High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:


Brand Name:


Model Number:

Submarine Fiber Optic Cable

Type:

Cat 1

Number of Conductors:

4

Application:

Telecommunication

Product Name:

Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

Outer Sheath:

Asphalt sheath

Communication application:

Underwater

Fiber Count:

2~144 Cores

Fiber type:

G652D, G655, G657, Ala(50/125),Alb(62.5/125)

Tube:

Aluminum tube

Armored:

Steel armored

Inner sheath:

PE sheath



Packaging & Delivery

Packaging Detail:High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable 1.Wooden drums with test report. 2.2000m-6000m/roll,roll wide 40cm-100cm, diameter 50cm-160cm. 3.Calculation for 20ft or 40ft containers.
Delivery Detail:3~7 working days in general for Submarine Fiber Optic Cable

Specifications

Communication Use Underwater Direct Buried Submarine Fiber Optic Cable 
Steel Wire As Center Strengther Member 
Anti-corrosion

High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable            

Product Description

  The fibers, either of single-mode or multi-mode type, are placed in a aluminum tube. The tubes are filled with a water-resistant filling compound. A steel wire sometimes sheathed with polyethylene(PE) for cable with hight fiber count,locates in the center of core as a metallic strength member. Tubes(and fillers) are stranded around the strength member into a compact and circular cable core. An Aluminum Polyethylene Laminate(APL) is applied around the cable core,which is filled with the filling compound to protect it from water ingress.Then the cable core is covered with a thin PE inner sheath. After the single-steel armored, the cable is finally completed with an outer sheath.

 

Characteristics:

1. Accurate fiber excess length ensures good mechanical and temperature performance.

2. Single-steel ensures good performance of tensile strength

3. High strength loose tube that is hydrolysis resistant and special tube filling compound ensure a critical protection of fiber.

4. Specially designed compact structure is good at preventing loose tubes from shrinking

5. Crush resistance and flexibility

6. The following measures are taken to ensure the cable watertight:

7.Steel wire used as the central strength member

8.Loose tube filling compound

9.100% cable core filling

10.APL moisture barrier

11.Water blocking material

Other Picture Show High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic CableHigh Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

 High Quality Communication Use Underwater Direct Buried Submarine Fiber Optic Cable

 

 

 

Technical Parameters

 

Total number of fiber cores

2-114

Outer diameter (mm)

13-24

Cable Max unit weight (kg/km)

200-450

Allowable pull force (N)

long-term

1500

short-term

3000

Allowable crush strength (N/100mm)

long-term

1500

short-term

3000

Min bending radius (mm)

static

12.5 times of cable external diameter

dynamic

25 times of cable external diameter

Application of temperature

-40°C-70°C

 

 Note:      

1. Cables can be supplied with a range of single mode or multimode fibers.
2. Specially designed Cable structure is available on request.   


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Now the market professional installation monitoring the construction team how much money a point? , As well as cable patch panels and telephone patch panels how much money a point? Is it distance?
About 140 PVC threading tube, which depends on how many lines you row. PPR cold / hot water pipe 42 meters, PPR cold / hot water pipe with 4 m / root and 6 m / root of the points, short will make the joints more recommended to use long, generally longer expensive. Decoration in meters to count, to facilitate the settlement of labor, 42 meters is the amount of my home My house 115 square meters, indoor area of 98 square meters. I hope useful to you. According to the 2011 price, the general brand of wires and pipes, their own materials to buy, without artificial about 4000-5000 yuan. I decorated last year, the package to the decorating company hydropower workers with me to calculate the 9800 yuan it, of course, each region has a price difference.
Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
At the same time, security monitoring line itself is a weak line
Q:What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
Q:When pouring concrete is how to put the tube
Pouring concrete when you can line? Do you clear the problem?
Q:Ipad charging display does not support this accessory
Ipad charge display does not support the general reasons for this and processing methods: . for non-original charger, it will often appear this situation, which is due to the charger does not meet the specifications caused by the replacement of a qualified charger can be. . if the original charger appears the above failure, please continue to look down. . please check whether the data line is normal. The appearance of the data lines seem normal, which may have been broken. Check the method is to borrow someone else's data line to see if it can charge. . shows the plug symbol is normal is full of display. If full or show the lack of electricity, indicating that the phone tail no problem. . again, check whether the original charger can work properly. You can connect the charger to other USB port to see if the phone is working properly. . if the above two check still can not charge, please try to insert the computer's USB port to see if the computer can identify the phone, to identify if it is to see if the charge, if not identified but not charged, it is estimated that the need for maintenance. If you can not identify can not charge, it is necessary to repair. If you can recognize and charge, replace the data cable and the charger (the original estimate is also damaged). . and then look at the voltage is not too low, not only to the maintenance station to repair, and pay attention to the iPad and iPhone do not mix the power adapter, the voltage is different.
Q:Wire printed on the word what way to erase
Pro, please buy in the hardware store turpentine wipe, a bottle of 3.5
Q:How are various wire and cable models named?
Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
Q:Home leaked, installed in the floor below the wire was blisters will have any security risks? How can the water inside the pipe to dry
Megohmmeter, such as measuring insulation normal, that is, induction power, the other line after grounding, the pen measured no electricity.
Q:Automotive wiring harness welding to pay attention to what the problem
When the lighting circuit and the power circuit shared ladder, BV line is not allowed to put in the ladder, so it is recommended to use the wiring of the lamp ZC-YJV-3 * 2
Q:A five-hole dual-socket how to connect the wiring, the electrician line to go three lines, the switch can use a single socket did not take their own hands
This is too difficult to give you a way to just try: with a fine wire rope, that is, lift the clothes on the stick so thick, the end of a bend, with a tape wrapped around the head, try can not wear, wear When the possibility of rotating wire rope, if you can go through the success of the half, the key is to use the wire through the more difficult, can only use the cord, hard-line 100% make life difficult.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range