the power adapter, the voltage is different.
Q:How to distinguish between power cables and electrical wiring on drawings
Can not be removed, and so on after the first line of fluoride, and then demolition of air conditioning.
Q:The computer can not open the machine display frequency beyond the scope of the mouse and keyboard do not start can not press F8 how to do
According to the "Power Engineering Cable Design Code" GB-. 5.3.3 only asked for the depth of the cable buried directly: drop the blue skin to the ground depth, not less than 0.7 meters; when located in the roadway or farmland Under the appropriate should be deepened, and should not be less than 1.0 meters. 5.4.3 protected pipe buried in the ground, should meet the requirements under the depth of the pressure and environmental corrosion resistance. Through the uneven settlement of the backfill section and other places to increase the force, it is appropriate to use steel. Another direct burial should be selected armor type.
Q:What is the difference between wires and cables?
The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
Q:When pouring concrete is how to put the tube
Line pipe is poured before the concrete is laid on the cloth, fixed on the template or steel, pouring a need to install a class at any time to adjust its position!
Q:Building decoration wiring pipe elbow with yellow wax tube can you?
The control cable transfers the electrical energy from the power distribution point to the power supply lines of the various electrical equipment The rated voltage of the power cable is generally 06 / 1kV and above, the control cable is mainly 450 / 750V The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick
Q:A five-hole dual-socket how to connect the wiring, the electrician line to go three lines, the switch can use a single socket did not take their own hands
Bookstore tool book should have "communication project budget", I do is what you say, the budget is divided into estimates and budget, is two steps. So that is not very clear. But what is needed is the preliminary design of the project. The budget is needed for design and drawings. Internal management of this piece, the main thing is that you need to do what the project department, and are generally very complicated
Q:Wire pipe inlet air switch trip how to do?
Wire pipe water problem: In fact, this problem is very serious, then this line should be scrapped or replaced, if you continue to reluctantly use not only to bring you the safety of trouble and the insulation of the wire dropped sharply! Because there is water it will lead to internal leakage can also make the wire heat caused by wire burning and trivial trivial accident, so be sure to take the necessary replacement! Supplement: the wire out of all, with the wire to grab the absorbent gauze and the like back to the twitching, many times for the gauze to dry the water, hair dryer toward the tube to heat the tube to dry and then re-layout of the new line.
Q:Automotive wiring harness welding to pay attention to what the problem
When the lighting circuit and the power circuit shared ladder, BV line is not allowed to put in the ladder, so it is recommended to use the wiring of the lamp ZC-YJV-3 * 2

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range